Enantioselective sensing of chiral amino acids by potentiometric sensors based on optical active polyaniline films

被引:57
|
作者
Yin, XL [1 ]
Ding, JJ [1 ]
Zhang, S [1 ]
Kong, JL [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2006年 / 21卷 / 11期
基金
中国国家自然科学基金;
关键词
optical active polyaniline; potentiometric sensor; enantioselective analysis; amino acid;
D O I
10.1016/j.bios.2005.10.010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel enantioselective potentiometric sensor was constructed based on optical active polyaniline (PAn) films. The sensor with high stability showed discrimination behavior toward one isomer of racemic phenylalanine (Phe). The (-) or (+) PAn-based electrodes exhibited an excellent Nernstian slope of similar to 60 mV per decade for L-Phe or D-Phe, respectively. In addition, when the sensor was exposed to the mixture of enantiomers, the slope of the response changed along with their proportions, which would be employed as an index of the enantiomeric purity of the mixture. At last, the mechanism of chiral discrimination for Phe was discussed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2184 / 2187
页数:4
相关论文
共 50 条
  • [1] Potentiometric sensing of chiral amino acids
    Zhou, YX
    Yu, B
    Levon, K
    CHEMISTRY OF MATERIALS, 2003, 15 (14) : 2774 - 2779
  • [2] Chiral Ru-Based Covalent Organic Frameworks as An Electrochemiluminescence-Active Platform for the Enantioselective Sensing of Amino Acids
    Yuan, Shuyi
    Tan, Lilan
    Zhao, Lei
    Wang, Fangqin
    Cai, Wenrong
    Li, Junyao
    Wu, Datong
    Kong, Yong
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (10) : 13161 - 13169
  • [3] Chiral Ru-Based Covalent Organic Frameworks as An Electrochemiluminescence-Active Platform for the Enantioselective Sensing of Amino Acids
    Yuan S.
    Tan L.
    Zhao L.
    Wang F.
    Cai W.
    Li J.
    Wu D.
    Kong Y.
    ACS Applied Materials and Interfaces, 2024, 16 (10): : 13161 - 13169
  • [4] Chiral Polyaniline Hollow Nanotwists toward Efficient Enantioselective Separation of Amino Acids
    Zhou, Chuanqiang
    Ren, Yuanyuan
    Han, Jie
    Xu, Qianqian
    Guo, Rong
    ACS NANO, 2019, 13 (03) : 3534 - 3544
  • [5] Enantioselective sensing of chiral carboxylic acids
    Mei, XF
    Wolf, C
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (45) : 14736 - 14737
  • [6] Enantioselective recognition by optically active chiral fluorescence sensors bearing amino acid units
    Xu, KX
    He, YB
    Qin, HJ
    Qing, GY
    Liu, SY
    TETRAHEDRON-ASYMMETRY, 2005, 16 (18) : 3042 - 3048
  • [7] Enantioselective fluorescence sensing of chiral α-amino alcohols
    Liu, Shuanglong
    Pestano, John Paul C.
    Wolf, Christian
    JOURNAL OF ORGANIC CHEMISTRY, 2008, 73 (11): : 4267 - 4270
  • [8] Enantioselectivity of amino acids using chiral sensors based on nanotubes
    Vardanega, D.
    Picaud, F.
    Girardet, C.
    JOURNAL OF CHEMICAL PHYSICS, 2009, 130 (11):
  • [9] Enantioselective recognition of amino acids based on molecularly imprinted polyaniline electrode column
    Kong, Yong
    Ni, Junhua
    Wang, Wenchang
    Chen, Zhidong
    ELECTROCHIMICA ACTA, 2011, 56 (11) : 4070 - 4074
  • [10] Influence of thickness on optical parameters' and structures of a polyaniline films for active elements of optical fiber sensors
    Hotra, Z. Yu.
    Cherpak, V. V.
    Hlushyk, I. P.
    Stakhira, P. Y.
    Volynyuk, D. M.
    LIGHTGUIDES AND THEIR APPLICATIONS III, 2007, 6608