Vibration analysis of the Thomson Scattering diagnostics optical transmission system on EAST Tokamak

被引:1
|
作者
Shao Chunqiang [1 ]
Zang Qing [1 ]
Zhao Junyu [1 ]
Hu Ailan [1 ]
Han Xiaofeng [1 ]
Chen Hui [1 ]
He Liangliang [1 ]
Wang Tengfei [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
关键词
Thomson Scattering; measurement error; vibration analysis; spectrum analyzer; speed sensor; vibration isolation efficiency;
D O I
10.1117/12.2069768
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A series of vibration source from the EAST tokamak complicated experimental environment would result in the laser path misalignment and the collected scattered laser signal attenuation, which leads to a measurement error of the Thomson Scattering (TS) diagnostics system. Two methods have been designed for the vibration analysis of the TS diagnostics optical transmission system, a passive one and an active one. The optical transmission system contains of a double deck optical table with 4 reflectors and a photon collection system. The vibration analysis includes 4 points of reflectors along the laser path, 1 point of the photon collection system, and the ground of EAST experimental hall. The passive method used a vibration spectrum analyzer and 7 vertical speed sensors measuring the standard deviation of the vibration noise, which refers to the virtual value of vibration, and a data analysis system. The active method used a hammer to simulate the vibration source of the experimental hall ground, and 15 accelerometers to measure the three-dimensional vibration spectrum of 5 points along the optical transmission system. The vibration isolation efficiency (IE) of the optical transmission system has been presented, and the vibration asynchrony of the 5 points also has been observed. The results of two methods are comparatively studied, and the active one is considered to be more credible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multiple Laser System for High-Resolution Thomson Scattering Diagnostics on the EAST Tokamak
    Han, X.
    Hu, A.
    Li, D.
    Xiao, S.
    Tian, B.
    Zang, Q.
    Zhao, J.
    Hsieh, C.
    Gong, X.
    Hu, L.
    Xu, G.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (02) : 406 - 409
  • [2] Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak
    Bohm, P.
    Sestak, D.
    Bilkova, P.
    Aftanas, M.
    Weinzettl, V.
    Hron, M.
    Panek, R.
    Baillon, L.
    Dunstan, M. R.
    Naylor, G.
    Walsh, M. J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [3] Thomson scattering diagnostics in the Globus-M tokamak
    Tolstyakov, S. Yu.
    Gusev, V. K.
    Kochergin, M. M.
    Kurskiev, G. S.
    Mukhin, E. E.
    Petrov, Yu. V.
    Razdobarin, G. T.
    Semenov, V. V.
    Kamach, Yu. E.
    Kozlovskii, E. N.
    Pirozhkov, Yu. B.
    Shapiro, L. L.
    [J]. TECHNICAL PHYSICS, 2006, 51 (07) : 846 - 852
  • [4] Timing and triggering of the Thomson scattering diagnostics on the COMPASS tokamak
    Mikulin, O.
    Hron, M.
    Bohm, P.
    Naylor, G.
    Bilkova, P.
    Janky, F.
    Salasek, J.
    Panek, R.
    [J]. FUSION ENGINEERING AND DESIGN, 2014, 89 (05) : 693 - 697
  • [5] Thomson scattering diagnostics in the Globus-M tokamak
    S. Yu. Tolstyakov
    V. K. Gusev
    M. M. Kochergin
    G. S. Kurskiev
    E. E. Mukhin
    Yu. V. Petrov
    G. T. Razdobarin
    V. V. Semenov
    Yu. E. Kamach
    E. N. Kozlovskiĭ
    Yu. B. Pirozhkov
    L. L. Shapiro
    [J]. Technical Physics, 2006, 51 : 846 - 852
  • [6] THE FRASCATI TOKAMAK UPGRADE THOMSON SCATTERING SYSTEM - THE OPTICAL AND SPECTRAL-ANALYSIS EQUIPMENTS
    PIZZOLATI, P
    BRICCOLA, M
    GARBI, M
    GOLINELLI, E
    MEZZETTI, S
    GIORGETTI, G
    MOLESINI, G
    BARTIROMO, R
    BRUSADIN, A
    GIOVANNOZZI, E
    ORSITTO, F
    SANTI, D
    FERRARIO, A
    BASSAN, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 4403 - 4409
  • [7] THOMSON SCATTERING SYSTEM OF THE ERASMUS TOKAMAK
    DESOPPERE, E
    VANOOST, G
    [J]. REVUE DE PHYSIQUE APPLIQUEE, 1983, 18 (12): : 803 - 808
  • [8] Analysis of the New Thomson Scattering Diagnostic System on WEST Tokamak
    Chelihi, Brahim
    Colledani, Gilles
    Doceul, Louis
    Lefevre, Nicolas
    Batal, Tristan
    Garitta, Silvia
    Faisse, Frederic
    Verger, Jean-Marc
    Bec, Antony
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [9] Thomson scattering diagnostics at the Globus-M2 tokamak
    Zhiltsov, N.S.
    Kurskiev, G.S.
    Tolstyakov, S.Yu.
    Solovey, V.A.
    Koval, A.N.
    Tkachenko, E.E.
    Aleksandrov, S.E.
    Bakharev, N.N.
    Balachenkov, I.M.
    Bazhenov, A.N.
    Chernakov, P.V.
    Filippov, S.V.
    Gusev, V.K.
    Khromov, N.A.
    Kiselev, E.O.
    Kornev, A.F.
    Krikunov, S.V.
    Makarov, A.M.
    Minaev, V.B.
    Miroshnikov, I.V.
    Mukhin, E.E.
    Novokhatsky, A.N.
    Patrov, M.I.
    Petrov, Yu.V.
    Ponomarenko, A.M.
    Sakharov, N.V.
    Shchegolev, P.B.
    Shulyatiev, K.D.
    Skrekel, O.M.
    Solokha, V.V.
    Telnova, A.Yu.
    Tokarev, V.A.
    Tukhmeneva, E.A.
    Varfolomeev, V.I.
    Voronin, A.V.
    Yashin, A.Yu.
    [J]. Fusion Engineering and Design, 2025, 211
  • [10] The Thomson scattering system on the lithium tokamak experiment
    Strickler, T.
    Majeski, R.
    Kaita, R.
    LeBlanc, B.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):