Passive-fixation lead failure rates and long-term patient mortality in subjects implanted with Sprint Fidelis electrodes

被引:11
|
作者
Vollmann, Dirk [1 ]
Woronowicz, Sandra [1 ,2 ]
Kmiec, Lukasz [1 ,2 ]
Jung, Klaus [3 ]
Zenker, Dieter [4 ]
Seegers, Joachim [1 ]
Sossalla, Samuel [1 ]
Dorenkamp, Marc [1 ,5 ]
Sohns, Christian [1 ]
Luethje, Lars [1 ]
Hasenfuss, Gerd [1 ]
Zabel, Markus [1 ]
机构
[1] Univ Gottingen, Univ Med Ctr Gottingen, Dept Cardiol & Pneumol, Div Clin Electrophysiol, D-37075 Gottingen, Germany
[2] Univ Leipzig, Ctr Heart, Dept Cardiac Surg, D-04289 Leipzig, Germany
[3] Univ Gottingen, Univ Med Ctr Gottingen, Dept Med Stat, D-37075 Gottingen, Germany
[4] Univ Med Ctr Gottingen, Dept Thorac & Cardiovasc Surg, D-37075 Gottingen, Germany
[5] Charite, Dept Cardiol, D-13353 Berlin, Germany
来源
EUROPACE | 2014年 / 16卷 / 02期
关键词
Lead failure; Passive fixation; ICD; Mortality; INAPPROPRIATE SHOCKS; INTEGRITY; PERFORMANCE; FRACTURES; THERAPY; IMPACT; RISK;
D O I
10.1093/europace/eut185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate passive-fixation lead failure rates and long-term patient survival in subjects implanted with Sprint Fidelis electrodes. We identified 748 subjects who received a Sprint Fidelis (n 429; Medtronic models 6948: 94.8, 6949: 2.6, 6930: 1.9, 6931: 0.7) or a Sprint non-Fidelis implantable cardioverter defibrillator lead (n 319, Medtronic models 6944: 68.6, 6947: 17.9, 6942: 7.8, 6943: 3.4, 6945: 2.2) at our centre between 1998 and 2008. KaplanMeier patient survival was lower in the Fidelis group than in the Control cohort (68.4 vs. 77.0 at 5 years, P 0.0061), but multivariate analyses revealed no significant association between mortality and implanted lead type. Passive-fixation lead failure rate at 5 years was 14.4 (95 confidence interval (CI) [9.2, 19.3]) in the Fidelis (n 414) group and 1.8 (95 CI [0.03.8]) in the Control (n 241) cohort (P 0.001 upon multivariate comparison). Failure rates of passive-fixation Sprint Fidelis leads are increased and similar to those previously reported for active-fixation Fidelis electrodes. Despite the elevated risk for lead failure and its potential sequelae, the Sprint Fidelis has no obvious impact on long-term mortality.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 30 条
  • [1] Impact of Implanted Recalled Sprint Fidelis Lead on Patient Mortality
    Morrison, Thomas B.
    Friedman, Paul A.
    Kallinen, Linda M.
    Hodge, David O.
    Crusan, Daniel
    Kumar, Kapil
    Hayes, David L.
    Rea, Robert F.
    Hauser, Robert G.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (03) : 278 - 283
  • [2] Long-term performance of the Medtronic Sprint Fidelis lead: a matter of lead type?
    Frey, Simon Martin
    Sticherling, Christian
    Bucher, Urs
    Widmer, Regula
    Ammann, Peter
    Kuehne, Mischa
    Osswald, Stefan
    Schaer, Beat
    [J]. EUROPACE, 2012, 14 (11): : 1620 - 1623
  • [3] Pacemaker and Implantable Defibrillator Lead Survival and Malfunction Study: Long-term Follow-up of the Sprint Fidelis Lead
    Cohen, Todd J.
    Maltempi, Wendy
    Doorty, Gerard
    Feuerman, Martin
    [J]. CIRCULATION, 2010, 122 (21)
  • [4] Hospitalized heart failure: Rates and long-term mortality
    Shahar, E
    Lee, S
    Kim, J
    Duval, S
    Barber, C
    Luepker, RV
    [J]. JOURNAL OF CARDIAC FAILURE, 2004, 10 (05) : 374 - 379
  • [5] Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads
    Yeh, KH
    Wang, CC
    Wen, MS
    Chou, CC
    Yeh, SJ
    Wu, DL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1399 - 1404
  • [6] A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
    Liu, Lie
    Tang, Jiaojiao
    Peng, Hu
    Wu, Shulin
    Lin, Chunying
    Chen, Dongli
    Zhang, Qianhuan
    Liang, Yuanhong
    Chen, Silin
    Chen, Yan
    Wei, Huiqiang
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [7] A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
    Lie Liu
    Jiaojiao Tang
    Hu Peng
    Shulin Wu
    Chunying Lin
    Dongli Chen
    Qianhuan Zhang
    Yuanhong Liang
    Silin Chen
    Yan Chen
    Huiqiang Wei
    [J]. Scientific Reports, 5
  • [8] Microscopic Characterization of Failure Mechanisms in Long-Term Implanted Microwire Neural Electrodes
    Zhang, Z. J.
    Li, Q.
    Dong, Z. Y.
    Wang, W. T.
    Lai, S. T.
    Yang, X.
    Liang, F.
    Wang, C. L.
    Luo, C.
    Lyu, J.
    Li, Z.
    Xu, J. M.
    Wu, X.
    [J]. 2023 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM, IRPS, 2023,
  • [9] Frailty predicts long-term mortality in elderly subjects with chronic heart failure
    Cacciatore, F
    Abete, P
    Mazzella, F
    Viati, L
    Della Morte, D
    D'Ambrosio, D
    Gargiulo, G
    Testa, G
    De Santis, D
    Galizia, G
    Ferrara, N
    Rengo, F
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2005, 35 (12) : 723 - 730
  • [10] Depression predicts long-term mortality in elderly subjects with chronic heart failure
    Testa, G.
    Cacciatore, F.
    Mazzella, F.
    Galizia, G.
    Della-Morte, D.
    Langellotto, A.
    Avolio, D.
    Gargiulo, G.
    Rengo, F.
    Abete, P.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 564 - 564