On using Rayleigh scattering for in situ spectral calibration of Thomson scattering diagnostics

被引:3
|
作者
Bozhenkov, S. A. [1 ]
Heym, S. J. [2 ]
Beurskens, M. N. A. [1 ]
Fuchert, G. [1 ]
Pasch, E. [1 ]
Scott, E. R. [1 ]
Wolf, R. C. [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
[2] Tech Univ Berlin, Fac Math & Nat Sci, Hardenbergstr 36, D-10623 Berlin, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 03期
关键词
DISPERSION;
D O I
10.1063/1.5072781
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method for in situ spectral calibration of Thomson scattering diagnostics is proposed. The idea of the method is to apply a wavelength tunable optical parametric oscillator for measurements of Rayleigh scattering at different wavelengths, from which relative sensitivities can be calculated. This extends the usual approach where Rayleigh scattering is used only at a single wavelength for the absolute calibration and spectral sensitivities are obtained separately. With the new approach, the full diagnostic setup is spectrally calibrated at once. Such a calibration can be repeated at regular intervals during an experimental campaign since it does not require a break of the vacuum. In this paper, the Rayleigh scattering calibration is tested in a laboratory setup with a sample Wendelstein 7-X (W7-X) polychromator. It is shown that relative sensitivities of spectral channels can be recovered with a sufficient resolution even under conditions of significant stray light. The stray light is overcome by measuring the linear dependence of the scattered signal on the gas pressure. Good results of laboratory tests motivate the installation of the new calibration system for the Thomson scattering diagnostic at W7-X. Published under license by AIP Publishing.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Demonstration of an absolute Rayleigh scattering spectral calibration on the W7-X Thomson scattering system
    Scott, E. R.
    Beurskens, M. N. A.
    Bozhenkov, S. A.
    Fuchert, A. G.
    Hirsch, M.
    Nelde, P.
    Pasch, E.
    Wolf, R. C.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [2] Thomson scattering density calibration by Rayleigh and rotational Raman scattering on NSTX
    LeBlanc, B. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [3] Scattering diagnostics of low-temperature plasmas (Rayleigh scattering, Thomson scattering, CARS)
    Kempkens, H
    Uhlenbusch, J
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2000, 9 (04): : 492 - 506
  • [4] An In Situ Spectral Calibration Method for the Thomson Scattering Diagnostic for New Fusion Experiments
    Tojo, Hiroshi
    Hatae, Takaki
    Itami, Kiyoshi
    FUSION SCIENCE AND TECHNOLOGY, 2016, 69 (02) : 546 - 554
  • [5] A novel polychromator calibration method for Thomson scattering diagnostics
    Xie, Q. F.
    Li, H. Y.
    Tao, R. Y.
    Li, N.
    Li, S. J.
    Liu, J. H.
    Lun, X. C.
    Bai, R. H.
    Deng, B. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (07):
  • [6] Principle of an in-situ relative calibration method using a double-pass beam for Thomson scattering diagnostics
    Tojo, H.
    Hatae, T.
    Itami, K.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [7] Calibration techniques for Thomson scattering diagnostics on large fusion experiments
    Fuchert, G.
    Wagner, J.
    Henschke, L. V.
    Pasch, E.
    Beurskens, M. N. A.
    Bozhenkov, S. A.
    Brunner, K. J.
    Chen, S.
    Frank, J. M.
    Hirsch, M.
    Knauer, J.
    Wolf, R. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (08):
  • [8] INSITU DYE-LASER CALIBRATION FOR THOMSON SCATTERING DIAGNOSTICS
    RASMUSSEN, DA
    KINDSFATHER, RR
    THOMAS, CE
    GORMLEY, RP
    PAINTER, SL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1464 - 1466
  • [9] LIMITS OF PLASMA DIAGNOSTICS USING THOMSON SCATTERING
    PYATNITSKII, LN
    HIGH TEMPERATURE, 1975, 13 (06) : 1188 - 1190
  • [10] GRAPHS FOR THOMSON SCATTERING DIAGNOSTICS
    LEONARD, T
    OPTICAL SPECTRA, 1977, 11 (08): : 84 - 87