High-Precision Isothermal Titration Calorimetry with Automated Peak-Shape Analysis

被引:385
|
作者
Keller, Sandro [2 ]
Vargas, Carolyn [2 ]
Zhao, Huaying [3 ]
Piszczek, Grzegorz [4 ]
Brautigam, Chad A. [1 ]
Schuck, Peter [3 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Biochem, Dallas, TX 75390 USA
[2] Univ Kaiserslautern, D-67663 Kaiserslautern, Germany
[3] Natl Inst Biomed Imaging & Bioengn, Lab Cellular Imaging & Macromol Biophys, NIH, Bethesda, MD 20892 USA
[4] NHLBI, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
BASE-LINE CORRECTION; SOLUBILIZATION; RECONSTITUTION; COOPERATIVITY; CONSTANTS; COMPLEX;
D O I
10.1021/ac3007522
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isothermal titration calorimetry (ITC) is a powerful classical method that enables researchers in many fields to study the thermodynamics of molecular interactions. Primary ITC data comprise the temporal evolution of differential power reporting the heat of reaction during a series of injections of aliquots of a reactant into a sample cell. By integration of each injection peak, an isotherm can be constructed of total changes in enthalpy as a function of changes in solution composition, which is rich in thermodynamic information on the reaction. However, the signals from the injection peaks are superimposed by the stochastically varying time-course of the instrumental baseline power, limiting the precision of ITC isotherms. Here, we describe a method for automated peak assignment based on peak-shape analysis via singular value decomposition in combination with detailed least-squares modeling of local pre- and postinjection baselines. This approach can effectively filter out contributions of short-term noise and adventitious events in the power trace. This method also provides, for the first time, statistical error estimates for the individual isotherm data points. In turn, this results in improved detection limits for high-affinity or low-enthalpy binding reactions and significantly higher precision of the derived thermodynamic parameters.
引用
收藏
页码:5066 / 5073
页数:8
相关论文
共 50 条
  • [1] Titration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data
    Baranauskiene, Lina
    Petrikaite, Vilma
    Matuliene, Jurgita
    Matulis, Daumantas
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2009, 10 (06) : 2752 - 2762
  • [2] High-precision, automated integration of multiple isothermal titration calorimetric thermograms: New features of NITPIC
    Scheuermann, Thomas H.
    Brautigam, Chad A.
    [J]. METHODS, 2015, 76 : 87 - 98
  • [3] Analysis of Cooperativity by Isothermal Titration Calorimetry
    Brown, Alan
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2009, 10 (08) : 3457 - 3477
  • [4] A new automated Isothermal Titration Calorimetry system for increased throughput
    Frasca, V
    Plotnikov, V
    Rochalski, A
    Brandts, M
    Brandts, JM
    Williston, S
    Lin, L
    [J]. PROTEIN SCIENCE, 2004, 13 : 92 - 93
  • [5] A new automated isothermal titration calorimetry system for increased throughput
    Frasca, V
    Plotnikov, V
    Rochalski, A
    Brandts, M
    Brandts, J
    Williston, S
    Lin, LN
    [J]. FASEB JOURNAL, 2004, 18 (08): : C171 - C171
  • [6] Peak-shape analysis using the general Debye equation
    Andreev, YG
    Bruce, PG
    [J]. EPDIC 7: EUROPEAN POWDER DIFFRACTION, PTS 1 AND 2, 2001, 378-3 : 148 - 153
  • [7] Composite scintillators for high-precision calorimetry
    Bumazhnov, VA
    Durum, AA
    Kochetkov, VI
    Mayatskii, VA
    Onuchin, VA
    Semenov, VK
    Soldatov, AP
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1999, 42 (04) : 505 - 510
  • [9] HIGH-PRECISION COULOMETRIC TITRATION OF URANIUM
    MARINENKO, G
    KOCH, WF
    ETZ, ES
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1983, 88 (02): : 117 - 124
  • [10] PEAK-SHAPE ANALYSIS FOR UNRESOLVED PEAKS IN CHROMATOGRAPHY - COMPARISON OF ALGORITHMS
    REH, E