Comparison of clinical and radiographic status around dental implants placed in patients with and without prediabetes: 1-year follow-up outcomes

被引:29
|
作者
Al Amri, Mohammad D. [1 ]
Abduljabbar, Tariq S. [1 ]
Al-Kheraif, Abdulaziz A. [2 ]
Romanos, Georgios E. [3 ,4 ]
Javed, Fawad [5 ]
机构
[1] King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169, Riyadh 11545, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Dent Hlth, Riyadh, Saudi Arabia
[3] SUNY Stony Brook, Sch Dent Med, Dept Periodontol, Stony Brook, NY 11794 USA
[4] Johann Wolfgang Univ, Dept Oral Surg & Implant Dent, Frankfurt, Germany
[5] Univ Rochester, Eastman Inst Oral Hlth, Dept Gen Dent, Rochester, NY USA
关键词
clinical parameters; dental implant; marginal bone loss; prediabetes; success rate; TYPE-2; DIABETES-MELLITUS; PERCEIVED ORAL-HEALTH; GLYCEMIC CONTROL; PERIODONTAL PARAMETERS; SOCIOECONOMIC-STATUS; SURGICAL-PROCEDURES; CIGARETTE-SMOKING; BONE LOSS; DISEASE; IMPACT;
D O I
10.1111/clr.12788
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveWe hypothesized that peri-implant soft tissue inflammation is worse and peri-implant marginal bone loss (MBL) is higher around dental implants placed in patients with prediabetes compared to healthy subjects. The aim of the present 12-month follow-up study was to compare the clinical and radiographic status around dental implants placed in patients with and without prediabetes. Material and methodsTwelve patients with medically diagnosed prediabetes (Group-1) and 12 controls (Group-2) were included. All patients were indicated for single tooth maxillary or mandibular premolar replacement with the adjacent teeth intact. Success of the restored implants was assessed by comparing clinical (peri-implant bleeding on probing [BOP], and probing pocket depth [PPD]) and radiographic (peri-implant MBL) parameters at baseline and at 12-months follow-up. Statistical analysis was performed using one-way analysis of variance, and P-values <0.05 were considered statistically significant. ResultsAt 12months of follow-up, there was no clinical evidence for the presence of plaque, BOP and peri-implant pockets with PPD4mm in both groups. At 12-month follow-up, the mean MBL among implants placed in groups 1 and 2 were 0.2 +/- 0.1mm and 0.1 +/- 0.01mm, respectively. Overall, the periodontal status (PI, BOP and PPD4mm) at 12-month follow-up was comparable among patients in both groups. ConclusionWithin the limitations of this study, it is concluded that dental implants inserted in prediabetic and healthy patients have similar success rates and remain clinically and radiographically stable after 1-year follow-up.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 50 条
  • [1] A 1-Year Clinical and Radiographic Study on Hydrophilic Dental Implants Placed with and without Bone Augmentation Procedures
    Zumstein, Thomas
    Sennerby, Lars
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (03) : 498 - 506
  • [2] Laterally placed expandable interbody spacers improve radiographic and clinical outcomes: A 1-year follow-up study
    Huang, Zheng
    Li, Yan Michael
    Towner, James
    Li, Yan Icy
    Edsall, Amber
    Ledonio, Charles
    [J]. INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2020, 20
  • [3] A Comparison of Clinical Outcomes for Implants Placed in Fresh Extraction Sockets Versus Healed Sites in Periodontally Compromised Patients: A 1-Year Follow-up Report
    Deng, Feilong
    Zhang, Hua
    Zhang, Hui
    Shao, Haibin
    He, Qifen
    Zhang, Peifen
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 1036 - 1040
  • [4] A 1-year follow-up of implants of differing surface roughness placed in rabbit bone
    Wennerberg, A
    Ektessabi, A
    Albrektsson, T
    Johansson, C
    Andersson, B
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (04) : 486 - 494
  • [5] A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up
    Borgonovo, Andrea Enrico
    Ferrario, Susanna
    Maiorana, Carlo
    Vavassori, Virna
    Censi, Rachele
    Re, Dino
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [6] Comparative Effectiveness of Laterally Placed Expandable versus Static Interbody Spacers: A 1-Year Follow-Up Radiographic and Clinical Outcomes Study
    Li, Yan Michael
    Frisch, Richard Francis
    Huang, Zheng
    Towner, James Edward
    Li, Yan Icy
    Edsall, Amber Lynn
    Ledonio, Charles
    [J]. ASIAN SPINE JOURNAL, 2021, 15 (01) : 89 - 96
  • [7] Implants placed in fresh extraction sockets in the maxilla: clinical and radiographic outcomes from a 3-year follow-up examination
    Sanz, Mariano
    Cecchinato, Denis
    Ferrus, Jorge
    Salvi, Giovanni E.
    Ramseier, Christoph
    Lang, Niklaus P.
    Lindhe, Jan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (03) : 321 - 327
  • [8] Comparison of peri-implant clinical and radiographic status around short (6 mm in length) dental implants placed in cigarette-smokers and never-smokers: Six-year follow-up results
    Abduljabbar, Tariq
    Al-Hamoudi, Nawwaf
    Al-Sowygh, Zeyad H.
    Alajmi, Mohammed
    Javed, Fawad
    Vohra, Fahim
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (01) : 21 - 25
  • [9] Comparison of clinical and radiographic status of platform-switched implants placed in patients with and without type 2 diabetes mellitus: a 24-month follow-up longitudinal study
    Al Amri, Mohammad D.
    Abduljabbar, Tariq S.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (02) : 226 - 230
  • [10] Clinical and radiographic peri-implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: A 3-year follow-up study
    Akram, Zohaib
    Vohra, Fahim
    Sheikh, Saeed A.
    Albaijan, Refal
    Bukhari, Ishfaq A.
    Hussain, Mudassir
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 775 - 780