Improved Autotransformer Model for Transient Recovery Voltage (TRV) Studies

被引:11
|
作者
Horton, Randy [1 ]
Dugan, Roger C. [2 ]
Wallace, Keith [3 ]
Hallmark, Daryl [3 ]
机构
[1] Elect Power Res Inst, Birmingham, AL 35244 USA
[2] Elect Power Res Inst, Knoxville, TN 37932 USA
[3] So Co Serv Inc, Birmingham, AL 35203 USA
关键词
Electromagnetic transients; power circuit breakers; power transformers; transient recovery voltage; TRANSFORMER WINDINGS; FAULTS; SYSTEM;
D O I
10.1109/TPWRD.2011.2176757
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A three-phase ungrounded fault supplied by a single autotransformer produces a transient recovery voltage (TRV) that is often the worst case for a circuit breaker (CB). This is the so-called "transformer limited fault." The transformer model is extremely important for computing this TRV because it is the key element in the circuit. Unfortunately, data that are needed for more sophisticated autotransformers models (e.g. frequency-response analysis (FRA) data) are not readily available to the study engineer. Consequently, time-domain simulations are generally based on simplified second order (RLC) transformer models whose parameters are estimated from curves provided in IEEE Standard C37.011. This paper provides a more robust autotransformer model that is based on measurement data that are more readily available. The model is validated using FRA data from factory tests. TRV simulation results are compared with those produced by simplified second-order models. In addition, capacitance measurement data for twenty-two 230:115-kV autotransformers are provided to expand the body of capacitance data available to the industry.
引用
收藏
页码:895 / 901
页数:7
相关论文
共 50 条
  • [1] TRV (Transient Recovery Voltage) in High Voltage Current Interruption
    Das, J. C.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (02) : 2165 - 2172
  • [2] ANALYSIS OF TRANSIENT RECOVERY VOLTAGE (TRV) RATING CONCEPTS
    WAGNER, CL
    SMITH, HM
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (11): : 3354 - 3363
  • [3] Effect of transient model of arrester on transient recovery voltage
    Vahidi, B.
    Goodarzi, E.
    Hosseinian, S. H.
    Tavakoli, M. K. Bank
    [J]. TENCON 2007 - 2007 IEEE REGION 10 CONFERENCE, VOLS 1-3, 2007, : 1056 - 1058
  • [4] AUTOTRANSFORMER CIRCUIT-BREAKER TRANSIENT RECOVERY VOLTAGES ASSOCIATED WITH INTERRUPTING LOW-VOLTAGE BUS FAULTS
    VIETOR, GC
    AHRENS, PR
    HARPER, WE
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (08): : 4065 - 4073
  • [5] Studies on the Influences of SFCL on the Transient Recovery Voltage of Circuit Breaker
    Li, Bin
    Ou, Yi Zhe
    [J]. 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 541 - 542
  • [6] Coupling capacitor voltage transformer: A model for electromagnetic transient studies
    Fernandes, D., Jr.
    Neves, W. L. A.
    Vasconcelos, J. C. A.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (02) : 125 - 134
  • [7] Inherent transient recovery voltage of power transformers - A model-based determination procedure
    Hribernik, W
    Graber, L
    Brunke, JH
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) : 129 - 134
  • [8] VOLTAGE ACCELERATION - A BASIC MEASURE OF SEVERITY OF OSCILLATORY TRANSIENT RECOVERY VOLTAGE
    FERGUSON, JS
    HARNER, RH
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (03): : 721 - &
  • [9] An Improved Model of Voltage Source Converters for Power System Harmonic Studies
    Gao, Bo
    Wang, Yang
    Xu, Wilsun
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (04) : 3051 - 3061
  • [10] TRAVELING-WAVE APPROACH TO TRANSIENT RECOVERY VOLTAGE
    COLCLASER, RG
    BUETTNER, DE
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (07): : 1028 - +