Development and validation of a stability-indicating HPLC-UV method for the determination of Thiocolchicoside and its degradation products

被引:8
|
作者
Aprile, Silvio
Canavesi, Rossana
Bianchi, Michele
Grosa, Giorgio
Del Grosso, Erika [1 ]
机构
[1] Univ Piemonte Orientale, Dept Pharmaceut Sci, Largo Donegani 2, I-28100 Novara, Italy
关键词
Thiocolchicoside; HPLC-UV; Degradation products; Validation; Stability indicating method;
D O I
10.1016/j.jpba.2016.09.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stability indicating high performance liquid chromatography method has been developed for the determination of thiocolchicoside (TCC) and its main degradation products thiocolchicoside S-oxide (D1SO) and 3-O-demethylthiocolchicine (D3) in liquid and solid formulations. The method was developed based on a previous forced degradation study showing that TCC underwent chemical degradation by acid/base catalyzed hydrolysis and oxidation being the main degradation products D3 and D1SO respectively. The analytes separation and quantification were achieved on a Synergi (TM) 4 mu m Polar-RP 80 angstrom, column 150 x 4.6 mm (Phenomenex) using the mobile phase constituted (flow rate 1 mL min(-1)) of eluant A: 20 mM sodium acetate buffer (pH 5.0) and eluant B: MeOH:CH3CN (20:80); the elution was performed in gradient mode detecting the analytes at 254 nm. The method showed linearity for TCC assay in the 5-15 mu g mL(-1), range and for unknown (TCCfu) and known (D1SO and D3) degradation products assay, in the 0.5-10 mu g mL(-1) range: all the square of the correlation coefficients were greater than 0.999. The precision, determined in terms of intra-day and inter-day were expressed as RSDs and resulted to be 1.19, 1.10, 1.37 and 1.04% and 0.95, 0.83, 1.30 and 0.72 for TCC, TCCfu D1SO and D3, respectively. The method demonstrated also to be accurate; indeed, the average recoveries were 102.1/102.0% for TCC (ampoules and hard capsules respectively), 101.3/100.3% for TCCfu 101.7/100.2% for D1SO, and 101.4/101.4% for D3. The robustness was also evaluated by variations of mobile phase composition and pH. Finally, the applicability of the method was evaluated by analysis of commercial liquid and solid dosage forms. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [1] Development and validation of a stability-indicating HPLC-UV method for the determination of alizapride and its degradation products
    Tamaro, Ilaria
    Aprile, Silvio
    Giovenzana, Giovanni B.
    Grosa, Giorgio
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (05) : 1024 - 1031
  • [2] Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation
    van Heugten, A. J. P.
    de Boer, W.
    de Vries, W. S.
    Markesteijn, C. M. A.
    Vromans, H.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 149 : 265 - 270
  • [3] Development and validation of a stability-indicating HPLC method for the determination of degradation products in dipyridamole injection
    Zhang, J
    Miller, RB
    Jacobus, R
    [J]. CHROMATOGRAPHIA, 1997, 44 (5-6) : 247 - 252
  • [4] Development and validation of a stability-indicating HPLC method for the determination of degradation products in dipyridamole injection
    J. Zhang
    R. B. Miller
    R. Jacobus
    [J]. Chromatographia, 1997, 44 : 247 - 252
  • [5] Development of Stability Indicating HPLC-UV Method for Determination of Daclatasvir and Characterization of Forced Degradation Products
    Zaman, Bakht
    Hassan, Waseem
    [J]. CHROMATOGRAPHIA, 2018, 81 (05) : 785 - 797
  • [6] Development and Validation of a Stability-indicating HPLC-UV Method for the Simultaneous Determination of Flurbiprofen and Triclosan in Dental Nanogel Formulations
    Aminu, Nafiu
    Chan, Siok-Yee
    Toh, Seok-Ming
    [J]. JOURNAL OF PHYSICAL SCIENCE, 2018, 29 : 1 - 7
  • [7] A Stability-Indicating RP-HPLC-UV method for determination of fidaxomicin and its hydrolytic degradation products
    K. Vinod Kumar
    Hemraj Sharma
    Ramalingam Peraman
    SarvaSree Pudipatla
    [J]. Journal of the Iranian Chemical Society, 2022, 19 : 785 - 792
  • [8] A Stability-Indicating RP-HPLC-UV method for determination of fidaxomicin and its hydrolytic degradation products
    Kumar, K. Vinod
    Sharma, Hemraj
    Peraman, Ramalingam
    Pudipatla, SarvaSree
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (03) : 785 - 792
  • [9] Development and validation of a stability-indicating HPLC method for the simultaneous determination of Losartan potassium, hydrochlorothiazide, and their degradation products
    Hertzog, DL
    McCafferty, JF
    Fang, XG
    Tyrrell, RJ
    Reed, RA
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 747 - 760
  • [10] Development of Stability Indicating HPLC-UV Method for Determination of Process Impurities and Degradation Products in Sofosbuvir and Velpatasvir Tablets
    Bakht Zaman
    Waseem Hassan
    [J]. Pharmaceutical Chemistry Journal, 2021, 54 : 1295 - 1305