Validation of a non-contact technique for local skin temperature measurements

被引:14
|
作者
George, J. [1 ]
Bensafi, A.
Schmitt, A. M.
Black, D.
Dahan, S. [2 ]
Loche, F. [2 ]
Lagarde, J. M.
机构
[1] Hotel Dieu St Jacques, IRPF, CRP, Skin Res Ctr, F-31025 Toulouse, France
[2] Dermatol Laser Ctr, Toulouse, France
关键词
thermal imaging; lasers; dermatology; rosacea;
D O I
10.1111/j.1600-0846.2008.00309.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Here we propose to quantify local temperature variations using thermal imaging to assess the effect of dermatological lasers. Objectives: To quantify the temperature raise induced by laser application and to differentiate the effects of a potassium titanyl phosphate (KTP) laser and an intense pulsed light (IPL). Methods: A randomized comparative study was performed on 10 adult volunteers with symmetrical rosacea treated by KTP laser or IPL. Skin temperature measurements were performed on inclusion, immediately after laser treatment and 3 min after thermal water application, using a high-resolution (0.08 degrees C) infrared thermal video camera. Results: KTP laser treatment induced a significant rise in local skin temperature whereas no significant change was revealed by the IPL treatment. The infrared camera is a reliable and reproducible technique that allows a follow-up of skin temperature without skin contact. Conclusion: Thermography using an infrared camera could potentially be applied in clinical pharmacology for inflammatory reactions or scarring processes.
引用
下载
收藏
页码:381 / 384
页数:4
相关论文
共 50 条
  • [1] Ensuring the accuracy of non-contact temperature measurements
    Rols, Joris
    Electronics World, 2022, 127 (2013): : 22 - 23
  • [2] Non-contact method for measuring facial skin temperature
    Genno, H
    Saijo, A
    Yoshida, H
    Suzuki, R
    Osumi, M
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 1997, 19 (02) : 147 - 159
  • [3] Non-Contact Thermometer for Improved Air Temperature Measurements
    Pisani, Marco
    Astrua, Milena
    Merlone, Andrea
    SENSORS, 2023, 23 (04)
  • [4] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [5] Validation of a non-contact technique for torque measurements in wind turbines using an enhanced transient FSV approach
    Zhang, G.
    Zappala, D.
    Crabtree, C.
    Donaghy-Spargo, C.
    Hogg, S.
    Duffy, A.
    MEASUREMENT, 2020, 151
  • [6] Non-contact measurements of thermophysical properties of niobium at high temperature
    P.-F. Paradis
    T. Ishikawa
    S. Yoda
    Journal of Materials Science, 2001, 36 : 5125 - 5130
  • [7] A review of non-contact process temperature measurements in steel manufacturing
    Peacock, GR
    THERMOSENSE XXI, 1999, 3700 : 171 - 189
  • [8] Experimental verification of multiband system for non-contact temperature measurements
    Mazikowski, A
    Gnyba, M
    ATOMIC AND MOLECULAR PHYSICS, 2003, 5258 : 198 - 201
  • [9] Non-contact measurements of thermophysical properties of niobium at high temperature
    Paradis, PF
    Ishikawa, T
    Yoda, S
    JOURNAL OF MATERIALS SCIENCE, 2001, 36 (21) : 5125 - 5130
  • [10] Non-contact infrared temperature measurements in dry permafrost boreholes
    Junker, Ralf
    Grigoriev, Mikhail N.
    Kaul, Norbert
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2008, 113 (B4)