Effects of Blade Discharge Angle, Blade Number and Splitter Blade Length on Deep Well Pump Performance

被引:19
|
作者
Korkmaz, E. [1 ]
Golcu, M. [2 ]
Kurbanoglu, C. [3 ]
机构
[1] Suleyman Demirel Univ, Energy Syst Engn Dept, TR-32260 Isparta, Turkey
[2] Pamukkale Univ, Automot Engn Dept, TR-20017 Kinikli, Denizli, Turkey
[3] Istanbul Medeniyet Univ, Dept Mech Engn, TR-34730 Istanbul, Turkey
关键词
Deep well pump; Blade discharge angle; Pump performance; Impeller; Splitter blade; ENERGY;
D O I
10.18869/acadpub.jafm.73.238.26056
中图分类号
O414.1 [热力学];
学科分类号
摘要
Impellers with splitter blades are used for pumps and compressors in the design of turbomachines. Design parameters such as the number of blades, blade discharge angle and impeller discharge diameter impact affect pump performance and energy consumption. In this study, the effect of the number of blades (z=5, 6, and 7), blade discharge angles (beta(2b)=25 degrees, and beta(2b)=35 degrees) and splitter blade lengths (40, 55, 70, and 85% of the main blade length) on Deep Well Pump (DWP) performance has been studied experimentally. In the experiments, pump casing, blade inlet angle, blade thickness, blade width and impeller inlet and discharge diameters have been kept fixed while other parameters such as the number of blades, blade discharge angles and splitter blade lengths have been allowed to vary. As a result of the experimental study, the highest efficiency of all the impellers for best efficiency point (b.e.p) has been obtained on the impeller with the number of blades z=6, blade discharge angle beta(2b)=25 degrees and 85% splitter blade addition compared to impellers without splitter blades.
引用
收藏
页码:529 / 540
页数:12
相关论文
共 50 条
  • [1] Energy saving in a deep well pump with splitter blade
    Gölcü, M
    Pancar, Y
    Sekmen, Y
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (05) : 638 - 651
  • [2] Effects of the Splitter Blade on the Performance of a Pump-Turbine in Pump Mode
    Li, Guidong
    Wang, Yang
    Cao, Puyu
    Zhang, Jinfeng
    Mao, Jieyun
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [3] Effect of splitter blade on the performance of pump as turbine
    Yang, Sunsheng
    Kong, Fanyu
    Xue, Ling
    Hu, Li
    [J]. Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2012, 43 (07): : 104 - 107
  • [4] Influence of blade inlet angle on the performance of a single blade centrifugal pump
    Chen, Jianfang
    Shi, Weidong
    Zhang, Desheng
    [J]. ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2021, 15 (01) : 462 - 475
  • [5] Analysis effects of blade angle on centrifugal pump performance
    Pan, Zhongyong
    Xie, Rong
    Cao, Yingjie
    Li, Xiaojun
    [J]. Paiguan Jixie/Drainage and Irrigation Machinery, 2009, 27 (05): : 319 - 322
  • [6] Effects of Blade Number on the Centrifugal Pump Performance: A Review
    Sakran, Hayder Kareem
    Aziz, Mohd Sharizal Abdul
    Abdullah, M. Z.
    Khor, C. Y.
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (07) : 7945 - 7961
  • [7] Effects of Blade Number on the Centrifugal Pump Performance: A Review
    Hayder Kareem Sakran
    Mohd Sharizal Abdul Aziz
    M. Z. Abdullah
    C. Y. Khor
    [J]. Arabian Journal for Science and Engineering, 2022, 47 : 7945 - 7961
  • [8] Investigation of performance characteristics in a pump impeller with low blade discharge angle
    Gölcü, Mustafa
    Pancar, Yas¸ar
    [J]. World Pumps, 2005, (468) : 32 - 40
  • [9] Research on effects of blade wrap angle on the centrifugal pump performance
    Ge, Shuting
    Song, Wenwu
    [J]. ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 2197 - 2200
  • [10] Centrifugal pump performance enhancement: Effect of splitter blade and optimization
    Siddique, Mohammed Hamid
    Samad, Abdus
    Hossain, Shakhawat
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (02) : 391 - 402