Measurement of exchange anisotropy in exchange-bias bilayers

被引:12
|
作者
Hu, JG [1 ]
Jin, GJ
Stamps, RL
Ma, YQ
机构
[1] Nanjing Univ, Natl Lab Solid State Microstruct, Nanjing 210093, Peoples R China
[2] Yangzhou Univ, Coll Phys Sci & Technol, Yangzhou 225002, Peoples R China
[3] Univ Western Australia, Sch Phys, Nedlands, WA 6009, Australia
关键词
FM/AFM bilayers; exchange anisotropy; bilinear and biquadratic couplings;
D O I
10.1016/j.jmmm.2005.06.028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recently, experimental results for ferromagnetic (FM) and anti ferromagnetic (AFM) bilayers show that the measured exchange anisotropy depends on what measurement is done. In this article, we theoretically investigate how the interface exchange coupling including bilinear and biquadratic terms manifests itself in different measurements such as hysteresis loop, ac susceptibility, and ferromagnetic resonance in FM/AFM bilayers. In the semi-infinite limit for the AFM layer, the analytical expressions for measured exchange anisotropy from the hysteresis loop, ac susceptibility and ferromagnetic resonance are derived. It is found that the intrinsic magnetic parameters, such as FM anisotropy constant, AFM domain wall energy, and the interface exchange coupling including the bilinear and biquadratic contributions, can play different roles in different measurement techniques. However, by comparing different measurements the intrinsic magnetic parameters, the domain energy sigma(AFM) and the bilinear and biquadratic exchange coupling constants J(E1) and J(E2), can be determined, respectively. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] Rotatable anisotropy and coercivity in exchange-bias bilayers
    Geshev, J
    Pereira, LG
    Schmidt, JE
    [J]. PHYSICAL REVIEW B, 2002, 66 (13) : 1 - 8
  • [2] Coercivity in exchange-bias bilayers
    Stiles, MD
    McMichael, RD
    [J]. PHYSICAL REVIEW B, 2001, 63 (06)
  • [3] On the controversial measurements of the exchange-bias field in magnetic bilayers
    Rodríguez-Suárez, RL
    Leao, LHV
    Agular, FM
    Rezende, SM
    Azevedo, A
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 272 : 1212 - 1214
  • [4] Enhanced coercivity of exchange-bias Fe/MnPd bilayers
    Tang, YJ
    Roos, B
    Mewes, T
    Demokritov, SO
    Hillebrands, B
    Wang, YJ
    [J]. APPLIED PHYSICS LETTERS, 1999, 75 (05) : 707 - 709
  • [5] Mechanism of the exchange-bias field in ferromagnetic and antiferromagnetic bilayers
    Mitsumata, C
    Sakuma, A
    Fukamichi, K
    [J]. PHYSICAL REVIEW B, 2003, 68 (01)
  • [6] Size and shape dependence of the exchange-bias field in exchange-coupled ferrimagnetic bilayers
    M. Ziese
    R. Höhne
    A. Bollero
    H.-C. Semmelhack
    P. Esquinazi
    K. Zimmer
    [J]. The European Physical Journal B - Condensed Matter and Complex Systems, 2005, 45 : 223 - 230
  • [7] Size and shape dependence of the exchange-bias field in exchange-coupled ferrimagnetic bilayers
    Ziese, M
    Höhne, R
    Bollero, A
    Semmelhack, HC
    Esquinazi, P
    Zimmer, K
    [J]. EUROPEAN PHYSICAL JOURNAL B, 2005, 45 (02): : 223 - 230
  • [8] Exchange bias for ferromagnetic/antiferromagnetic bilayers with the uniaxial anisotropy being misaligned with the exchange anisotropy
    Bai YuHao
    Yun GuoHong
    [J]. SCIENCE IN CHINA SERIES G-PHYSICS MECHANICS & ASTRONOMY, 2009, 52 (12): : 1885 - 1892
  • [9] Exchange bias for ferromagnetic/antiferromagnetic bilayers with the uniaxial anisotropy being misaligned with the exchange anisotropy
    BAI YuHao1 & YUN GuoHong1
    2 Key Laboratory of Physics and Chemistry of Functional Materials
    [J]. Science China(Physics,Mechanics & Astronomy), 2009, (12) : 1885 - 1892
  • [10] Exchange bias for ferromagnetic/antiferromagnetic bilayers with the uniaxial anisotropy being misaligned with the exchange anisotropy
    YuHao Bai
    GuoHong Yun
    [J]. Science in China Series G: Physics, Mechanics and Astronomy, 2009, 52 : 1885 - 1892