摘要
The Utah Department of Transportation has recently developed the Signal Performance Metrics System (SPMS) to evaluate the performance of signalized intersections dynamically. This system currently provides data summaries for several performance measures, one of them being turning movement volume counts. As this system became public, there was a need to evaluate the accuracy of the data collected by microwave sensors for the SPMS. UDOT considered first that sensor position, number of approach lanes, and volume level would affect the accuracy. Later, speed limit was added as another factor. Data were collected manually and compared with volume count data reported by the system. A Mixed Model Analysis of Variance was employed to analyze the effect of each factor on the accuracy of traffic volume counts. The volume level and number of approach lanes factors were found to have a statistically significant effect on the accuracy of traffic volume counts by microwave sensors.
引用
收藏
页码:945 / 956
页数:12
相关论文
共 41 条
  • [1] Use of Hi-resolution data for evaluating accuracy of traffic volume counts collected by microwave sensors
    David K.Chang
    Mitsuru Saito
    Grant G.Schultz
    Dennis L.Eggett
    Journal of Traffic and Transportation Engineering(English Edition), 2017, 4 (05) : 423 - 435
  • [2] HOW ACCURATE ARE THE PERFORMANCE DATA COLLECTED BY THE BCSS?
    Brooklyn, T.
    Boyle, S.
    Brooklyn, S.
    Mulrenan, M.
    Quance, C.
    Dowler, K.
    Anderson, J.
    GUT, 2009, 58 : A56 - A56
  • [4] How accurate are measurements with piezoresistive sensors?
    Gerlach, G
    Sager, K
    Nakladal, A
    TECHNISCHES MESSEN, 1996, 63 (11): : 403 - 412
  • [5] How accurate is a TRUS prostate volume?
    Hong, M. K. H.
    Corcoran, N. M.
    Rzetelski-West, K.
    Namdarian, B.
    Peters, J. S.
    Hovens, C. M.
    BJU INTERNATIONAL, 2010, 105 : 19 - 19
  • [6] Loss Tangent Effect on the Accurate Design of Microwave Sensors for Blood Glucose Monitoring
    Costanzo, Sandra
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017, : 661 - 663
  • [7] Non-Destructive Volume and Thickness Measurements with Planar Microwave Sensors
    Al Jader, M.
    Korostynska, O.
    Mason, A.
    Al-Shamma'a, A. I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 465 - 468
  • [8] Prediction Aggregation of Remote Traffic Microwave Sensors Speed and Volume Data
    Junger, John R.
    Havlicek, Joseph P.
    Barnes, Ronald D.
    Tull, Monte P.
    2009 12TH INTERNATIONAL IEEE CONFERENCE ON INTELLIGENT TRANSPORTATION SYSTEMS (ITSC 2009), 2009, : 672 - 678
  • [9] How accurate is in-patient smoking status data collected by hospital admissions staff?
    Schofield, PE
    Hill, DJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF PUBLIC HEALTH, 1999, 23 (06) : 654 - 656
  • [10] How Accurate Is Multiparametric MR Imaging in Evaluation of Prostate Cancer Volume?
    Bratan, Flavie
    Melodelima, Christelle
    Souchon, Remi
    Au Hoang Dinh
    Mege-Lechevallier, Florence
    Crouzet, Sebastien
    Colombel, Marc
    Gelet, Albert
    Rouviere, Olivier
    RADIOLOGY, 2015, 275 (01) : 144 - 154