24-Hour Performance of Albumin Dialysis Assessed by a New Two-Compartment In Vitro Model

被引:4
|
作者
Stiffel, Melanie [1 ]
Dammeier, Nele [1 ]
Schmidt, Stephanie [1 ]
Szyszkowitz, Tina [1 ]
Sikole, Magdalena [1 ]
Sieveking, Catharina [1 ]
Stange, Jan [1 ]
机构
[1] Univ Rostock, Fac Med, Div Nephrol, Dept Med, D-18055 Rostock, Germany
关键词
Albumin binding capacity; Molecular Adsorbent Recirculating System; Caprylate; Clearance; Liver Support; N-Acetyltryptophan; Stabilizers; FRACTIONATED PLASMA SEPARATION; SORBENT SUSPENSION; LIVER SUPPORT; SYSTEM; CIRRHOSIS; DIALYZER; REMOVAL; FAILURE;
D O I
10.1111/1744-9987.12025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Extracorporeal albumin dialysis as a measure to remove water soluble and protein bound toxins simultaneously has been shown to improve complications of liver failure. However, recent research suggests that only treatments associated with a measurable improvement of patient's albumin binding function by effective removal of albumin bound toxins leads to better survival. The aim of the present work was to develop a test platform for upcoming devices to evaluate long term effectiveness on toxin removal and improvement of patients' albumin binding capacity. The classical one compartment model consisting of a closed pool of toxin spiked plasma was combined with continuous infusion of water soluble and protein bound toxins mimicking physiological rebound rates reflected in the literature. The model was used to demonstrate the effect of stabilizer contamination of dialysate albumin on toxin clearance and albumin binding function. In comparison to the classical one compartment model, the two compartment model allows for long term effectiveness tests of liver assist devices not only for strongly albumin-bound, but also water-soluble molecules. The limitations of commercial albumin overloaded with caprylate ligands (5:1 molar ratio) were demonstrated by presenting a significant improvement of albumin binding function using 80g deligandized albumin compared to no significant improvement using the standard 120g albumin as dialysate. The new two compartment model allows for pre-clinical evaluation of new upcoming devices aiming for improvement of patients' albumin binding function as a measure for clinically meaningful extracorporeal detoxification of albumin-bound toxins.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 25 条
  • [1] A two-compartment in vitro model for studies of modulation of nociceptive transmission
    Vikman, KS
    Backström, E
    Kristensson, K
    Hill, RH
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2001, 105 (02) : 175 - 184
  • [2] Post-dialysis urea concentration: comparison between one-compartment model and two-compartment model
    Tamrin, N. S. Ahmad
    Ibrahim, N.
    [J]. 9TH NATIONAL SEMINAR ON MEDICAL PHYSICS (NSMP2014), 2014, 546
  • [3] Estimation of sodium and potassium intakes assessed by two 24-hour urine collections in a city of Indonesia
    Sari, Dianis Wulan
    Noguchi-Watanabe, Maiko
    Sasaki, Satoshi
    Sahar, Junaiti
    Yamamoto-Mitani, Noriko
    [J]. BRITISH JOURNAL OF NUTRITION, 2021, 126 (10) : 1537 - 1548
  • [4] A NEW TWO-COMPARTMENT MODEL OF PATIENT-ARTIFICIAL KIDNEY SYSTEM INCLUDING CSF COMPARTMENT
    张凤宝
    张国亮
    王绍亭
    姜埃利
    刘建勇
    马腾骧
    [J]. Chinese Journal of Chemical Engineering, 1994, (04) : 44 - 52
  • [5] Preoperative assessment of hepatic function: Utility of a new convenient two-compartment model analysis using galactosyl human serum albumin scintigraphy
    Kinoshita, K
    Ukikusa, M
    Iwaisako, K
    Arimoto, A
    Fujisawa, N
    Ozaki, T
    Tanaka, H
    Seo, S
    Naitoh, M
    Nomura, A
    Inomoto, T
    Kitai, T
    Ino, K
    Higashiyama, H
    Hanafusa, T
    Nakajima, Y
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2003, 18 (01) : 99 - 104
  • [6] A New Method for the Estimation of Absorption Rate Constant in Two-Compartment Model by Extravascular Administration
    Zeng, Ye
    Liu, Jianxiong
    Liu, Wenjie
    Jiang, Shan
    Wang, Shanshan
    Cheng, Zeneng
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 109 (05) : 1802 - 1810
  • [7] PREVALENCE OF APPARENT-TREATMENT RESISTANT HYPERTENSION IN PERITONEAL DIALYSIS PATIENTS ASSESSED WITH THE USE OF 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
    Vareta, Georgia
    Georgianos, Panagiotis
    Vaios, Vasilios
    Sgouropoulou, Vasiliki
    Roumeliotis, Stefanos
    Georgoulidou, Anastasia
    Dounousi, Evangelia
    Eleftheriadis, Theodo-Ros
    Papagianni, Aikaterini
    Balaskas, Elias
    Zebekakis, Pantelis
    Liakopoulos, Vassilios
    [J]. JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E289 - E290
  • [8] THREE-PORE MODEL PREDICTIONS OF 24-HOUR AUTOMATED PERITONEAL DIALYSIS THERAPY USING BIMODAL SOLUTIONS
    Akonur, Alp
    Leypoldt, J. Ken
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2011, 31 (05): : 537 - 544
  • [9] Minimal model overestimation of SG and underestimation of SI corrected by Bayesian identification of a new two-compartment minimal model
    Caumo, A
    Cobelli, C
    [J]. DIABETES, 1998, 47 : A285 - A285
  • [10] NEW ALGORITHM FOR QT INTERVAL-ANALYSIS IN 24-HOUR HOLTER ECG - PERFORMANCE AND APPLICATIONS
    LAGUNA, P
    THAKOR, NV
    CAMINAL, P
    JANE, R
    YOON, HR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) : 67 - 73