Absorption spectroscopy in microfluidic flow cells using a metal clad leaky waveguide device with a porous gel waveguide layer

被引:19
|
作者
Gupta, Ruchi [1 ]
Bastani, Behnam [1 ]
Goddard, N. J. [1 ]
Grieve, Bruce [2 ]
机构
[1] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester, Lancs, England
[2] Univ Manchester, Sch Elect & Elect Engn, Manchester, Lancs, England
关键词
RING-DOWN SPECTROSCOPY; SINGLE DEVICE; SEAWATER PH; SENSOR; FABRICATION; DETECTOR; SILICON;
D O I
10.1039/c2an35898k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Broadband absorption spectroscopy is advantageous because the full spectral profile of an analyte can permit identification of species. This work for the first time investigates the feasibility of a metal clad leaky waveguide (MCLW) device to obtain an absorption spectrum of an analyte of interest, methylene blue, using a white light source in a microfluidic flow cell. The MCLW device comprises a porous low refractive index gel, agarose, deposited on a titanium coated glass slide. The device was capable of detecting 2.3 mM of methylene blue at a wavelength of 650 nm. The corresponding minimum detectable absorbance is 1.6 x 10(-1) cm(-1). In comparison to commonly used detection devices the MCLW is simpler, robust, easier to fabricate and can be easily interfaced to microfluidic devices. It was also possible to store the MCLW devices dry for up to a year and rehydrate them in 30 s to a working condition.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 9 条
  • [1] A novel leaky waveguide grating (LWG) device for evanescent wave broadband absorption spectroscopy in microfluidic flow cells
    Gupta, Ruchi
    Goddard, Nick J.
    [J]. ANALYST, 2013, 138 (06) : 1803 - 1811
  • [2] Immunosensing using a metal clad leaky waveguide biosensor for clinical diagnosis
    Im, Won Joo
    Kim, Bo Bae
    Byun, Ju Young
    Kim, Hyoung Min
    Kim, Min-Gon
    Shin, Yong-Beom
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 288 - 294
  • [3] Sensitivity enhancement of metal clad planar waveguide sensor using metamaterial layer as a guiding layer
    Pal, Sarika
    Prajapati, Y. K.
    Saini, J. P.
    Singh, Vivek
    [J]. OPTIK, 2015, 126 (14): : 1372 - 1376
  • [4] A polymeric waveguide resonant mirror (RM) device for detection in microfluidic flow cells
    Gupta, Ruchi
    Goddard, Nick J.
    [J]. ANALYST, 2013, 138 (11) : 3209 - 3215
  • [5] Analysis of Metal Clad Waveguide Sensor using Metamaterial as Guiding Layer for Gold Cladding
    Upadhyay, Anurag
    [J]. 2018 INTERNATIONAL CONFERENCE ON COMPUTATIONAL AND CHARACTERIZATION TECHNIQUES IN ENGINEERING & SCIENCES (CCTES), 2018, : 227 - 229
  • [6] Metal-clad waveguide sensor using a left-handed material as a core layer
    Kullab, Hani M.
    Taya, Sofyan A.
    El-Agez, Taher M.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2012, 29 (05) : 959 - 964
  • [7] Broadband absorption spectroscopy for rapid pH measurement in small volumes using an integrated porous waveguide
    Gupta, Ruchi
    Goddard, Nick J.
    [J]. ANALYST, 2017, 142 (01) : 169 - 176
  • [8] Metal-Clad Waveguide Resonance Sensor Using a Mesoporous TiO2 Thin Film as the Chemical Sensitive Core Layer
    Wan, Xiumei
    Lu, Dan-feng
    Gao, Ran
    Cheng, Jin
    Qi, Zhi-mei
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (35): : 19173 - 19181
  • [9] EFFECTS OF A BUFFER LAYER ON TM MODES IN A METAL-CLAD OPTICAL-WAVEGUIDE USING TI-DIFFUSED LINBO3 C-PLATE
    MASUDA, M
    KOYAMA, J
    [J]. APPLIED OPTICS, 1977, 16 (11) : 2994 - 3000