Influence of endotracheal tube diameter on forced deflation flow-volume curves in rhesus monkeys

被引:11
|
作者
Hammer, J [1 ]
Newth, CJL [1 ]
机构
[1] UNIV SO CALIF, CHILDRENS HOSP LOS ANGELES, SCH MED, DIV PEDIAT CRIT CARE, LOS ANGELES, CA 90089 USA
关键词
flow limitation; forced expiration; forced vital capacity; infant pulmonary function testing; maximum expiratory flow-volume curves;
D O I
10.1183/09031936.97.10081870
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The forced deflation (FD) technique is the recommended gold standard to generate forced expiratory vital capacity (FVC) curves and to measure maximum expiratory flow-volume (MEFV) relationships in intubated infants and children, However, the influence of the endotracheal tube (ETT) on the site of flow limitation, the shape and the analysis of the resultant MEFV curves have not been defined. Nine anaesthetized (thiopentone, 8 mg.kg(-1).h(-1)) rhesus monkeys (mean weight (+/- SEM) 10 +/- 1 kg) were intubated consecutively with ETTs of different internal diameters (ID 3.0-5.5 mm, at intervals of 0.5 mm); the largest representing the appropriate ETT size for the animal. Quadruplicate MEFV curves were generated by FD using the standard +40 cmH(2)Oinsp/-40 cmH(2)Oexp pressures and recorded at each ETT diameter. The effect of the different ETT diameters on the FD flow-volume curve was analysed by comparing maximum expiratory flows at isovolume points at 50, 25 and 10% FVC (MEF50, MEF25 and MEF10, respectively), The shape of the resulting MEFV curves could be divided into an initial horizontal part (tube-dependent), and a final descending slope (airway-dependent). No difference in FVC occurred irrespective of the ETT size (p > 0.05 by analysis of variance (ANOVA)), MEF50 increased with increasing tube diameter (p < 0.05). MEF25 remained unchanged using ETTs which were less than 1.5 mm smaller than the largest ETT, Smaller ETTs resulted in significantly reduced MEF25 (p < 0.05). MEF10 was not influenced by the ETT size. We conclude that maximum expiratory flows measured by the forced deflation technique are not influenced by an appropriately sized endotracheal tube at lung volumes below 25% forced vital capacity in our monkey model with normal lungs, We postulate that the effect of endotracheal tubes on maximum expiratory flow volume curves in intubated infants might be of similar or even smaller magnitude, which remains to be established.
引用
收藏
页码:1870 / 1873
页数:4
相关论文
共 50 条
  • [1] THE EFFECTS OF VARYING INFLATION AND DEFLATION PRESSURES ON THE MAXIMAL EXPIRATORY DEFLATION FLOW-VOLUME RELATIONSHIP IN ANESTHETIZED RHESUS-MONKEYS
    NEWTH, CJL
    AMSLER, B
    ANDERSON, GP
    MORLEY, J
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (04): : 807 - 813
  • [2] FLOW-VOLUME CURVES AND TOTAL PULMONARY RESISTANCE IN NORMAL BONNET AND RHESUS-MONKEYS
    KOSCH, PC
    GILLESPIE, JR
    BERRY, JD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (01) : 176 - 183
  • [3] SHAPE OF FORCED EXPIRATORY FLOW-VOLUME CURVES IN INFANTS
    LESOUEF, PN
    HUGHES, DM
    LANDAU, LI
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 138 (03): : 590 - 597
  • [4] Effort and volume dependence of forced-deflation flow-volume relationships in intubated infants
    Hammer, JH
    Newth, CJL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (01) : 345 - 350
  • [5] DEFLATION FLOW-VOLUME CURVES (DFVC) FOR ASSESSMENT OF RESPIRATORY-FAILURE IN INFANTS
    MOTOYAMA, EK
    OH, TH
    BRINKMEYER, SD
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (03) : 288 - 288
  • [6] FORCED EXPIRATORY FLOW-VOLUME CURVES IN INFANTS AND YOUNG-CHILDREN
    BEARDSMORE, CS
    GODFREY, S
    SILVERMAN, M
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1989, 2 : S154 - S159
  • [7] PARTIAL FLOW-VOLUME CURVES
    ZAMEL, N
    [J]. BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1984, 20 (06): : 471 - 475
  • [8] LOOPS AND NO FLOW-VOLUME CURVES
    RODRIGUEZROISIN, R
    [J]. MEDICINA CLINICA, 1980, 75 (04): : 177 - 177
  • [9] Pulmonary Function Testing Via Forced Deflation Flow-Volume Curve Machine In Expired Swine
    Salvador, T.
    Leatherbury, L.
    Cleary, K.
    Shukla, P. J.
    Sami-Zakhari, I. R.
    Grefe, R.
    Crowder, G.
    Bangoura, A.
    Koumbourlis, A. C.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [10] CALIBRATION OF FLOW-VOLUME CURVES
    BOUHUYS, A
    VIRGULTO, JA
    [J]. LUNG, 1978, 155 (02) : 123 - 130