A new effective on chip electromembrane extraction coupled with high performance liquid chromatography for enhancement of extraction efficiency

被引:49
|
作者
Asl, Yousef Abdossalami [1 ]
Yamini, Yadollah [1 ]
Seidi, Shahram [2 ]
Ebrahimpour, Behnam [1 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[2] KN Toosi Univ Technol, Fac Chem, Dept Analyt Chem, Tehran, Iran
关键词
On chip extraction; Electromembrane; High performance liquid chromatography; Nortriptyline; Amitriptyline; Urine; IMMISCIBLE ORGANIC-SOLVENTS; PHASE MICROEXTRACTION; MICROFLUIDIC CHIP; PULSED ELECTROMEMBRANE; WASTE-WATER; PRECONCENTRATION; AMITRIPTYLINE; PLASMA; COMBINATION; SYSTEM;
D O I
10.1016/j.aca.2015.09.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present research, an effective on chip electromembrane extraction (CEME) coupled with high performance liquid chromatography was presented for analysis of nortriptyline (NOR) and amitriptyline (AMI) as basic model analytes from urine samples. The chip consists of two polymethyl methacrylate (PMMA) parts with two craved microfluidic channels in each part. These channels were used as flow path for the sample solution and a thin compartment for the acceptor phase. A porous polypropylene sheet membrane impregnated with an organic solvent was placed between two parts of chip device to separate the channels. Two platinum electrodes were mounted at the bottom of these channels that were connected to a power supply providing the electrical driving force for migration of ionized analytes from sample solution through the porous sheet membrane into the acceptor phase. This new setup provides effective and reproducible extractions with low volume of sample solution. Efficient parameters on CEME of the model analytes were optimized using one variable at a time method. Under the optimized conditions, the calibration curve was linear in the range of 10.0-500 mg L-1 with coefficient of determination (r(2)) more than 0.9902. The relative standard deviations (RSDs %) for extraction and determination of the analytes were less than 6.8% based on six replicate measurements. LODs less than 4.0 mg L-1 were obtained for both of the model analytes. The preconcentration factors higher than 17.0-fold were obtained. The results demonstrated that CEME would be used efficiently for extraction and determination of AMI and NOR from urine samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [1] Sensitive determination of ethosuximide in human fluids by electromembrane extraction coupled with high performance liquid chromatography ultraviolet spectroscopy
    Nabizadeh, Hassan
    Mohammadi, Ali
    Dolatabadi, Roshanak
    Nojavan, Saeed
    Vahabizad, Fahimeh
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2023, 70 (01) : 76 - 86
  • [2] Quantitative analysis of clonidine and ephedrine by a microfluidic system: On-chip electromembrane extraction followed by high performance liquid chromatography
    Baharfar, Mahroo
    Yamini, Yadollah
    Seidi, Shahram
    Karami, Monireh
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1068 : 313 - 321
  • [3] Determination of hydroxypolycyclic aromatic hydrocarbons in urine by electromembrane extraction coupled with liquid chromatography
    Gao, Haidong
    Gao, Shucai
    Lv, Ming
    Liu, Yeru
    Yao, Jingjing
    Liu, Hongwei
    Wang, Fayun
    Chen, Mantang
    Wan, Libin
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1736
  • [4] Subcritical water extraction coupled to high-performance liquid chromatography
    Yang, Y
    Li, B
    ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1491 - 1495
  • [5] Subcritical water extraction coupled to high-performance liquid chromatography
    Department of Chemistry, East Carolina University, 205 Flanagan, Greenville, NC 27858, United States
    Anal. Chem., 8 (1491-1495):
  • [6] Determination of phenazopyridine in biological fluids using electromembrane extraction followed by high-performance liquid chromatography
    Fotouhi, Lida
    Yamini, Yadollah
    Hosseini, Razieh
    Rezazadeh, Maryam
    CANADIAN JOURNAL OF CHEMISTRY, 2015, 93 (07) : 702 - 707
  • [7] Speciation of chromium in environmental samples by dual electromembrane extraction system followed by high performance liquid chromatography
    Safari, Meysam
    Nojavan, Saeed
    Davarani, Saied Saeed Hosseiny
    Morteza-Najarian, Amin
    ANALYTICA CHIMICA ACTA, 2013, 789 : 58 - 64
  • [8] Electromembrane Extraction of Organic Acid Compounds in Biological Samples Followed by High-Performance Liquid Chromatography
    Khajeh, Mostafa
    Shakeri, Mohammad
    Natavan, Zahra Bameri
    Moghaddam, Zahra Safaei
    Bohlooli, Mousa
    Moosavi-Movahedi, A. A.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1217 - 1221
  • [9] Electromembrane extraction followed by high performance liquid chromatography: an efficient method for extraction and determination of morphine, oxymorphone, and methylmorphine from urine samples
    Yamini, Yadollah
    Pourali, Au
    Seidi, Shahram
    Rezazadeh, Maryam
    ANALYTICAL METHODS, 2014, 6 (15) : 5554 - 5565
  • [10] ULTRASONIC EXTRACTION COUPLED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR PARABENS ANALYSIS IN COSMETICS
    Liu, Z. M.
    Xu, F. H.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 119 : 52 - 52