Prism use in adult diplopia

被引:17
|
作者
Gunton, Kammi B. [1 ]
Brown, A'sha [2 ]
机构
[1] Wills Eye Inst, Dept Pediat Ophthalmol, Philadelphia, PA 19107 USA
[2] Drexel Univ, Coll Med, Philadelphia, PA 19104 USA
关键词
adult; diplopia; Fresnel; prism; NERVE PALSY; CONVERGENCE-INSUFFICIENCY; STRABISMUS; MANAGEMENT; FRACTURES; BASE;
D O I
10.1097/ICU.0b013e3283567276
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review Prismatic correction to restore binocularity in adult diplopia can be challenging. This review summarizes the results of prismatic correction in adults based on the cause of diplopia. Recent findings Satisfaction with prismatic correction is achieved in approximately 80% of all adult patients with diplopia when combining the causes. Of patients with vertical diplopia, skew deviation and fourth nerve palsy have the highest satisfaction rates, 100 and 92%, respectively. Patients with thyroid eye disease and orbital blowout fractures associated with diplopia had the lowest satisfaction rates, 55 and 8%, respectively. With regard to horizontal deviations, patients with decompensated childhood strabismus with a combination of horizontal and vertical deviations and patients with convergence insufficiency had the lowest satisfaction rates, 71 and 50%, respectively. Summary Careful selection of patients for prismatic correction, management of patient's expectations, and continued follow-up to monitor the symptoms are critical to the successful use of prisms.
引用
收藏
页码:400 / 404
页数:5
相关论文
共 50 条
  • [1] Alleviating vertical diplopia through contact lenses without the use of prism
    Migneco, Mary K.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (05): : 297 - 298
  • [2] The prism as an aid to diagnosis in paralytic diplopia.
    Ferguson, RB
    LANCET, 1909, 2 : 228 - 229
  • [3] Evaluation of the adult with diplopia
    Ellis, FD
    AT THE CROSSINGS: PEDIATRIC OPHTHALMOLOGY AND STRABISMUS, 2004, : 157 - 168
  • [4] FRESNEL PRISM CORRECTION FOR TRAUMA-INDUCED DIPLOPIA
    WOO, GC
    LOVASIK, JV
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1985, 5 (01) : 59 - 62
  • [5] CASE-REPORT - FRESNEL PRISM FOR CONSTANT DIPLOPIA
    BADER, DA
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1983, 60 (05): : 410 - 411
  • [6] Therapeutic Outcomes of Prism Glasses for Diplopia Unrelated to Strabismus Surgery
    Hwang, Hye Seong
    Choi, Mi Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (08): : 766 - 772
  • [7] THE RISK OF POSTOPERATIVE DIPLOPIA IN ADULT STRABISMUS
    BENEISH, R
    FLANDERS, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 863 - 863
  • [8] Successful Treatment of Diplopia With Prism Improves Health-Related Quality of Life
    Hatt, Sarah R.
    Leske, David A.
    Liebermann, Laura
    Holmes, Jonathan M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1209 - 1213
  • [9] Adult reference values of the computerized diplopia test
    Zhou, Ling-Yun
    Liu, Tie-Juan
    Li, Xue-Mei
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (11) : 1646 - 1650
  • [10] Adult reference values of the computerized diplopia test
    Ling-Yun Zhou
    Tie-Juan Liu
    Xue-Mei Li
    International Journal of Ophthalmology, 2016, (11) : 1646 - 1650