Reactive extraction of bio-based 3-hydroxypropionic acid assisted by hollow-fiber membrane contactor using TOA and Aliquat 336 in n-decanol

被引:26
|
作者
Burge, Gregoire [1 ,2 ,3 ]
Chemarin, Florian [1 ,2 ,3 ]
Moussa, Marwen [2 ,3 ]
Saulou-Berion, Claire [2 ,3 ]
Allais, Florent [1 ,2 ,3 ]
Spinnler, Henry-Eric [2 ,3 ]
Athes, Violaine [2 ,3 ]
机构
[1] AgroParisTech, Chaire Agrobiotechnol Ind ABI, 247 Rue Paul Vaillant Couturier, F-51100 Reims, France
[2] AgroParisTech, UMR GMPA 782, Batiment CBAI,1 Ave Lucien Bretignieres, F-78850 Thiverval Grignon, France
[3] INRA, UMR GMPA 782, Batiment CBAI,1 Ave Lucien Bretignieres, F-78850 Thiverval Grignon, France
关键词
3-hydroxypropionic acid; reactive extraction; hollow-fiber membrane contactor; trioctylamine; Aliquat; 336; n-decanol; glycerol bioconversion broth; LACTIC-ACID; LACTOBACILLUS-REUTERI; AQUEOUS-SOLUTIONS; CARBOXYLIC-ACIDS; MIXED EXTRACTANT; FERMENTATION; OCTYLAMINE; GLYCEROL; SOLVENT; AMINES;
D O I
10.1002/jctb.4878
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUND: Reactive liquid-liquid extraction is a promising technique for the direct recovery of carboxylic acids from bioconversion media. This work focused on the optimization of 3-hydroxypropionic acid (3-HP) reactive extraction assisted by hollow-fiber membrane contactor (HFMC), using tri-n-octylamine (TOA) and Aliquat 336 as extractants in n-decanol, and on its practical application for the recovery of 3-HP obtained from glycerol bioconversion by Lactobacillus reuteri. RESULTS: The results underlined the influence of the initial pH and 3-HP concentration of the aqueous medium and the impact of extractant phase composition on the extraction performances. The highest distribution coefficient of 3-HP (K-D = 13.0) was observed at pH = 3 with 10% v/v TOA mixed with 10% v/v Aliquat 336 in n-decanol. This study showed that the acid concentration and the ratio of amines used between TOA and Aliquat 336 in n-decanol did not have a great impact on the K-D during 3-HP reactive extraction, whereas it had an influence on the extraction kinetics. Moreover, 3-HP reactive extraction assisted by HFMC from real bioconversion broth with glycerol as the substrate was shown to be feasible, with the same order of magnitude of extraction kinetics but with a lower K-D compared with reactive extraction using model broth. CONCLUSIONS: 3-HP was predominantly extracted from the bioconversion broth, confirming the high selectivity of the extraction process studied and the high potential of this approach applied to the biotechnological production of 3-HP. (C) 2016 Society of Chemical Industry
引用
收藏
页码:2705 / 2712
页数:8
相关论文
共 9 条
  • [1] Towards an in situ product recovery of bio-based 3-hydroxypropionic acid: influence of bioconversion broth components on membrane-assisted reactive extraction
    Chemarin, Florian
    Athes, Violaine
    Bedu, Magali
    Loty, Thomas
    Allais, Florent
    Trelea, Ioan Cristian
    Moussa, Marwen
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2019, 94 (03) : 964 - 972
  • [2] Hollow-fiber membrane extraction of copper(II) from aqueous ethylenediaminetetraacetic acid solutions with Aliquat 336
    Juang, RS
    Huang, IP
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (05) : 1409 - 1415
  • [3] Extraction Kinetics of As(V) by Aliquat-336 Using Asymmetric PVDF Hollow-Fiber Membrane Contactors
    Bey, Said
    Semghouni, Hassina
    Criscuoli, Alessandra
    Benamor, Mohamed
    Drioli, Enrico
    Figoli, Alberto
    MEMBRANES, 2018, 8 (03)
  • [4] Organic phase screening for in-stream reactive extraction of bio-based 3-hydroxypropionic acid: biocompatibility and extraction performances
    Sanchez-Castaneda, Ana Karen
    Moussa, Marwen
    Ngansop, Luther
    Trelea, Ioan Cristian
    Athes, Violaine
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2020, 95 (04) : 1046 - 1056
  • [5] Time-dependent numerical investigation of 3-hydroxypropionic acid extraction using a microporous membrane contactor
    Cao, Yan
    Nakhjiri, Ali Taghvaie
    Sarkar, Shaheen M.
    Ghadiri, Mahdi
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (04):
  • [6] Time-dependent numerical investigation of 3-hydroxypropionic acid extraction using a microporous membrane contactor
    Yan Cao
    Ali Taghvaie Nakhjiri
    Shaheen M. Sarkar
    Mahdi Ghadiri
    The European Physical Journal Plus, 137
  • [7] Reactive liquid-liquid extraction of bio-based 3-hydroxypropionic acid using a biocompatible organic phase containing a tertiary amine: A model-based approach to elucidate dominant mechanisms
    Arana-Agudelo, Pedro
    Moussa, Marwen
    Trelea, Ioan-Cristian
    Lachin, Kevin
    Athes, Violaine
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 294
  • [8] Reactive liquid-liquid extraction of bio-based 3-hydroxypropionic acid using a biocompatible organic phase containing a tertiary amine: A model-based approach to elucidate dominant mechanisms
    Arana-Agudelo, Pedro
    Moussa, Marwen
    Trelea, Ioan-Cristian
    Lachin, Kevin
    Athes, Violaine
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 294
  • [9] Removal of Benzoic Acid from Water by Reactive Extraction Using Hollow Fiber Membrane Contactor: Experiment and Modeling
    Agrahari, Gunjan Kumar
    Verma, Nishith
    Bhattacharya, Prashant K.
    CLEAN-SOIL AIR WATER, 2014, 42 (07) : 901 - 908