Direct Detection of Amino Acids Using Extractive Electrospray Ionization Tandem Mass Spectrometry

被引:18
|
作者
Xu Ning [1 ]
Zhu Zhi-Qiang [1 ]
Yang Shui-Ping [1 ]
Wang Jiang [1 ]
Gu Hai-Wei [1 ]
Zhou Zhen [2 ,3 ]
Chen Huan-Wen [1 ]
机构
[1] E China Inst Technol, Jiangxi Key Lab Mass Spectrometry & Instrumentat, Nanchang 330013, Peoples R China
[2] Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200444, Peoples R China
[3] Guangzhou Hexin Analyt Instrumentat Co, Guangzhou 510530, Guangdong, Peoples R China
关键词
Extractive electrospray ionization; Ambient mass spectrometry; Amino acids; Urine; CAPILLARY-ELECTROPHORESIS; MS/MS ANALYSIS; BODY-FLUIDS; METABOLISM; DIAGNOSIS; TOOL; MS;
D O I
10.3724/SP.J.1096.2013.20952
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method, based on extractive electrospray ionization (EESI) tandem mass spectrometry (MS), was developed for the direct detection of amino acids in biological fluids with minimal sample pretreatment. Based on our previous research, we constructed a new EESI ion source to improve the analytical performance and operation safety. We optimized EESI-MS conditions using representative amino acid standards. The reagent solvent (methanol :water=1:1) was electrosprayed at 5 mu L/min at high voltage (+4 kV, positive ion detection mode). The temperature of the heated capillary was optimized to be 150 degrees C. Collision induced dissociation (CID) experiments were done by applying 17%-25% of the collision energy to the precursor ions isolated with a window width of 1. 5 mass/charge (m/z) units. The limit of detection (LOD) of these amino acids was in the range of 0. 14 -26. 2 mu g/L, and the linear dynamic range was larger than two orders of magnitude. The amino acid concentration in human urine samples was measured by the method, and the average time for a single sample analysis was less than 0. 5 min. The recovery rates for different concentrations ranged from 82. 6% to 105. 6%, and the relative standard deviations (RSDs) ranged from 2. 2% to 11. 4%. This study showed that EESI-MS was a powerful tool for the rapid, sensitive, and quantitative detection of amino acids in complex biological samples.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 20 条
  • [1] Early Detection of Recurrent Breast Cancer Using Metabolite Profiling
    Asiago, Vincent M.
    Alvarado, Leiddy Z.
    Shanaiah, Narasimhamurthy
    Gowda, G. A. Nagana
    Owusu-Sarfo, Kwadwo
    Ballas, Robert A.
    Raftery, Daniel
    [J]. CANCER RESEARCH, 2010, 70 (21) : 8309 - 8318
  • [2] A biochemical perspective on the use of tandem mass spectrometry for newborn screening and clinical testing
    Chace, DH
    Kalas, TA
    [J]. CLINICAL BIOCHEMISTRY, 2005, 38 (04) : 296 - 309
  • [3] Sensitive Detection of Native Proteins Using Extractive Electrospray Ionization Mass Spectrometry
    Chen, Huanwen
    Yang, Shuiping
    Li, Ming
    Hu, Bin
    Li, Jianqiang
    Wang, Jiang
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (17) : 3053 - 3056
  • [4] Ding JH, 2009, CHEM J CHINESE U, V30, P1533
  • [5] Selective Detection of Diethylene Glycol in Toothpaste Products Using Neutral Desorption Reactive Extractive Electrospray Ionization Tandem Mass Spectrometry
    Ding, Jianhua
    Gu, Haiwei
    Yang, Shuiping
    Li, Ming
    Li, Jianqiang
    Chen, Huanwen
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (20) : 8632 - 8638
  • [6] GONG Dao-Yuan, 2007, CLIN LAB MED, P101
  • [7] Metabolite Profiling Identifies a Key Role for Glycine in Rapid Cancer Cell Proliferation
    Jain, Mohit
    Nilsson, Roland
    Sharma, Sonia
    Madhusudhan, Nikhil
    Kitami, Toshimori
    Souza, Amanda L.
    Kafri, Ran
    Kirschner, Marc W.
    Clish, Clary B.
    Mootha, Vamsi K.
    [J]. SCIENCE, 2012, 336 (6084) : 1040 - 1044
  • [8] Metabolomics: A global biochemical approach to drug response and disease
    Kaddurah-Daouk, Rima
    Kristal, Bruce S.
    Weinshilboum, Richard M.
    [J]. ANNUAL REVIEW OF PHARMACOLOGY AND TOXICOLOGY, 2008, 48 : 653 - 683
  • [9] Automated GC-MS analysis of free amino acids in biological fluids
    Kaspar, Hannelore
    Dettmer, Katja
    Gronwald, Wolfram
    Oefner, Peter J.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (02): : 222 - 232
  • [10] On the Mechanism of Extractive Electrospray Ionization
    Law, Wai Siang
    Wang, Rui
    Hu, Bin
    Berchtold, Christian
    Meier, Lukas
    Chen, Huanwen
    Zenobi, Renato
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (11) : 4494 - 4500