Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography

被引:30
|
作者
Goedhart, AD [1 ]
Kupper, N [1 ]
Willemsen, G [1 ]
Boomsma, DI [1 ]
de Geus, EJC [1 ]
机构
[1] Free Univ Amsterdam, Dept Biol Psychol, NL-1081 BT Amsterdam, Netherlands
关键词
sympathetic nervous system; temporal stability; hemodynamic regulation; impedance cardiography;
D O I
10.1016/j.biopsycho.2005.08.004
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascular disease. In this study, 24 It ambulatory impedance-derived systolic time intervals, stroke volume and cardiac output were measured in 65 healthy subjects across an average time span of 3 years and 4 months. Stability was computed separately for sleep and daytime recordings. To avoid confounding by differences in posture and physical activity across measurement days, temporal stability was computed using sitting activities only. During the day intraclass correlations were moderate for stroke volume (.29-.46) and cardiac output (.33-.46) and good for systolic time intervals (.55-.81). When test-retest comparison was limited to two comparable days (two work days or two leisure days), correlations for both SV (.42-.46) and CO (.43-.50) improved. Conclusion: Moderate long-term temporal stability is found for individual differences in ambulatory stroke volume and cardiac output measured by impedance cardiography. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 50 条
  • [1] THE STROKE VOLUME AND THE CARDIAC OUTPUT BY THE IMPEDANCE CARDIOGRAPHY
    Ipate, M. C.
    Dobre, A. A.
    Morega, A. M.
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2012, 74 (03): : 219 - 232
  • [2] Validation of the ambulatory measurement of stroke volume by impedance cardiography
    Riese, H
    DeGeus, E
    VanDoornen, L
    PSYCHOPHYSIOLOGY, 1996, 33 : S70 - S70
  • [3] The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: A review
    Newman, DG
    Callister, R
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1999, 70 (08): : 780 - 789
  • [4] CARDIAC OUTPUT MEASURED BY NONINVASIVE IMPEDANCE CARDIOGRAPHY AND PICU OUTCOMES
    Sumbel, Lydia
    Wats, Anchal
    Bhalala, Utpal
    CRITICAL CARE MEDICINE, 2020, 48
  • [5] CARDIAC-OUTPUT IN NORMAL-PREGNANCY MEASURED BY IMPEDANCE CARDIOGRAPHY
    MYHRMAN, P
    GRANERUS, G
    KARLSSON, K
    LUNDGREN, Y
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1982, 42 (06): : 513 - 520
  • [6] CARDIOVASCULAR CHANGES DURING LAPAROSCOPY - STUDIES OF STROKE VOLUME AND CARDIAC-OUTPUT USING IMPEDANCE CARDIOGRAPHY
    LENZ, RJ
    THOMAS, TA
    WILKINS, DG
    ANAESTHESIA, 1976, 31 (01) : 4 - 12
  • [7] Stroke volume equation for impedance cardiography
    Bernstein, DP
    Lemmens, HJM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (04) : 443 - 450
  • [8] MEASUREMENT OF STROKE VOLUME WITH IMPEDANCE CARDIOGRAPHY
    MILSOM, I
    SIVERTSSON, R
    BIBER, B
    OLSSON, T
    CLINICAL PHYSIOLOGY, 1982, 2 (05): : 409 - 417
  • [9] Stroke volume equation for impedance cardiography
    D. P. Bernstein
    H. J. M. Lemmens
    Medical and Biological Engineering and Computing, 2005, 43 : 443 - 450
  • [10] STROKE VOLUME AND CARDIAC OUTPUT MEASURED BY ECHOCARDIOGRAPHY
    PENNOCK, R
    KINGSLEY, B
    KAWAI, N
    KIMBIRIS, D
    SEGAL, BL
    AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (01): : 121 - &