Portable Analyzer for Rapid Analysis of Total Protein, Fat and Lactose Contents in Raw Milk Measured by Non-dispersive Short-wave Near-infrared Spectrometry

被引:18
|
作者
Feng Xu-dong [1 ]
Su Rui [1 ]
Xu Nan [1 ]
Wang Xing-hua [1 ]
Yu Ai-min [1 ]
Zhang Han-qi [1 ]
Cao Yan-bo [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
关键词
Portable analyzer; Raw milk; Non-dispersive short-wave near-infrared(NDSWNIR) spectrometry; Multivariate calibration; CHROMATOGRAPHY; SPECTROSCOPY; PRODUCTS; MS;
D O I
10.1007/s40242-013-2191-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel portable analyzer for raw milk quality control during the material purchase at dairy plants was developed, by which the percentages(mass fraction) of main components including total protein, fat, and lactose of an unhomogenized milk sample could be determinated in 1 min with the help of non-dispersive short-wave near-infrared (NDSWNIR) spectrometry in a wavelength range from 600 nm to 1100 nm and multivariate calibration. The analyzer was designed with a single-beam optical system, which comprised a temperature control module, a multi-channel narrow-band light source(16 wavelengths), a glass absorption cell with 15 mm sample thickness, a silicon photodiode detector, several compound lenses and a recorder module. A total of 80 raw milk samples were collected at a dairy farm twice a month for 4 months. The samples were scanned with a common UV-Vis-NIR spectrometer and analyzed according to China GB standard methods. The uninformative variables elimination(UVE) method was carried out on the spectrum data and the percentages of main components of all the samples to choose the peak emitting wavelength of each channel of the light source. Another 90 raw milk samples were collected from the same dairy farm thrice a month for 3 months. The samples were analyzed according to China GB standard methods and with the proposed analyzer. The percentages of the main components and the NDSWNIR absorption data of the samples were used for the construction and validation of the multivariate calibration model with partial least squares(PLS) method. The root-mean-square errors of prediction(RMSEP) of total protein, fat and lactose were 0.201, 0.172 and 0.247 and the coefficients of correlation(R) were 0.932, 0.981 and 0.933, respectively.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 17 条
  • [1] Portable analyzer for rapid analysis of total protein, fat and lactose contents in raw milk measured by non-dispersive short-wave near-infrared spectrometry
    Xu-dong Feng
    Rui Su
    Nan Xu
    Xing-hua Wang
    Ai-min Yu
    Han-qi Zhang
    Yan-bo Cao
    Chemical Research in Chinese Universities, 2013, 29 : 15 - 19
  • [2] Determination of Fat, Protein and DM in Raw Milk by Portable Short-Wave Near Infrared Spectrometer
    Li Xiao-yun
    Wang Jia-hua
    Huang Ya-wei
    Han Dong-hai
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (03) : 665 - 668
  • [3] Short-wave near-infrared spectroscopy of milk powder: Quantitative analysis of fat content
    Wu, Di
    Feng, Shuijuan
    Chen, Xiaojing
    Yang, Haiqing
    He, Yong
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 2, PROCEEDINGS, 2008, : 133 - 136
  • [4] Evaluation of the addition of urea to refrigerated raw milk on the crude protein, milk fat, lactose, and total solids contents determined by mid-infrared spectrometry
    Esteves, E. G.
    Cerqueira, M. M. O. P.
    Fonseca, L. M.
    Leite, M. O.
    Souza, M. R.
    Penna, C. F. A. M.
    Rodrigues, R.
    Abreu, L. R.
    JOURNAL OF DAIRY SCIENCE, 2010, 93 : 333 - 333
  • [5] Building global models for fat and total protein content in raw milk based on historical spectroscopic data in the visible and short-wave near infrared range
    Melenteva, Anastasiia
    Galyanin, Vladislav
    Savenkova, Elena
    Bogomolov, Andrey
    FOOD CHEMISTRY, 2016, 203 : 190 - 198
  • [6] Short-wave near-infrared spectroscopy of milk powder for brand identification and component analysis
    Wu, D.
    Feng, S.
    He, Y.
    JOURNAL OF DAIRY SCIENCE, 2008, 91 (03) : 939 - 949
  • [7] Short-wave near-infrared spectroscopy analysis of major compounds in milk powder and wavelength assignment
    Wu, Di
    He, Yong
    Feng, Shuijuan
    ANALYTICA CHIMICA ACTA, 2008, 610 (02) : 232 - 242
  • [8] MULTIVARIATE CALIBRATION FOR PROTEIN, CHOLESTEROL AND TRIGLYCERIDES IN HUMAN PLASMA USING SHORT-WAVE NEAR-INFRARED SPECTROMETRY
    BITTNER, A
    MARBACH, R
    HEISE, HM
    JOURNAL OF MOLECULAR STRUCTURE, 1995, 349 : 341 - 344
  • [9] Determination of fat, protein, and lactose in raw milk by Fourier transform infrared spectroscopy and by analysis with a conventional filter-based milk analyzer
    Lefier, D
    Grappin, R
    Pochet, S
    JOURNAL OF AOAC INTERNATIONAL, 1996, 79 (03) : 711 - 717
  • [10] Development of a new measurement unit (MilkSpec-1) for rapid determination of fat, lactose, and protein in raw milk using near-infrared transmittance spectroscopy
    Woo, YA
    Terazawa, Y
    Chen, JY
    Iyo, C
    Terada, F
    Kawano, S
    APPLIED SPECTROSCOPY, 2002, 56 (05) : 599 - 604