Bioelectrical impedance analysis before versus after a hemodialysis session in evaluation of nutritional status

被引:12
|
作者
Jankowska, M [1 ]
Debska-Slizien, A [1 ]
Rutkowski, B [1 ]
机构
[1] Med Univ Gdansk, Dept Nephrol Transplantol & Internal Med, Gdansk, Poland
关键词
D O I
10.1053/j.jrn.2006.01.005
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: The objective of our study was to evaluate whether bioelectrical impedance analysis (BIA) performed 15 minutes after a hemodialysis (HID) session is clinically useful in nutrition status assessment in comparison with BIA performed before HID. Because of better reliability, it is postulated in the literature that BIA measurements should be performed 1 to 5 hours after HID sessions. However, the measurements 1 to 5 hours after HID sessions are inconvenient in clinical practice. Furthermore, the currently published BIA reference values for the HID population are based on the measurements taken before HID sessions. Methods: The study group consisted of 29 HID patients who were in a stable clinical condition. BIA measurements were performed by means of BIA 101 System (Akern RJL Systems, Florence, Italy). The correlation coefficients were surveyed between traditional indices of nutritional status, such as body mass index (BMI) and plasma concentrations of protein, albumin, and nonprotein nitrogen blood urea nitrogen (BUN) (measured before HID) on one hand, and BIA parameters (taken before and 15 minutes after HID) on the other hand. Results: Statistically significant correlations occurred between such BIA parameters as (1) phase angle and BMI or albumin, or total protein or BUN and (2) body cell mass and BMI or BUN. The differences between correlation coefficients achieved either before or after HID were statistically nonsignificant. Conclusions: BIA measurements in the studied group of patients did correlate with traditional indices of nutritional status. The correlation coefficients were not significantly influenced by the time of performing BIA measurements. The obtained correlations confirm that BIA performed 15 minutes after an HID session may be a useful tool in evaluation of nutritional status of stable HID patients in clinical practice. (c) 2006 by the National Kidney Foundation, Inc.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 50 条
  • [1] A systematic evaluation of bioelectrical impedance measurement after hemodialysis session
    Di Iorio, BR
    Scalfi, L
    Terracciano, V
    Bellizzi, V
    KIDNEY INTERNATIONAL, 2004, 65 (06) : 2435 - 2440
  • [2] Reliability of Bioelectrical Impedance Analysis in the Evaluation of the Nutritional Status of Hemodialysis Patients - A Comparison With Mini Nutritional Assessment
    Erdogan, E.
    Tutal, E.
    Uyar, M. E.
    Bal, Z.
    Demirci, B. G.
    Sayin, B.
    Sezer, S.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (10) : 3485 - 3488
  • [3] USEFULNESS OF BIOELECTRICAL IMPEDANCE ANALYSIS FOR ASSESSING NUTRITIONAL STATUS IN HEMODIALYSIS PATIENTS
    Lee, Jung Eun
    Yun, Gi Young
    Choi, Hoon Young
    Lee, Songmi
    Kim, Woojeong
    Jo, In Young
    Ha, Sung Kyu
    Kim, Hyung Jong
    Park, Hyeong Cheon
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 292 - 293
  • [4] Bioelectrical impedance analysis and nutritional assessment in hemodialysis
    Oliveira, Claudia M. C.
    Kubrusly, Marcos
    Mota, Rosa S.
    Vasconcelos, Paulo R. L.
    Choukroun, Gabriel
    Oliveira, Valzimeire N.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 454 - 454
  • [5] Bioelectrical impedance analysis in the evaluation of the nutritional status of continuous ambulatory peritoneal dialysis patients
    Passadakis, P
    Sud, K
    Dutta, A
    Singhal, M
    Pettit, J
    Chatalalsingh, C
    Thodis, E
    Vargemezis, V
    Oreopoulos, D
    ADVANCES IN PERITONEAL DIALYSIS/1999, VOL 15, 1999, 15 : 147 - 152
  • [6] Evaluation of nutritional status using bioelectrical impedance analysis in patients with inflammatory bowel disease
    Kim, Seung Hyuk
    Kim, You Sun
    Lee, Si Hyeong
    Lee, Hyun Mi
    Yoon, Won Eui
    Kim, Seo Hyun
    Myung, Hee Jun
    Moon, Jeong Seop
    INTESTINAL RESEARCH, 2022, 20 (03) : 321 - 328
  • [7] Bioelectrical impedance analysis before and after Novacor implantation
    Stellato, D
    Cirillo, M
    De Santo, LS
    Maiello, C
    Marra, C
    de Vivo, F
    Anastasio, P
    Di Iorio, B
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (03): : 151 - 154
  • [8] Evaluation of Electrocardiographic Findings before and after Hemodialysis Session
    Jebali, Hela
    Ghabi, Hiba
    Mami, Ikram
    Ben Fatma, Lilia
    Smaoui, Wided
    Ben Kaab, Badr
    Krid, Madiha
    Ben Hlima, Manel
    Ben Ayed, Tasnim
    Guermazi, Omar
    Mourali, Mohamed Sami
    Beji, Soumaya
    Chermiti, Mohamed
    Zied, Loumi
    Kateb, Hanene
    Hassan, Mohanad
    Ben Hmida, Fethi
    Raies, Lamia
    Zouaghi, Mohamed Karim
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2020, 31 (03) : 639 - 646
  • [9] NUTRITIONAL ASSESSMENT WITH BIOELECTRICAL-IMPEDANCE ANALYSIS IN MAINTENANCE HEMODIALYSIS-PATIENTS
    CHERTOW, GM
    LOWRIE, EG
    WILMORE, DW
    GONZALEZ, J
    LEW, NL
    LING, J
    LEBOFF, MS
    GOTTLIEB, MN
    HUANG, W
    ZEBROWSKI, B
    COLLEGE, J
    LAZARUS, JM
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (01): : 75 - 81
  • [10] Bioelectrical impedance analysis as a marker of nutritional status in chronically ill patients
    Krel, Cvetka
    Piko, Nejc
    Tomazic, Jozica
    Bevc, Sebastjan
    AUSTRALIAN JOURNAL OF ADVANCED NURSING, 2019, 36 (03) : 14 - 21