Inter-fraction motion and dosimetric consequences during breast intensity-modulated radiotherapy (IMRT)

被引:50
|
作者
Jain, Popja [1 ]
Marchant, Tom [4 ]
Green, Melanie [1 ]
Watkins, Gillian [1 ]
Davies, Julie [3 ]
McCarthy, Claire [3 ]
Loncaster, Juliette [2 ]
Stewart, Alan [2 ]
Magee, Brian [2 ]
Moore, Christopher [4 ]
Price, Pat [1 ]
机构
[1] Univ Manchester, Acad Dept Radiat Oncol, Manchester M20 4BX, Lancs, England
[2] Christie Hosp NHS Fdn Trust, Dept Clin Oncol, Manchester M20 4BX, Lancs, England
[3] Christie Hosp NHS Fdn Trust, Wade Ctr Radiotherapy Res, Manchester M20 4BX, Lancs, England
[4] Christie Hosp NHS Fdn Trust, N Western Med Phys, Manchester M20 4BX, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Breast radiotherapy; IMRT; Cone-beam imaging; Inter-fraction motion; Dose homogeneity; BEAM COMPUTED-TOMOGRAPHY; QUALITY ASSURANCE; PATIENT MOVEMENT; IRRADIATION; CANCER; SETUP; ACCURACY; FIELDS; POSITION; WOMEN;
D O I
10.1016/j.radonc.2008.10.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Intensity-modulated radiotherapy (IMRT) can improve dose homogeneity within the breast planned target Volume (PTV), but may be more susceptible to patient/organ motion than standard tangential radiotherapy (RT). We used daily cone-beam CT (CBCT) imaging to assess inter-fraction motion during breast IMRT and its subsequent impact oil IMRT and standard RT dose homogeneity. Materials and methods: Ten breast cancer patients selected for IMRT were Studied, CBCT images were acquired immediately after daily treatment. Automatic image co-registration was used to determine patient positioning variations. Daily PTV contours were used to Calculate PTV variations and daily delivered IMRT and theoretically planned tangential RT dose. Results: Group systematic (and random) setup errors detected by CBCT were 5.7 (3.9) mm laterally, 2.8 (3.5) mm vertically and 2.3 (3,2) torn longitudinally. Rotations >2 degrees in any axis occurred oil 53/106 (50%) occasions. Daily PTV volume varied up to 23%, IMRT dose homogeneity was Superior at planning and throughout the treatment compared with standard RT (1.8% vs. 15.8% PTV received >105% planned mean close), despite increased motion sensitivity. Conclusions: CBCT revealed inadequacies of current patient positioning and verification procedures during breast RT and confirmed improved dose homogeneity using IMRT for the patients Studied. (C) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 90 (2009) 93-98
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [1] Inter-fraction prostate motion during intensity-modulated radiotherapy for prostate cancer
    Siow, T. R.
    Ngoi, C. L. F.
    Tan, W. K. T.
    [J]. SINGAPORE MEDICAL JOURNAL, 2011, 52 (06) : 405 - 409
  • [2] The clinical evaluation of inter-fraction time trends in prostate positioning during intensity-modulated radiotherapy
    Hofman, P.
    Kotte, A.
    Dehnad, H.
    Lagendijk, J.
    van Vulpen, M.
    van der Heide, U.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S196 - S197
  • [3] The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments
    Hector, CL
    Webb, S
    Evans, PM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 54 (01) : 57 - 64
  • [4] Degradation of target coverage due to inter-fraction motion during intensity-modulated proton therapy of prostate and elective targets
    Thornqvist, Sara
    Muren, Ludvig P.
    Bentzen, Lise
    Hysing, Liv B.
    Hoyer, Morten
    Grau, Cai
    Petersen, Jorgen B. B.
    [J]. ACTA ONCOLOGICA, 2013, 52 (03) : 521 - 527
  • [5] The dosimetric consequences of inter-fractional patient movement on three classes of intensity-modulated delivery techniques in breast radiotherapy
    Hector, CL
    Evans, PM
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 59 (03) : 281 - 291
  • [6] Dosimetric consequences of inter-fraction breathing-pattern variation on radiotherapy with personalized motion-assessed margins
    Kavanagh, A.
    McQuaid, D.
    Evans, P.
    Webb, S.
    Guckenberger, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7033 - 7043
  • [7] The dosimetric consequences of patient movement on three classes of intensity-modulated delivery techniques in breast radiotherapy
    Hector, CL
    Evans, PM
    Webb, S
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 289 - 291
  • [8] A Dosimetric Comparison of Inverse Intensity-modulated Radiotherapy and Forward Intensity-modulated Radiotherapy for Breast Cancer After Radical Mastectomy
    Zhang, G.
    Yin, Y.
    Lu, J.
    [J]. EUROPEAN JOURNAL OF CANCER, 2011, 47 : S341 - S342
  • [9] Dosimetric evaluation of irregular surface compensator and intensity-modulated radiotherapy in breast radiotherapy
    Inan, Gokcen
    Gul, Osman Vefa
    Basaran, Hamit
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (06) : 984 - 989
  • [10] Accelerated intensity-modulated radiotherapy to breast in prone position: Dosimetric results
    DeWyngaert, J. Keith
    Jozsef, Gabor
    Mitchell, James
    Rosenstein, Barry
    Formenti, Silvia C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1251 - 1259