Characterization and evaluation of extended defects in CZT crystals for gamma-ray detectors

被引:53
|
作者
Bolotnikov, A. E. [1 ]
Camarda, G. S. [1 ]
Cui, Y. [1 ]
Yang, G. [1 ]
Hossain, A. [1 ]
Kim, K. [1 ]
James, R. B. [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
Defects; Volume defects; Radiation; Semiconducting materials; TE INCLUSIONS; CDZNTE; PERFORMANCE; GROWTH; CHARGE;
D O I
10.1016/j.jcrysgro.2013.01.048
中图分类号
O7 [晶体学];
学科分类号
0702 ; 070205 ; 0703 ; 080501 ;
摘要
Material homogeneity is critical in achieving high-performance in all types of radiation detectors. This requirement is not inevitably satisfied in today's commercial detector-grade CdZnTe (CZT) material because it contains high concentrations of extended defects, in particular, Te inclusions, dislocation networks, and twin- and subgrain-boundaries that affect the energy resolution and the efficiency of the devices. Defects, such as grain boundaries and cracks that completely block charge-carrier transport are impermissible in CZT radiation-detectors at concentrations exceeding certain threshold values. Our group in Brookhaven National Laboratory (BNL) conducts systematic studies, detailing the roles of crystal defects in CZT detectors and the mechanisms underlying their formation and effects. We employ infrared transmission microscopy, white beam X-ray diffraction topography, and high-spatial-resolution X-ray response mapping to identify particular types of defects and reveal their relationship with the devices' performances. In this article, we summarize some of the most important results that our group obtained over the past 5 years. Published by Elsevier B.V.
引用
收藏
页码:46 / 56
页数:11
相关论文
共 50 条
  • [1] Defects in CZT crystals and their relationship to gamma-ray detector performance
    Burger, A
    Chattopadhyay, K
    Chen, H
    Ma, X
    Ndap, JO
    Schieber, M
    Schlesinger, TE
    Yao, HW
    Erickson, J
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 586 - 590
  • [2] Characterization of CZT Materials for X-ray and Gamma-ray Detectors
    Hossain, A.
    Bolotnikov, A.
    Camarda, G.
    Cui, Y.
    Yang, G.
    James, R. B.
    LISAT: 2009 IEEE LONG ISLAND SYSTEMS, APPLICATIONS AND TECHNOLOGY CONFERENCES, 2009, : 2 - 2
  • [3] Simulation studies of CZT detectors as gamma-ray calorimeter
    Jung, I.
    Krawczynski, H.
    Komarov, S.
    Sobotka, L.
    ASTROPARTICLE PHYSICS, 2006, 26 (02) : 119 - 128
  • [4] Development of CZT Detectors for X-ray and Gamma-ray Astronomy
    Lee, Kuen
    Martin, J. W.
    Garson, A. B., III
    Guo, Q.
    Matteson, J.
    Groza, M.
    Beilicke, M.
    Burger, A.
    de Geronimo, G.
    Krawczynski, H.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIII, 2011, 8142
  • [5] DIIODIDE CRYSTALS FOR GAMMA-RAY DETECTORS
    ZALETIN, VM
    NOZHKINA, IN
    FOMIN, VI
    SHUSTOV, NV
    PROTASOV, II
    SOVIET ATOMIC ENERGY, 1980, 48 (03): : 191 - 194
  • [6] The development of coplanar CZT strip detectors for gamma-ray astronomy
    McConnell, ML
    Hamel, LA
    Macri, JR
    McClish, M
    Ryan, JM
    GAMMA 2001, 2001, 587 : 909 - 913
  • [7] Study of thick CZT detectors for X-ray and Gamma-ray astronomy
    Li, Qiang
    Beilicke, M.
    Lee, Kuen
    Garson, Alfred, III
    Guo, Q.
    Martin, Jerrad
    Yin, Y.
    Dowkontt, P.
    De Geronimo, G.
    Jung, I.
    Krawczynski, H.
    ASTROPARTICLE PHYSICS, 2011, 34 (10) : 769 - 777
  • [8] Characterization of high-resistivity CdTe crystals for gamma-ray detectors
    Shin, HY
    Sun, CY
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1996, 41 (03): : 345 - 351
  • [9] Spectroscopic CZT detectors development for X and Gamma-ray imaging instruments
    Quadrini, Egidio M.
    Uslenghi, Michela
    Alderighi, Monica
    Casini, Fabio
    D'Angelo, Sergio
    Fiorini, Mauro
    La Palombara, Nicola
    Mancini, Marcello
    Monti, Serena
    Bazzano, Angela
    Di Cosimo, Sergio
    Frutti, Massimo
    Natalucci, Lorenzo
    Ubertini, Pietro
    Guadalupi, Giuseppe M.
    Sassi, Matteo
    Negri, Barbara
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XV, 2007, 6686
  • [10] Use of CZT as 3D Detectors for Gamma-Ray Astronomy
    Quadrini, E.
    Alderighi, M.
    Uslenghi, M.
    Auricchio, N.
    Caroli, E.
    Schiavone, F.
    Donati, A.
    Natalucci, L.
    Ubertini, P.
    Del Sordo, S.
    Casini, F.
    Bastia, P.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4973 - +