Multiscale Seismic Vulnerability Assessment and Retrofit of Existing Masonry Buildings

被引:43
|
作者
Ferreira, Tiago Miguel [1 ]
Mendes, Nuno [1 ]
Silva, Rui [1 ]
机构
[1] Univ Minho, Inst Sci & Innovat Biosustainabil IB S, Dept Civil Engn, ISISE, P-4710057 Braga, Portugal
关键词
seismic vulnerability assessment; large-scale vulnerability analysis; numerical modelling; seismic retrofit; DAMAGE SCENARIOS; ELEMENT-ANALYSIS; LIMIT ANALYSIS; FACADE WALLS; EARTHQUAKE; BEHAVIOR; CONNECTIONS; MODEL; RISK; FAILURE;
D O I
10.3390/buildings9040091
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The growing concern about the protection of built heritage and the sustainability of urban areas has driven the reoccupation of existing masonry buildings, which, in the great majority of the cases, were not designed or constructed to withstand significant seismic forces. This fact, associated with territorial occupation often concentrated in areas with high seismic hazard, makes it essential to look at these buildings from the point of view of the assessment of their seismic vulnerability and retrofitting needs. However, to be effective and efficient, such an assessment must be founded on a solid knowledge of the existing methods and tools, as well as on the criteria that should underlie the selection of the most appropriate to use in each context and situation. Aimed at contributing to systematise that knowledge, this paper presents a comprehensive review of the most relevant vulnerability assessment methods applicable at different scales, as well as the most significant traditional and innovative seismic retrofitting solutions for existing masonry buildings.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Reducing the Seismic Vulnerability of Existing Buildings: Assessment and Retrofit
    Ferreira, Tiago Miguel
    Mendes, Nuno
    Silva, Rui
    BUILDINGS, 2019, 9 (06)
  • [2] On the seismic vulnerability of existing unreinforced masonry buildings
    Lang, K
    Bachmann, H
    JOURNAL OF EARTHQUAKE ENGINEERING, 2003, 7 (03) : 407 - 426
  • [3] Intermediate Isolation System for the seismic retrofit of existing masonry buildings
    Faiella, D.
    Argenziano, M.
    Brandonisio, G.
    Esposito, F.
    Mele, E.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 661 - 662
  • [4] Intermediate isolation system for the seismic retrofit of existing masonry buildings
    Faiella, D.
    Argenziano, M.
    Brandonisio, G.
    Esposito, F.
    Mele, E.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 1895 - 1900
  • [5] Damage study and seismic vulnerability assessment of existing masonry buildings in Northeast India
    Halder, Lipika
    Dutta, Sekhar Chandra
    Sharma, Richi Prasad
    JOURNAL OF BUILDING ENGINEERING, 2020, 29
  • [6] Probabilistic Seismic Assessment of Existing Masonry Buildings
    Croce, Pietro
    Landi, Filippo
    Formichi, Paolo
    BUILDINGS, 2019, 9 (12)
  • [7] Seismic vulnerability assessment of Portuguese masonry buildings
    Lovon, Holger
    Silva, Vitor
    Vicente, Romeu
    Ferreira, Tiago Miguel
    STRUCTURES, 2023, 55 : 853 - 865
  • [8] Seismic vulnerability assessment of historical masonry buildings
    Calderoni, B.
    Cordasco, E. A.
    Lenza, P.
    Pacella, G.
    PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 1443 - 1448
  • [9] Seismic vulnerability assessment of masonry buildings in Karachi
    Mohammad A.F.
    Khan R.A.
    Fatima E.B.
    Shaukat E.A.
    Mujtaba E.M.
    Asian Journal of Civil Engineering, 2023, 24 (1) : 137 - 151
  • [10] Assessment of the seismic vulnerability of unreinforced masonry buildings
    Penelis, GG
    Kappos, AJ
    Stylianidis, KC
    STRUCTURAL STUDIES, REPAIRS AND MAINTENANCE OF HERITAGE ARCHITECTURE VIII, 2003, 16 : 575 - 584