Malignant pleural mesothelioma: US-guided histologic core-needle biopsy

被引:58
|
作者
Heilo, A
Stenwig, AE
Solheim, OP
机构
[1] Norwegian Radium Hosp, Dept Radiol, N-0310 Oslo, Norway
[2] Norwegian Radium Hosp, Dept Pathol, N-0310 Oslo, Norway
[3] Norwegian Radium Hosp, Dept Oncol, N-0310 Oslo, Norway
关键词
biopsies; technology; mesothelioma; pleura; biopsy; neoplasms; ultrasound; (US); guidance;
D O I
10.1148/radiology.211.3.r99jn03657
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the clinical use of ultrasonographically (US) guided core-needle biopsy, performed with a one-hand automatic sampling technique, in the diagnosis of malignant pleural mesothelioma (MPM). MATERIALS AND METHODS: The authors reviewed the findings in 70 patients with a tentative diagnosis of MPM who underwent US-guided core-needle biopsy at our institution during the past 10 years. RESULTS: Fifty-two of the 70 patients who underwent automatic high-speed core-needle biopsy at our institution had MPM; 18 had other disorders. The correct diagnosis was made in 56 patients. Twelve of 14 inadequate biopsy specimens were false-negative for MPM. There were no false-positive biopsy results. In the detection of MPM, US-guided core-needle biopsy had a sensitivity of 77%, specificity of 88%, accuracy of 80% positive predictive value of 100%, and negative predictive value of 57%. There were no serious complications. CONCLUSION: US-guided core-needle biopsy is highly effective in the diagnosis of MPM. Owing to its simplicity, low cost, and few side effects, it could be the biopsy method of choice for detection of this condition.
引用
收藏
页码:657 / 659
页数:3
相关论文
共 50 条
  • [1] TUMORS IN THE MEDIASTINUM - US-GUIDED HISTOLOGIC CORE-NEEDLE BIOPSY
    HEILO, A
    RADIOLOGY, 1993, 189 (01) : 143 - 146
  • [2] US-guided core-needle biopsy of the thyroid gland
    Screaton, NJ
    Berman, LH
    Grant, JW
    RADIOLOGY, 2003, 226 (03) : 827 - 832
  • [3] Liver hemangioma: US-guided core-needle biopsy - Response
    Heilo, A
    RADIOLOGY, 1998, 208 (01) : 267 - 268
  • [4] US-guided core-needle biopsy of the breast: Technique and pitfalls
    Ciambotti, JM
    Harvey, JA
    Moran, RE
    RADIOLOGY, 1996, 201 : 25 - 25
  • [5] US-guided core-needle biopsy of the breast: How many specimens are necessary
    Fishman, JE
    Milikowski, C
    Ramsinghani, R
    Velasquez, MV
    Aviram, G
    RADIOLOGY, 2003, 226 (03) : 779 - 782
  • [6] Liver hemangioma: US-guided 18-gauge core-needle biopsy
    Heilo, A
    Stenwig, AE
    RADIOLOGY, 1997, 204 (03) : 719 - 722
  • [7] Effectiveness of core-needle US-guided biopsy as a primary tool for diagnosis of thyroid nodules
    Ali, Reda F.
    Eldwowik, Yasser M.
    Aouf, Ahmed
    Hegab, Sherif
    Abouelnagah, Galal M.
    EGYPTIAN JOURNAL OF SURGERY, 2021, 40 (03): : 795 - 799
  • [8] Evaluation of a turkey-breast phantom for teaching freehand, US-guided core-needle breast biopsy
    Harvey, JA
    Moran, RE
    Hamer, MM
    DeAngelis, GA
    Omary, RA
    ACADEMIC RADIOLOGY, 1997, 4 (08) : 565 - 569
  • [9] US-guided core needle biopsy of the breast: Technique and pitfalls
    Harvey, JA
    Moran, RE
    RADIOGRAPHICS, 1998, 18 (04) : 867 - 877
  • [10] US-guided 14-gauge core-needle breast biopsy: Results of a validation study in 1352 cases
    Schueller, Gerd
    Jaromi, Sylvia
    Ponhold, Lothar
    Fuchsjaeger, Michael
    Memarsadeghi, Mazda
    Rudas, Margaretha
    Weber, Michael
    Liberman, Laura
    Helbich, Thomas H.
    RADIOLOGY, 2008, 248 (02) : 406 - 413