High performance liquid chromatography of disaccharides on a porous graphitic carbon column applying post-column derivatization with benzamidine

被引:23
|
作者
Koimur, M [1 ]
Lu, B [1 ]
Westerlund, D [1 ]
机构
[1] UNIV UPPSALA,CTR BIOMED,FAC PHARM,S-75123 UPPSALA,SWEDEN
关键词
column liquid chromatography; carbohydrates; anomer separations; post-column derivatization;
D O I
10.1007/BF02270990
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive post-column fluorescence method based on the reaction of reducing sugars with a fluorigenic reagent (benzamidine) under alkaline conditions and elevated temperature is described. Optimum reaction conditions suitable for the detection of fluorescent reaction products have been investigated. A porous graphitized carbon column (Shandon Hypercarb) was employed as the chromatographic solid phase and elution was isocratic by an aqueous acetonitrile mixture. A special problem in sugar analysis is the tendency of anomer formation giving doublet peaks. This tendency varies largely among the different sugars, and systematic studies on conditions that eliminate this problem were performed. Efficient and selective separations of a series of disaccharides were obtained using high temperatures and a low concentration of acetonitrile in the mobile phase. The detection limits (S/N = 3) with an injection volume of 20 mu L ranged from 10-60 picomoles. Linear calibration graphs were obtained in the 2-20 mu M concentration range (r(2) > 0.99). A relative standard deviation between 1-3 % (n = 6) demonstrated good precision of the developed system.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [1] Determination of artemisinin by post-column derivatization high performance liquid chromatography
    Li, Ming
    Wu, Xianxue
    Yang, Yan
    Lin, Hong
    Chai, Yuedong
    Ai, Hua Lin
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (03) : 1907 - 1914
  • [2] Post-column photochemical derivatization in high-performance liquid chromatography
    Lores, M
    Cabaleiro, O
    Cela, R
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (06) : 392 - 400
  • [3] LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION
    FREI, RW
    BRINKMAN, UAT
    [J]. ACTA PHARMACEUTICA SUECICA, 1982, 19 (01): : 65 - 65
  • [4] NEW ASPECTS OF POST-COLUMN DERIVATIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FREI, RW
    MICHEL, L
    SANTI, W
    [J]. JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV): : 261 - 270
  • [5] POST-COLUMN DERIVATIZATION OF SUGARS BY LIQUID-CHROMATOGRAPHY
    NUOR, SK
    VIALLE, J
    ROCCA, JL
    [J]. ANALUSIS, 1979, 7 (7-8) : 381 - 385
  • [6] DETERMINATION OF ALKANOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION
    NAKAE, A
    MANSHO, K
    TSUJI, K
    [J]. BUNSEKI KAGAKU, 1981, 30 (06) : 353 - 357
  • [7] AN UPDATE ON POST-COLUMN DERIVATIZATION METHODOLOGY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STEWART, JT
    BACHMAN, WJ
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1988, 7 (03) : 106 - 111
  • [8] Determination of Narasin in Chicken Tissues by High Performance Liquid Chromatography with Post-column Derivatization
    Wu Yin-Liang
    Wang Li-Jun
    Yang Ting
    Zhao Jian
    Huangfu Wei-Guo
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1069 - 1072
  • [9] High performance liquid chromatography of a cyclosporin A formulation on a porous graphitic carbon column
    Nazir, T
    Gould, LA
    Marriott, C
    Martin, GP
    Brown, MB
    [J]. CHROMATOGRAPHIA, 1997, 46 (11-12) : 628 - 636
  • [10] High performance liquid chromatography of a cyclosporin A formulation on a porous graphitic carbon column
    T. Nazir
    L. A. Gould
    C. Marriott
    G. P. Martin
    M. B. Brown
    [J]. Chromatographia, 1997, 46 : 628 - 636