Fatigue scatter of 1.2542 tool steel after deep cryogenic treatment

被引:6
|
作者
Niaki, Keyvan Seyedi [1 ]
Vandat, Seyed Ebrahim [2 ]
机构
[1] IROST, Dept Mech Engn, Tehran, Iran
[2] Islamic Azad Univ, Ayatollah Amoli Branch, Dept Engn, Amol, Iran
关键词
Reliability of design; Design of part; Fatigue scatter; MECHANICAL-PROPERTIES; TENSILE TOUGHNESS; MICROSTRUCTURE; CARBIDES; BEHAVIOR;
D O I
10.1016/j.matpr.2015.07.033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fatigue failure is the most common failure in engineering parts. Therefore, effect of deep cryogenic treatment on the fatigue strength of 1.2542 tool steel has become important. In this study, two groups of specimens were used to investigate fatigue behavior; only one of these groups underwent deep cryogenic treatment in liquid nitrogen for 4 h after hardening treatment in water. The results showed that fatigue limits of both groups were approximately the same; however, scatter of fatigue data was less in the deep cryogenic specimens. Thus, in design process, deep cryogenic specimens can be used with more reliability coefficient; therefore, dimensions of engineering parts are reduced. (C) 2014 The Authors. Elsevier Ltd. All rights reserved.
引用
收藏
页码:1210 / 1215
页数:6
相关论文
共 50 条
  • [1] Mechanism of Precipitation of Carbides during Deep Cryogenic Processing in 1.2542Tool Steel
    Vandat, Seyed Ebrahim
    Niaki, Keyvan Seyedi
    MATERIALS TODAY-PROCEEDINGS, 2015, 2 (4-5) : 1859 - 1867
  • [2] Fatigue scatter reduction through deep cryogenic treatment on the 18NiCrMo5 carburized steel
    Baldissera, Paolo
    MATERIALS & DESIGN, 2009, 30 (09) : 3636 - 3642
  • [3] Study of effects of deep cryotreatment on mechanical properties of 1.2542 tool steel
    Farhani, Foad
    Niaki, Keyvan Seyedi
    Vahdat, Seyed Ebrahim
    Firozi, Amir
    MATERIALS & DESIGN, 2012, 42 : 279 - 288
  • [4] Effect of microstructure parameters on tensile toughness of tool steel after deep cryogenic treatment
    Seyed Ebrahim Vahdat
    Said Nategh
    Shamsoddin Mirdamadi
    International Journal of Precision Engineering and Manufacturing, 2014, 15 : 497 - 502
  • [5] Effect of Microstructure Parameters on Tensile Toughness of Tool Steel after Deep Cryogenic Treatment
    Vahdat, Seyed Ebrahim
    Nategh, Said
    Mirdamadi, Shamsoddin
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (03) : 497 - 502
  • [6] Cryogenic treatment deep cryogenic treatment of a D2 cold work tool steel
    Collins, D.N.
    Dormer, J.
    International Heat Treatment and Surface Engineering, 2008, 2 (3-4) : 150 - 154
  • [7] Microstructure and tensile properties of 45WCrV7 tool steel after deep cryogenic treatment
    Vahdat, Seyed Ebrahim
    Nategh, Saeed
    Mirdamadi, Shamsoddin
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2013, 585 : 444 - 454
  • [8] Cryogenic treatment deep cryogenic treatment of tool steels: A review
    Collins, D.N.
    International Heat Treatment and Surface Engineering, 2008, 2 (3-4) : 147 - 149
  • [9] On the Optimization of Microstructure and Mechanical Properties of CrWMn Tool Steel by Deep Cryogenic Treatment
    Wang, Kaikai
    Gu, Kaixuan
    Misra, R. D. K.
    Chen, Liubiao
    Liu, Xuanzhi
    Weng, Zeju
    Wang, Junjie
    STEEL RESEARCH INTERNATIONAL, 2019, 90 (05)
  • [10] Effect of Deep Cryogenic Treatment on Wear Behavior of Cold Work Tool Steel
    Essam, Mahmoud A.
    Shash, Ahmed Y.
    El-Fawakhry, Mohamed Kamal
    El-Kashif, Emad
    Megahed, Hassan
    METALS, 2023, 13 (02)