Effect of ischemic preconditioning on rat liver microcirculation monitored with laser Doppler flowmetry

被引:39
|
作者
Szijártó, A
Hahn, O
Lotz, G
Schaff, Z
Madarász, E
Kupcsulik, PK
机构
[1] Semmelweis Univ, Dept Surg, H-1082 Budapest, Hungary
[2] Semmelweis Univ, Dept Pathol, H-1082 Budapest, Hungary
[3] Hungarian Acad Sci, Inst Expt Med, Budapest, Hungary
关键词
ischemia; reperfusion; preconditioning; liver; laser Doppler flowmeter;
D O I
10.1016/j.jss.2005.09.002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Ischemic preconditioning (IP) may protect the liver from ischemia-reperfusion (I-R) injury during liver resection. This study investigated the effect of IP on hepatic microcirculation. (HM) and analyzed the objective parameters of the EM using laser Doppler flowmetry (LDF). Methods. We used male Wistar rats (250-280 g) that underwent normothermic, segmental liver ischemia. The animals were divided into eight groups: 30, 45, 60, and 90 min of ischemia with, or without, IP. Five minutes ischemia and 10 min reperfusion, in two cycles, were used to elicit IP. Changes of the hepatic microcirculation were studied by LDF with on-line computer monitoring and processing. Histological alterations, liver enzymes, bilirubin, and TNF-alpha level were all measured simultaneously. Results. Reperfusion was assessed by post-ischemia flux plateau maximum (PM) and by the area under the reperfusion-curve (RA). Both PM and RA are inversely correlated with the duration of ischemia. The groups with H? had significantly (P < 0.05) higher flow values than groups without preconditioning. IP before liver ischemia resulted in significantly (P < 0.05) lower TNF-a levels at the end of the 30-min reperfusion. Lower serum ALT, LDH, and bilirubin levels could only be observed at 45 and 60 min I-R during the first post-operative day. On the seventh post-operative day there were no significant differences between the I-R and IP + IR groups in any of these parameters. Conclusion. The benefit of ischemic preconditioning on hepatic microcirculation was well demonstrated with this method, which has never been described before, in this context. Changes in hepatic microcirculation can be precisely investigated by laser Doppler flowmetry using the standardization and transformation described in this paper. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:150 / 157
页数:8
相关论文
共 50 条
  • [1] DIAPHRAGMATIC MICROCIRCULATION MEASURED BY LASER-DOPPLER FLOWMETRY IN THE RAT
    CHANG, HY
    CHEN, CR
    HUSSAIN, SNA
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (04) : 1225 - 1233
  • [2] THE EFFECT OF PRAZOSIN ON SKIN MICROCIRCULATION AS ASSESSED BY LASER DOPPLER FLOWMETRY
    KHAN, F
    STRUTHERS, AD
    SPENCE, VA
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 26 (03) : 267 - 272
  • [3] VASOMOTION IN THE RAT CEREBRAL MICROCIRCULATION RECORDED BY LASER-DOPPLER FLOWMETRY
    MORITATSUZUKI, Y
    BOUSKELA, E
    HARDEBO, JE
    ACTA PHYSIOLOGICA SCANDINAVICA, 1992, 146 (04): : 431 - 439
  • [4] Laser Doppler flowmetry to assess myocardial microcirculation
    Piotrowski, Jakub
    Anisimowicz, Lech
    Hellmann, Marcin
    CARDIOLOGY JOURNAL, 2020, 27 (02) : 197 - 199
  • [5] LASER DOPPLER FLOWMETRY FOR THE ASSESSMENT OF THE CEREBRAL MICROCIRCULATION
    ELLIS, EF
    HEIZER, ML
    ZHANG, X
    MARMAROU, A
    HABERL, R
    FASEB JOURNAL, 1988, 2 (04): : A507 - A507
  • [6] Effect of ischemic preconditioning on spinal cord blood flow in a rat model of spinal cord ischemia when measured by laser Doppler flowmetry
    Deal, DD
    Colonna, DM
    Zvara, DA
    Vernon, JC
    Gowda, M
    ANESTHESIA AND ANALGESIA, 1999, 88 (04):
  • [7] LASER DOPPLER FLOWMETRY - MUSCULAR MICROCIRCULATION IN ANESTHESTIZED HORSES
    SERTEYN, D
    MOTTART, E
    MICHAUX, C
    MICHEELS, J
    PHILIPPART, C
    LAVERGNE, L
    GUILLON, C
    LAMY, M
    EQUINE VETERINARY JOURNAL, 1986, 18 (05) : 391 - 395
  • [8] Effect of Photoperiod Duration on Microcirculation in the Skin as Assessed Experimentally by Laser Doppler Flowmetry
    O. V. Zlobina
    S. S. Pakhomii
    E. V. Smolina
    T. V. Milashevskaya
    A. A Dolgov
    A. I. Ivanov
    I. O. Bugaeva
    Optics and Spectroscopy, 2021, 129 : 857 - 860
  • [9] MICROCIRCULATION OF THE SMALL-INTESTINE AND SKIN IN THE RAT MEASURED BY LASER DOPPLER FLOWMETRY AND MICROSPHERES
    ENOCHSSON, L
    WAHLBERG, E
    OHMAN, U
    GASTROENTEROLOGY, 1987, 92 (05) : 1383 - 1383
  • [10] Effect of Photoperiod Duration on Microcirculation in the Skin as Assessed Experimentally by Laser Doppler Flowmetry
    Zlobina, O., V
    Pakhomii, S. S.
    Smolina, E., V
    Milashevskaya, T., V
    Dolgov, A. A.
    Ivanov, A. I.
    Bugaeva, I. O.
    OPTICS AND SPECTROSCOPY, 2021, 129 (08) : 857 - 860