Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans

被引:17
|
作者
Vernekohl, Don [1 ]
Ahmad, Moiz [2 ]
Chinn, Garry [2 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 24期
关键词
XFCT; FXCT; molecular imaging; Compton camera; Compton imaging; x-ray fluorescence; gold nanoparticles; DETECTOR; SENSITIVITY; SIMULATION;
D O I
10.1088/0031-9155/61/24/8521
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray fluorescence imaging is a promising imaging technique able to depict the spatial distributions of low amounts of molecular agents in vivo. Currently, the translation of the technique to preclinical and clinical applications is hindered by long scanning times as objects are scanned with flux-limited narrow pencil beams. The study presents a novel imaging approach combining x-ray fluorescence imaging with Compton imaging. Compton cameras leverage the imaging performance of XFCT and abolish the need for pencil beam excitation. The study examines the potential of this new imaging approach on the base of Monte-Carlo simulations. In the work, it is first presented that the particular option of slice/fan-beam x-ray excitation has advantages in image reconstruction in regard of processing time and image quality compared to traditional volumetric Compton imaging. In a second experiment, the feasibility of the approach for clinical applications with tracer agents made from gold nano-particles is examined in a simulated lung scan scenario. The high energy of characteristic x-ray photons from gold is advantageous for deep tissue penetration and has lower angular blurring in the Compton camera. It is found that Doppler broadening in the first detector stage of the Compton camera adds the largest contribution on the angular blurring; physically limiting the spatial resolution. Following the analysis of the results from the spatial resolution test, resolutions in the order of one centimeter are achievable with the approach in the center of the lung. The concept of Compton imaging allows one to distinguish to some extent between scattered photons and x-ray fluorescent photons based on their difference in emission position. The results predict that molecular sensitivities down to 240 pM l(-1) for 5 mm diameter lesions at 15 mGy for 50 nm diameter gold nano-particles are achievable. A 45-fold speed up time for data acquisition compared to traditional pencil beam XFCT could be achieved for lung imaging at the cost of a small sensitivity decrease.
引用
收藏
页码:8521 / 8540
页数:20
相关论文
共 50 条
  • [1] X-ray Fluorescence Computed Tomography with a Compton Camera for a Clinical Application
    Vernekohl, Don
    Ahmad, Moiz
    Chinn, Garry
    Xing, Lei
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [2] Towards Zero Compton Background in X-ray Fluorescence Computed Tomography (XFCT)
    Nie, Xingchen
    Chen, Yunlai
    Meng, Ling-Jian
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [3] Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
    ZhiJun Chi
    HongZe Zhang
    Jin Lin
    XuanQi Zhang
    Hao Ding
    QiLi Tian
    Zhi Zhang
    YingChao Du
    WenHui Huang
    ChuanXiang Tang
    [J]. Nuclear Science and Techniques., 2024, 35 (10) - 85
  • [4] Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
    Chi, Zhi-Jun
    Zhang, Hong-Ze
    Lin, Jin
    Zhang, Xuan-Qi
    Ding, Hao
    Tian, Qi-Li
    Zhang, Zhi
    Du, Ying-Chao
    Huang, Wen-Hui
    Tang, Chuan-Xiang
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (10)
  • [5] Reduction of Compton Background Noise for X-ray Fluorescence Computed Tomography with Deep Learning
    Feng, Peng
    Luo, Yan
    Zhao, Ruge
    Huang, Pan
    Li, Yonghui
    He, Peng
    Tang, Bin
    Zhao, Xiansheng
    [J]. PHOTONICS, 2022, 9 (02)
  • [6] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    [J]. MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [7] Accelerating X-ray Fluorescence Computed Tomography
    La Riviere, P. J.
    Vargas, P.
    Fu, G.
    Meng, L. J.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1000 - +
  • [8] Cone beam x-ray luminescence computed tomography: A feasibility study
    Chen, Dongmei
    Zhu, Shouping
    Yi, Huangjian
    Zhang, Xianghan
    Chen, Duofang
    Liang, Jimin
    Tian, Jie
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [9] Feasibility study of x-ray diffraction computed tomography for medical imaging
    Kleuker, U
    Suortti, P
    Weyrich, W
    Spanne, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2911 - 2923
  • [10] A numismatic study of Roman coins through X-ray fluorescence and X-ray computed μ-tomography analysis
    Smeriglio, Andrea
    Filosa, Raffaele
    Crocco, Maria Caterina
    Formoso, Vincenzo
    Barberi, Riccardo Cristoforo
    Solano, Andrea
    Cerzoso, Maria
    Polosa, Annalisa
    Cerrone, Valerio
    Agostino, Raffaele Giuseppe
    [J]. ACTA IMEKO, 2023, 12 (04):