A method for the production of composite scintillators for dosimetry in diagnostic radiology

被引:9
|
作者
Nowotny, R. [1 ]
Taubeck, A. [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, A-1090 Vienna, Austria
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 06期
关键词
ENERGY BEAM DOSIMETRY; PLASTIC SCINTILLATOR; OPTICAL-FIBERS; DOSE PROFILES; RADIOLUMINESCENCE; MAMMOGRAPHY; DETECTORS; CT;
D O I
10.1088/0031-9155/54/6/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Plastic scintillators are used in the dosimetry of photons in radiotherapy. Their use in diagnostic radiology is affected by the drop in response at lower photon energies due to inadequate composition ( effective atomic number) and chemical quenching. To compensate for this deficiency, a method for the production of composite polystyrene-based plastic scintillators was devised allowing the incorporation of inorganic scintillation powder. Disks of 10 mm diameter and 1 mm thickness optimized for a flat energy response referred to kerma in air were produced using CaWO(4), ZnS: Ag and CaF(2):Eu as additives. In an HVL range of 2.26-13.69 mmAl, the response was within an interval of +/- 2.8% for CaF(2):Eu as additive, +/- 3.2% for CaWO(4) and +/- 10.9% for ZnS:Ag, respectively. The response of a commercial plastic scintillator (BC470) stays within +/- 13.6%. The temperature dependence of the composite scintillator using CaF(2): Eu is lowest with a variation of + 3.7% to - 3.6% in an interval from 5 degrees C to 45 degrees C. The deficiency in photon absorption at lower energies due to the effective atomic number is reduced but not fully compensated by the additive scintillators. The optimized concentrations were established for the scintillator dimensions used.
引用
收藏
页码:1457 / 1468
页数:12
相关论文
共 50 条
  • [1] Dosimetry in diagnostic radiology
    Meghzifene, Ahmed
    Dance, David R.
    McLean, Donald
    Kramer, Hans-Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 11 - 14
  • [2] An approach to diagnostic radiology dosimetry
    Donald McLean
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 615 - 618
  • [3] An approach to diagnostic radiology dosimetry
    McLean, Donald
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (04) : 615 - 618
  • [4] Radiation dosimetry in diagnostic radiology
    Huda, W
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) : 1487 - 1488
  • [5] DOSIMETRY IN DIAGNOSTIC-RADIOLOGY
    不详
    PTB-MITTEILUNGEN, 1991, 101 (04): : 285 - 285
  • [6] Dosimetry are diagnostic radiology employees "category A"? Or "should operational dosimetry in diagnostic radiology departments be mandatory"
    Cordoliani, YS
    Aubert, B
    JOURNAL DE RADIOLOGIE, 2002, 83 (09): : 1020 - 1022
  • [7] Thermoluminescent dosimetry in veterinary diagnostic radiology
    Hernandez-Ruiz, L.
    Jimenez-Flores, Y.
    Rivera-Montalvo, T.
    Arias-Cisneros, L.
    Mendez-Aguilar, R. E.
    Uribe-Izquierdo, P.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 44 - 47
  • [8] Diagnostic radiology dosimetry: Status and trends
    Rivera-Montalvo, T.
    APPLIED RADIATION AND ISOTOPES, 2016, 117 : 74 - 81
  • [9] Patient dosimetry in paediatric diagnostic radiology
    Borisova, R.
    Ingilizova, Ch.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 155 - 159
  • [10] LiF:W as a scintillator for dosimetry in diagnostic radiology
    Nowotny, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2599 - 2611