Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

被引:40
|
作者
Shin, Taehoon [1 ]
Hu, Houchun H. [1 ]
Pohost, Gerald M. [1 ,2 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
关键词
D O I
10.1186/1532-429X-10-57
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determining the size of defects, and to demonstrate the feasibility of 3D MPI in healthy volunteers at 3 Tesla. Methods: A heart phantom was used to compare the accuracy of 3D and 2D multi-slice MPI in estimating the volume fraction of seven rubber insets which simulated transmural myocardial perfusion defects. Three sets of cross-sectional planes were acquired for 2D multi-slice imaging, where each set was shifted along the partition encoding direction by +/- 10 mm. 3D first-pass contrast-enhanced (0.1 mmol/kg Gd-DTPA) MPI was performed in three volunteers with sensitivity encoding for six-fold acceleration. The upslope of the myocardial time-intensity-curve and peak SNR/CNR values were calculated. Results: Mean/standard deviation of errors in estimating the volume fraction across the seven defects were -0.44/1.49%, 2.23/2.97%, and 2.59/3.18% in 3D, 2D 4-slice, and 2D 3-slice imaging, respectively. 3D MPI performed in healthy volunteers produced excellent quality images with whole left ventricular (LV) coverage. Peak SNR/CNR was 57.6 +/- 22.0/37.5 +/- 19.7 over all segments in the first eight slices. Conclusion: 3D performed better than 2D multi-slice MPI in estimating the size of perfusion defects in phantoms. Highly accelerated 3D MPI at 3T was feasible in volunteers, allowing whole LV coverage with excellent image quality and high SNR/CNR.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study
    Taehoon Shin
    Houchun H Hu
    Gerald M Pohost
    Krishna S Nayak
    [J]. Journal of Cardiovascular Magnetic Resonance, 10
  • [2] 1125 Spiral first-pass myocardial perfusion imaging at 3 Tesla: feasibility study
    Taehoon Shin
    Kyunghyun Sung
    Gerald M Pohost
    Krishna S Nayak
    [J]. Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [3] Editorial for "First-Pass Myocardial Perfusion With Increased Anatomic Coverage at 3T Using Autocalibrated Multiband Imaging"
    Arai, Hideo
    Kawakubo, Masateru
    Kadokami, Toshiaki
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (01) : 189 - 190
  • [4] First-pass myocardial perfusion MR imaging with interleaved notched saturation: Feasibility study
    Slavin, GS
    Wolff, SD
    Gupta, SN
    Foo, TKF
    [J]. RADIOLOGY, 2001, 219 (01) : 258 - 263
  • [5] Parallel imaging for first-pass myocardial perfusion
    Irwan, Roy
    Lubbers, Daniel D.
    van der Vleuten, Pieter A.
    Kappert, Peter
    Gotte, Marco J. W.
    Sijens, Paul E.
    [J]. MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 678 - 683
  • [6] An initial study on the feasibility of diagnosing myocardial ischemia with CT first-pass myocardial perfusion imaging at rest
    汪奇
    [J]. China Medical Abstracts (Internal Medicine), 2013, 30 (02) : 82 - 83
  • [7] Steady-state first-pass perfusion (SSFPP): A 3D TWIST in myocardial first-pass perfusion imaging
    Shivraman Giri
    Hui Xue
    Abdul Wattar
    Yu Ding
    Randall M Kroeker
    Gerhard Laub
    Peter Kellman
    Sven Zuehlsdorff
    Subha V Raman
    Orlando P Simonetti
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [8] Mouse Myocardial First-Pass Perfusion MR Imaging
    Coolen, Bram F.
    Moonen, Rik P. M.
    Paulis, Leonie E. M.
    Geelen, Tessa
    Nicolay, Klaas
    Strijkers, Gustav J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1658 - 1663
  • [9] Steady-State First-Pass Perfusion (SSFPP): A New Approach to 3D First-Pass Myocardial Perfusion Imaging
    Giri, Shivraman
    Xue, Hui
    Maiseyeu, Andrei
    Kroeker, Randall
    Rajagopalan, Sanjay
    White, Richard D.
    Zuehlsdorff, Sven
    Raman, Subha V.
    Simonetti, Orlando P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 133 - 144
  • [10] Myocardial First-Pass Perfusion With Increased Anatomic Coverage at 3 T Using Autocalibrated Multiband Imaging
    Zou, Lixian
    Zheng, Yuan
    Chen, Jialing
    Ding, Yu
    Liu, Hui
    Liu, Yubao
    Xu, Jian
    Zheng, Hairong
    Liu, Xin
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (01) : 178 - 188