Use of the retrograde ''pull-through'' technique for aortic redissection and aneurysm of the false lumen

被引:0
|
作者
Vitali, E [1 ]
Colucci, V [1 ]
Fedriga, E [1 ]
机构
[1] OSPED NIGUARDA CA GRANDA,A DE GASPERIS CARDIAC SURG DEPT,I-20162 MILAN,ITALY
关键词
aorta; thoracic; surgery; aortic aneurysm; aneurysm; dissecting;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 50-year-old man, who 9 months earlier had undergone emergency operation for acute type I aortic dissection, was readmitted to our hospital with the diagnosis of an enlarging aneurysm of the false lumen involving the transverse arch and the proximal third of the descending thoracic aorta, due principally to redissection at the distal suture line of the ascending aortic graft. Replacement of the aortic arch and proximal descending thoracic aorta was performed by using the retrograde ''pull-through'' technique with hypothermic circulatory arrest and retrograde cerebral perfusion. Although circulatory arrest lasted 110 minutes, the patient was extubated on the 2nd postoperative day and had no central or peripheral neurologic damage. Mild, transitory renal dysfunction was observed in the Ist postoperative week, and the patient was discharged on the 18th postoperative day. He is asymtomatic at 15 postoperative months. Deep hypothermia and retrograde cerebral perfusion proved effective despite prolonged circulatory arrest. The retrograde ''pull-through'' technique is an effective method of replacing the entire thoracic aorta and should probably be considered for single-stage repair of acute type I aortic dissection with multiple intimal tears.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 50 条
  • [1] Novel Technique for Ablation of Persistent Retrograde Perfusion of False Lumen in Chronic Aortic Dissection
    Rodriguez, April L.
    Starnes, Benjamin W.
    Singh, Niten
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 231S - 231S
  • [2] A PULL-THROUGH TECHNIQUE FOR RECTAL RESECTION
    BARNES, JP
    [J]. SURGERY GYNECOLOGY AND OBSTETRICS WITH INTERNATIONAL ABSTRACTS OF SURGERY, 1966, 123 (02): : 357 - &
  • [3] A NEW TECHNIQUE FOR GASTRIC PULL-THROUGH
    SHRIVER, CD
    SPIRO, RH
    BURT, M
    [J]. SURGERY GYNECOLOGY & OBSTETRICS, 1993, 177 (05): : 519 - 520
  • [4] Endovascular Retrograde Reconstruction of the Left Renal Artery through the False Lumen of a Postdissection Thoracoabdominal Aortic Aneurysm-A Case Report
    Jia, Senhao
    Zhang, Hongpeng
    Sun, Guoyi
    Ge, Yangyang
    Wang, Lijun
    Guo, Wei
    [J]. ANNALS OF VASCULAR SURGERY, 2019, 55 : 307.e5 - 307.e11
  • [5] Endografting the True Lumen and False Lumen of an Enlarging Infrarenal Aortic Aneurysm
    Milczarek, Krzysztof
    Rosiak, Grzegorz
    Bielecki, Dennis
    Szmidt, Jacek
    Rowinski, Olgierd
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (11) : 1778 - 1779
  • [6] Combined use of ultrasonic liposuction with the pull-through technique for the treatment of gynecomastia
    Rohrich, RJ
    Ha, RY
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 112 (03) : 896 - 897
  • [7] Inducing false lumen thrombosis for retrograde type A aortic dissection
    Zhang, Rongjie
    Zhou, Jian
    Feng, Jiaxuan
    Zhao, Zhiqing
    Liu, Junjun
    Li, Zhenjiang
    Feng, Rui
    Jing, Zaiping
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01): : 57 - 65
  • [8] PULL-THROUGH BRANCHIAL FISTULECTOMY - A TECHNIQUE FOR THE OTOLARYNGOLOGIST
    TALAAT, M
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1992, 101 (06): : 501 - 502
  • [9] Anorectal pull-through and vector volume manometry - Comparison of station and continuous pull-through technique.
    Pietsch, AP
    Obermaier, R
    Mahowiec, F
    Hopt, UT
    [J]. GASTROENTEROLOGY, 2000, 118 (04) : A1526 - A1526
  • [10] PULL-THROUGH TECHNIQUE COMBINED WITH LIPOSUCTION IN GYNECOMASTIA
    Karamese, Mehtap
    Keskin, Mustafa
    Sutcu, Mustafa
    Akdag, Osman
    Tosun, Zekeriya
    Savaci, Nedim
    [J]. TURKISH JOURNAL OF PLASTIC SURGERY, 2011, 19 (02): : 78 - 81