Results of pseudo-static tests with cyclic horizontal load on cast in situ sandwich squat concrete walls

被引:45
|
作者
Ricci, Ilaria [1 ]
Palermo, Michele [1 ]
Gasparini, Giada [1 ]
Silvestri, Stefano [1 ]
Trombetti, Tomaso [1 ]
机构
[1] Univ Bologna, Dept DICAM, I-40136 Bologna, Italy
关键词
Seismic behaviour; Cellular structures; Cast in situ sandwich squat concrete walls; Experimental tests; BEHAVIOR; PANELS; DESIGN; STRENGTH;
D O I
10.1016/j.engstruct.2013.03.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, the seismic behaviour of structural systems composed of squat concrete walls has been the object of a renewed interest. This paper presents the results obtained in a large experimental campaign carried out as a joint effort between the University of Bologna and the Eucentre labs in Pavia. This effort aims at the assessment of the seismic performances of cellular structures composed of cast in situ sandwich squat concrete walls. In order to shed light upon the seismic behaviour (stiffness, strength, ductility, energy-dissipation) of such structures, a number of tests were performed upon two dimensional (3.0 m by 3.0 m) cast in situ sandwich squat concrete walls (with and without openings). In the experimental tests a number of horizontal in-plane loading cycles were imposed to the specimens, while the vertical load was kept constant. The results obtained have shown that the tested elements are characterized by: (i) high values of the maximum horizontal load applied to the structural systems (higher than the applied vertical load); (ii) residual bearing capacity with respect to the vertical loads, also when large lateral deformations are imposed; and (iii) high ductility. (C) 2013 Elsevier Ltd. All rights reserved,
引用
收藏
页码:131 / 149
页数:19
相关论文
共 42 条
  • [1] Research on pseudo-static cyclic tests of precast concrete shear walls with vertical rebar lapping in grout-filled constrained hole
    Gu, Qian
    Dong, Ge
    Wang, Xiang
    Jiang, Hongbin
    Peng, Shaomin
    ENGINEERING STRUCTURES, 2019, 189 : 396 - 410
  • [2] Pseudo-Static Experiment Study on Recycled Concrete High Shear Walls
    Chen, Lihua
    Zhou, An
    Liu, Bingkang
    NOVEL AND NON-CONVENTIONAL MATERIALS AND TECHNOLOGIES FOR SUSTAINABILITY, 2012, 517 : 577 - 582
  • [3] Cyclic lateral load behavior of squat reinforced concrete walls
    Terzioglu, Tevfik
    Orakcal, Kutay
    Massone, Leonardo M.
    ENGINEERING STRUCTURES, 2018, 160 : 147 - 160
  • [4] Pseudo-static experimental study on insulated sandwich concrete wall with embedded columns
    Qiao, Wentao
    Yuan, Jiawei
    Wang, Dong
    Yin, Xiaoxiang
    Meng, Lijun
    JOURNAL OF BUILDING ENGINEERING, 2021, 34
  • [5] Experimental study on the in-plane response of cast-in-situ reinforced concrete sandwich walls under combined vertical and horizontal load
    Cassese, Paolino
    Riascos, Carlos
    Rainieri, Carlo
    De Luca, Giuseppina
    Pavese, Alberto
    Bonati, A.
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 774 - 781
  • [6] Energy-based horizontal slice method for pseudo-static analysis of reinforced walls
    Sarbishei, S.
    Fakher, A.
    GEOSYNTHETICS INTERNATIONAL, 2012, 19 (05) : 370 - 384
  • [7] Analysis of residual displacement for reinforced concrete piers under pseudo-static load
    Wang, Junwen
    Li, Haiyang
    Li, Jianzhong
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (09): : 95 - 99
  • [8] Quasi-static tests of squat reinforced concrete shear walls with openings
    Xu, Guoshan
    Zheng, Lichang
    Zhou, Wei
    Zhai, Changhai
    Wang, Dongmei
    ENGINEERING STRUCTURES, 2023, 293
  • [9] Static cyclic tests on lightly reinforced concrete shear walls
    Greifenhagen, C
    Lestuzzi, P
    ENGINEERING STRUCTURES, 2005, 27 (11) : 1703 - 1712
  • [10] Pseudo-static cyclic loading comparison of reinforced masonry walls strengthened with FRCM or NSM FRP
    Al-Jaberi, Zuhair
    Myers, John J.
    EIGawady, Mohamed A.
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 167 : 482 - 495