DEFORMABLE REGISTRATION MODEL WITH LOCAL RIGIDITY PRESERVATION FOR RADIATION THERAPY OF LUNG TUMOR

被引:0
|
作者
Zheng, Chaojie [1 ]
Wang, Xiuying [1 ]
Chen, Jinhu [2 ]
Yin, Yong [2 ]
Feng, Dagan [1 ,3 ,4 ]
机构
[1] Univ Sydney, Biomed & Multimedia Informat Technol Res Grp, Sydney, NSW, Australia
[2] Shandong Tumor Hosp, Dept Radiat Oncol, Jinan, Shandong, Peoples R China
[3] Hong Kong Polytech Univ, Ctr Multimedia Signal Proc, Hong Kong, Hong Kong, Peoples R China
[4] Shanghai Jiao Tong Univ, Med X Res Inst, Shanghai, Peoples R China
关键词
image registration; local rigidity preservation; radiation therapy; lung tumor; CT; SEGMENTATION; ACCURATE;
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Deformable registration has an important application in radiation therapy and evaluation of patient response to the treatment. However, the conventional deformable registration may introduce excessive deformation on tumor shape and volume, which thereby may lead to less accurate dose delivery on the targeted tumor and possible lesion on the surrounding healthy organs. In this paper, we proposed a deformable registration model to preserve accurate tumor information while retaining the global alignment of the temporal or multimodal biomedical images. Our experimental results on 12 clinical datasets with 15 tumors demonstrated that our deformable model was able to maintain the unique pathological features of the tumor and provide appropriate alignment and correspondence.
引用
收藏
页码:1673 / 1676
页数:4
相关论文
共 50 条
  • [1] Deformable image registration with guaranteed local rigidity
    Koenig, L.
    Derksen, A.
    Heldmann, S.
    Papenberg, N.
    Modersitzki, J.
    Haas, B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S197 - S198
  • [2] Deformable registration using regularization that accommodates local tissue rigidity
    Ruan, D.
    Fessler, J.
    Roberson, M.
    Balter, J.
    Kessler, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2186 - 2186
  • [3] Topology Guided Demons Registration with Local Rigidity Preservation
    Zheng, Chaojie
    Wang, Xiuying
    Feng, Dagan
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1171 - 1174
  • [4] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259
  • [5] DEFORMABLE IMAGE REGISTRATION FOR RADIATION THERAPY
    Sarrut, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S47 - S47
  • [6] Tumor Motion Tracking with a Regional Deformable Registration Model for Four Dimensional Radiation Treatment of Lung Cancer
    Chao, M.
    Lo, Y.
    Yuan, Y.
    Sheu, R.
    Rosenzweig, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 118 - 118
  • [7] Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
    Koenig, Lars
    Derksen, Alexander
    Papenberg, Nils
    Haas, Benjamin
    RADIATION ONCOLOGY, 2016, 11
  • [8] Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
    Lars König
    Alexander Derksen
    Nils Papenberg
    Benjamin Haas
    Radiation Oncology, 11
  • [9] IMPROVEMENT OF ACCURACY IN DEFORMABLE REGISTRATION IN RADIATION THERAPY
    Ye, Xiaojing
    Chen, Yunmei
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 2420 - 2423
  • [10] Tumor Tracking for Adaptive Radiation Therapy System by Multiresolution Wavelet Deformable Registration Framework
    Li, D.
    Yin, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S727 - S727