Test-Retest Reliability and Minimal Detectable Change for the 10-Meter Walk Test in Older Adults With Parkinson's disease

被引:82
|
作者
Lang, Jesse T. [1 ]
Kassan, Thomas O. [1 ]
Devaney, Laurie Lee [1 ]
Colon-Semenza, Cristina [1 ]
Joseph, Michael F. [1 ]
机构
[1] Univ Connecticut, Dept Kinesiol, Coll Agr Hlth & Nat Resources, Phys Therapy Program, Storrs, CT USA
关键词
gait speed; geriatric; Parkinson's disease; reliability; step frequency; PAIN INTENSITY; GAIT; SPEED; RESPONSIVENESS; PROGRESSION; AMBULATION; DIAGNOSIS; VALIDITY; PEOPLE; STROKE;
D O I
10.1519/JPT.0000000000000068
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background and Purpose: Measurement of gait performance in individuals with Parkinson's disease (PD) can be challenging because of the daily fluctuations in performance and the progressive nature of the condition. The 10-Meter Walk Test (10MWT) is commonly used to measure gait speed of individuals with gait limitations. Existing research on the 10MWT in individuals with PD controls for many variables inherent to this condition, rendering the results of this test in settings where these variables are not controlled questionable. The purpose of this study was to estimate under commonly encountered clinical conditions the test-retest reliability and the minimal detectable change (MDC) of gait speed and step frequency determined during the 10MWT in individuals with PD. Methods: The 10MWT was administered by 2 testers, on 35 participants, across 2 sessions, separated by 5 to 14 days. Gait speed was measured using a hand-held stopwatch, and step frequency was assessed through visual observation. Test-retest reliability was calculated using the intraclass correlation coefficient (ICC) and the MDC was calculated using the standard error of measurement (SEM). Results and Discussion: Comfortable and fast gait speeds demonstrated excellent reliability between sessions (ICC = 0.92 and 0.96, respectively). The corresponding MDCs were 0.22 and 0.23 m/s, respectively. The test-retest reliability for step frequency was moderate for comfortable gait speed and good for fast gait speeds (ICC = 0.73 and 0.82, respectively). The corresponding MDCs were 15.1 and 17.4 steps per minute for comfortable and fast step frequency, respectively. Conclusions: Under both comfortable and fast conditions, measurements of gait speed and step frequency during the 10MWT are reliable between sessions in individuals with PD.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [1] Reliability, validity and minimal detectable change of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with dementia
    Chan, Wayne L. S.
    Pin, Tamis W.
    EXPERIMENTAL GERONTOLOGY, 2019, 115 : 9 - 18
  • [2] Test-retest reliability of the 10-meter walk test in ambulatory adults with motor-complete spinal cord injury
    Rini, Dhairiamani
    Senthilvelkumar, Thangavelu
    Noble, Koshy
    Magimairaj, Henryprakash
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2018, 25 (07): : 335 - 339
  • [3] TEST-RETEST RELIABILITY AND MINIMAL DETECTABLE CHANGE OF THE HEXAGON AGILITY Test
    Beekhuizen, Kristina S.
    Davis, Maurice D.
    Kolber, Morey J.
    Cheng, Ming-Shun S.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (07) : 2167 - 2171
  • [4] The Test-Retest Reliability and Minimal Detectable Change of the FitLight TrainerTM
    Myers, Lauren R.
    Toonstra, Jenny L.
    Cripps, Andrea E.
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2022, : 84 - 88
  • [5] Test-retest reliability and minimal detectable change of the Contextual Memory Test in older adults with and without mild cognitive impairment
    Liao, Wan-wen
    Wu, Ching-yi
    Liu, Chien-Hsiou
    Lin, Szu-hung
    Chiau, Hui-Yan
    Chen, Chia-ling
    PLOS ONE, 2020, 15 (07):
  • [6] The test-retest reliability and the minimal detectable change of the Purdue pegboard test in schizophrenia
    Lee, Posen
    Liu, Chin-Hsuan
    Fan, Chia-Wei
    Lu, Chi-Pang
    Lu, Wen-Shian
    Hsieh, Ching-Lin
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2013, 112 (06) : 332 - 337
  • [7] Test-Retest Reliability and Minimal Detectable Change of the Instrumented Modified Clinical Test of Sensory Interaction on Balance in Healthy, Older Adults
    Watson, Seth
    Trudelle-Jackson, Elaine
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2021, 44 (04) : 183 - 188
  • [8] Test-Retest Reliability and Minimal Detectable Change of Four Cognitive Tests in Community-Dwelling Older Adults
    Webb, Katherine L.
    Ryan, Joanne
    Wolfe, Rory
    Woods, Robyn L.
    Shah, Raj C.
    Murray, Anne M.
    Orchard, Suzanne G.
    Storey, Elsdon
    JOURNAL OF ALZHEIMERS DISEASE, 2022, 87 (04) : 1683 - 1693
  • [9] Test-Retest Reliability and Minimal Detectable Change Scores for Fitness Assessment in Older Adults with Type 2 Diabetes
    Alfonso-Rosa, Rosa M.
    del Pozo-Cruz, Borja
    del Pozo-Cruz, Jesus
    Sanudo, Borja
    Rogers, Michael E.
    REHABILITATION NURSING, 2014, 39 (05) : 260 - 268
  • [10] Test-Retest Reliability and Minimal Detectable Change of the SmartWheel Clinical Protocol
    Lui, Jordon
    MacGillivray, Megan K.
    Sawatzky, Bonita J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (12): : 2367 - 2372