Multiplexed end-point microfluidic chemotaxis assay using centrifugal alignment

被引:5
|
作者
Satti, Sampath [1 ,2 ]
Deng, Pan [2 ,3 ]
Matthews, Kerryn [2 ,3 ]
Duffy, Simon P. [2 ,3 ,4 ]
Ma, Hongshen [1 ,2 ,3 ,5 ]
机构
[1] Univ British Columbia, Sch Biomed Engn, Vancouver, BC, Canada
[2] Univ British Columbia, Ctr Blood Res, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Mech Engn, Vancouver, BC, Canada
[4] British Columbia Inst Technol, Vancouver, BC, Canada
[5] Univ British Columbia, Dept Urol Sci, Vancouver, BC, Canada
基金
瑞典研究理事会; 加拿大自然科学与工程研究理事会;
关键词
NEUTROPHIL CHEMOTAXIS; MIGRATION;
D O I
10.1039/d0lc00311e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fundamental challenge to multiplexing microfluidic chemotaxis assays at scale is the requirement for time-lapse imaging to continuously track migrating cells. Drug testing and drug screening applications require the ability to perform hundreds of experiments in parallel, which is not feasible for assays that require continuous imaging. To address this limitation, end-point chemotaxis assays have been developed using fluid flow to align cells in traps or sieves prior to cell migration. However, these methods require precisely controlled fluid flow to transport cells to the correct location without undesirable mechanical stress, which introduce significant set up time and design complexity. Here, we describe a microfluidic device that eliminates the need for precise flow control by using centrifugation to align cells at a common starting point. A chemoattractant gradient is then formed using passive diffusion prior to chemotaxis in an incubated environment. This approach provides a simple and scalable approach to multiplexed chemotaxis assays. Centrifugal alignment is also insensitive to cell geometry, enabling this approach to be compatible with primary cell samples that are often heterogeneous. We demonstrate the capability of this approach by assessing chemotaxis of primary neutrophils in response to an fMLP (N-formyl-met-leu-phe) gradient. Our results show that cell alignment by centrifugation offers a potential avenue to develop scalable end-point multiplexed microfluidic chemotaxis assays.
引用
收藏
页码:3096 / 3103
页数:8
相关论文
共 50 条
  • [1] A SPECIFIC END-POINT ASSAY FOR UBIQUITIN
    ROSE, IA
    WARMS, JVB
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1987, 84 (06) : 1477 - 1481
  • [2] ACCURACY OF THE END-POINT ASSAY FOR VIRUS TITRATION
    NIELSEN, LK
    SMYTH, GK
    GREENFIELD, PF
    CYTOTECHNOLOGY, 1992, 8 (03) : 231 - 236
  • [3] QUANTITATION OF SERUM-PROTEINS BY CENTRIFUGAL END-POINT TURBIDIMETRY
    HORSFALL, KM
    PETERSEN, JG
    TISEL, WA
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1145 - 1145
  • [4] A simple end-point assay method for Calcium channels
    Steephan, M.
    Rajeevkumar, R.
    Arunkumar, R. C.
    Priya, S. Suma
    Paul, S.
    Archana, G. M.
    Mayadevi, M.
    Omkumar, R. V.
    JOURNAL OF NEUROCHEMISTRY, 2013, 125 : 250 - 251
  • [5] A simple end-point assay for calcium channel activity
    Chandrika, Arunkumar Renganathan
    Steephan, Mathew
    Nair, Rajeevkumar Raveendran
    Devi, Suma Priya Sudarsana
    Kumar, Mantosh
    Paul, Soumya
    Madhavan, Mayadevi
    Omkumar, Ramakrishnapillai, V
    CELL CALCIUM, 2018, 74 : 73 - 85
  • [6] A RADIOCHEMICAL ENZYMATIC END-POINT ASSAY FOR GTP AND GDP
    CERPOVICZ, PF
    OCHS, RS
    ANALYTICAL BIOCHEMISTRY, 1991, 192 (01) : 197 - 202
  • [7] THE IMMATURE RAT UTERUS AS AN ASSAY END-POINT FOR GONADOTROPIC SUBSTANCES
    Heller, Carl G.
    Lauson, Henry
    Sevringhaus, Elmer L.
    AMERICAN JOURNAL OF PHYSIOLOGY, 1938, 121 (02): : 364 - 378
  • [8] A Sensitive Chemotaxis Assay Using a Novel Microfluidic Device
    Zhang, Chen
    Jang, Sunyoung
    Amadi, Ovid C.
    Shimizu, Koichi
    Lee, Richard T.
    Mitchell, Richard N.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [9] IMPROVED ENZYMATIC ASSAY FOR SERUM FORMATE WITH COLORIMETRIC END-POINT
    GRADY, S
    OSTERLOH, J
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1986, 10 (01) : 1 - 5
  • [10] THE APPLICATION OF SULFORHODAMINE-B AS A COLORIMETRIC END-POINT IN A CYTOTOXICITY ASSAY
    FRICKER, SP
    TOXICOLOGY IN VITRO, 1994, 8 (04) : 821 - 822