Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease

被引:10
|
作者
Oh, Jin-Kyoung [1 ]
Choi, Eun-Kyoung [1 ]
Song, In-Uk [2 ]
Kim, Joong-Seok [2 ]
Chung, Yong-An [1 ]
机构
[1] Catholic Univ Korea, Dept Radiol, Coll Med, Incheon St Marys Hosp, Inchon 403720, South Korea
[2] Catholic Univ Korea, Dept Neurol, Coll Med, Seoul 137701, South Korea
关键词
I-123; MIBG; Planar scintigraphy; SPECT; Parkinson's disease; Sensitivity and specificity; CARDIAC SYMPATHETIC DENERVATION; METAIODOBENZYLGUANIDINE UPTAKE; DIFFERENTIAL-DIAGNOSIS; I-131; MIBG; SCINTIGRAPHY; ACCURACY; FAILURE;
D O I
10.1007/s00702-015-1409-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Decreased myocardial uptake of I-123 metaiodobenzylguanidine (MIBG) is an important finding for diagnosis of Parkinson's disease (PD). This study compared I-123 MIBG SPECT and planar imaging with regard to their diagnostic yield for PD. 52 clinically diagnosed PD patients who also had decreased striatal uptake on FP-CIT PET/CT were enrolled. 16 normal controls were also included. All underwent cardiac MIBG planar scintigraphy and SPECT separately. Myocardial I-123 MIBG uptake was interpreted on planar and SPECT/CT images separately by visual and quantitative analysis. The final diagnosis was made by consensus between two readers. Kappa analyses were performed to determine inter-observer agreement for both methods. Sensitivity, specificity, and accuracy were compared with McNemar's test. The sensitivity, specificity, and accuracy were 84.6, 100, and 88.2 % for planar images and 96.2, 100 and 97.1 % for SPECT, respectively, with a significant difference between the two imaging methods (p < 0.031). All inter-observer agreements were almost perfect (planar scintigraphy: kappa = 0.82; SPECT: kappa = 0.93). Heart-to-mediastinum ratios from PD patients with negative planar and positive SPECT scans (group A) and patients with positive planar and positive SPECT scans (group B) were 1.69 +/- 0.16 (1.59-1.85) and 1.41 +/- 0.15 (1.20-1.53), respectively, and showed significant difference (p = 0.023). Lung-to-mediastinum ratios for groups A and B were 2.16 +/- 0.20 (1.96-2.37) and 1.6 +/- 0.19 (1.3-1.78), respectively, and were significantly higher in the former (p = 0.001). I-123 MIBG SPECT has a significantly higher diagnostic performance for PD than planar images. Increased lung uptake may cause false-negative results on planar imaging.
引用
收藏
页码:1421 / 1427
页数:7
相关论文
共 50 条
  • [1] Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease
    Jin-Kyoung Oh
    Eun-Kyoung Choi
    In-Uk Song
    Joong-Seok Kim
    Yong-An Chung
    [J]. Journal of Neural Transmission, 2015, 122 : 1421 - 1427
  • [2] Comparison of planar I-131 MIBG to planar/SPECT I-123 MIBG imaging in the diagnosis of neuroendocrine tumors.
    Rini, JN
    Dunn, WL
    Forstrom, LA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1092 - 1092
  • [3] Metastatic pulmonary pheochromocytomas: Positive I-123 MIBG SPECT with negative I-131 MIBG and equivocal I-123 MIBG planar imaging
    Tsuchimochi, S
    Nakajo, M
    Nakabeppu, Y
    Tani, A
    [J]. CLINICAL NUCLEAR MEDICINE, 1997, 22 (10) : 687 - 690
  • [4] The usefulness of myocardial segmental analysis on I-123 MIBG SPECT in Parkinson's disease
    Kwon, Soo Hyun
    Yoon, Jung Han
    Yoon, Joon-Kee
    Lee, Su Jin
    Jo, Kyung Sook
    Lee, Dong Hyun
    An, Young-Sil
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [5] The Utility of Segmental Analysis in Cardiac I-123 MIBG SPECT in Parkinson’s Disease
    Kwon S.H.
    Yoon J.-K.
    Yoon J.H.
    Lee S.J.
    Jo K.S.
    Lee D.H.
    An Y.-S.
    [J]. Nuclear Medicine and Molecular Imaging, 2015, 49 (4) : 298 - 302
  • [6] A step forward in the use of SPECT imaging with I-123 MIBG
    Mouhamad Abdallah
    Myron C. Gerson
    [J]. Journal of Nuclear Cardiology, 2012, 19 : 16 - 18
  • [7] A step forward in the use of SPECT imaging with I-123 MIBG
    Abdallah, Mouhamad
    Gerson, Myron C.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 16 - 18
  • [8] Quantitative I-123 mIBG SPECT in differentiating abnormal and normal mIBG myocardial uptake
    Ji Chen
    Russell D. Folks
    Liudmila Verdes
    Daya N. Manatunga
    Arnold F. Jacobson
    Ernest V. Garcia
    [J]. Journal of Nuclear Cardiology, 2012, 19 (1) : 92 - 99
  • [9] Decreased myocardial 123I-MIBG uptake in Parkinson's disease
    Iwasa, K
    Nakajima, K
    Yoshikawa, H
    Tada, A
    Taki, J
    Takamori, M
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 1998, 97 (05): : 303 - 306
  • [10] Pseudoneuroblastoma demonstrated by I-123 MIBG SPECT
    Okuyama, C
    Ushijima, Y
    Nakamura, T
    Nishimura, T
    [J]. CLINICAL NUCLEAR MEDICINE, 2001, 26 (05) : 474 - 475