A method for measuring oxygen distributions in tissue using frequency domain phosphorometry

被引:34
|
作者
Vinogradov, SA [1 ]
Fernandez-Seara, MA [1 ]
Dupan, BW [1 ]
Wilson, DF [1 ]
机构
[1] Univ Penn, Sch Med, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
来源
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY | 2002年 / 132卷 / 01期
关键词
phosphorescence oxygen; maximum entropy method; lifetime distributions; luminescence quenching; oxygen distributions; heterogeneous objects; phosphorescence instrumentation;
D O I
10.1016/S1095-6433(01)00541-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Phosphorescence lifetime of phosphors dissolved in biological fluids is dependent on the local oxygen concentration. When phosphor is added to the blood in vivo there is a distribution of lifetimes due to the distribution of oxygen concentrations in the blood of the sampled tissue volume. The distribution of oxygen can be assessed non-invasively and in practically real-time using frequency domain time-resolved phosphorometry. Here we describe a multi-frequency system for measurements of oxygen distributions in tissue in vivo. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [1] Frequency domain instrument for measuring phosphorescence lifetime distributions in heterogeneous samples
    Vinogradov, SA
    Fernandez-Searra, MA
    Dugan, BW
    Wilson, DF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08): : 3396 - 3406
  • [2] The application of frequency-domain method in measuring amplitude-frequency characteristic
    Hu, MC
    Ye, WY
    Ye, WW
    Li, ZB
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 867 - 870
  • [3] Method for measuring settling phenomena by means of frequency domain instrumentation
    D'Apuzzo, M.
    D'Arco, M.
    Liccardo, A.
    Vadursi, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [4] Measuring Tissue Oxygen Saturation Using NIR Spectroscopy
    Aslinur-Sircan-Kucuksayan
    Uyuklu, Mehmet
    Canpolat, Murat
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129
  • [5] A PRECISION METHOD FOR MEASURING THE COMPLEX PERMITTIVITY OF SOLID TISSUE IN THE FREQUENCY-DOMAIN BETWEEN 2 AND 18 GHZ
    STEEL, M
    SHEPPARD, RJ
    GRANT, EH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (01): : 30 - 34
  • [6] Measuring modal delays of few-mode fibers using frequency-domain method
    Li, Kangmei
    Chen, Xin
    Hurley, Jason
    Stone, Jeffery
    Li, Ming-Jun
    OPTICAL FIBER TECHNOLOGY, 2021, 62
  • [7] Test of a frequency independent method for measuring bulk soil salinity using time domain reflectometry
    Bonnell, Robert B.
    Broughton, Robert S.
    Gomaa, Fathy
    ICID Bulletin (International Commission on Irrigation and Drainage), 1993, 42 (02):
  • [8] Quantitative determination of the tissue oxygen saturation using frequency-domain near-infrared spectroscopy
    Zhao, Jun
    Ding, Haishu
    Teng, Yichao
    Guangzi Xuebao/Acta Photonica Sinica, 2005, 34 (03): : 386 - 389
  • [9] Simultaneously Measuring Group Delays, Chromatic Dispersion and Skews of Multicore Fibers Using a Frequency Domain Method
    Chen, Xin
    Li, Kangmei
    Hurley, Jason
    Li, Ming-Jun
    2022 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION (OFC), 2022,
  • [10] A METHOD OF MEASURING TIME DISTRIBUTIONS
    KONDRATEV, VP
    KRASNOV, LV
    YATSYSHIN, IG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (05) : 1192 - 1195