Improving indoor air quality and thermal comfort in residential kitchens with a new ventilation system

被引:53
|
作者
Liu, Sumei [1 ,2 ]
Cao, Qing [3 ]
Zhao, Xingwang [1 ,2 ]
Lu, Zechao [2 ]
Deng, Zhipeng [2 ]
Dong, Jiankai [4 ,5 ]
Lin, Xiaorui [6 ]
Qing, Ke [6 ]
Zhang, Weizhen [6 ]
Chen, Qingyan [2 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin, Peoples R China
[2] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[3] Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China
[4] Harbin Inst Technol, Sch Architecture, Harbin 150006, Heilongjiang, Peoples R China
[5] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement E, Beijing, Peoples R China
[6] Vanke Real Estate Dev Co Ltd, Changsha Vanke 410000, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal comfort; Indoor air quality; RNG k-epsilon model; Air conditioning; CFD; CAPTURE EFFICIENCY; SPILLAGE CHARACTERISTICS; RANGE HOOD; COOKING; SENSATION; TEMPERATURE; POLLUTANTS; DEPOSITION; CURTAIN; MODEL;
D O I
10.1016/j.buildenv.2020.107016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Chinese kitchen environment is usually hot and humid in summer and cold in winter, while people spends considerable time there. This investigation firstly assessed the indoor air quality and thermal environment in a kitchen in summer in Changsha, China. Sixteen cooks were asked to prepare the same dishes in the kitchen. The study measured skin temperatures of the cooks and environmental parameters (air temperature, CO, CO2, TVOCs, and PM2.5) and recorded their thermal sensation votes using questionnaires at the same time. The results show that the thermal environment in the kitchen was highly non-uniform and too hot in summer. The air temperature in the kitchen could increase 5.3 degrees C during cooking. TVOCs and PM2.5 concentrations exceeded the limits by Chinese standards in the kitchen. Thus, this investigation proposed a new ventilation system to improve the indoor environment in Chinese residential kitchens. The new ventilation system had upward air curtains around the gas stove and conditioned air from the cabinet under the stove. A systematic numerical study using the steady state RNG k-epsilon model was performed to optimize the integrated system design for both summer and winter conditions. Experimental measurements were conducted in a kitchen mockup to verify the performance of the new system. The measured capture efficiency of the new system was 96.2%-97.1%, the predicted dissatisfied percentage (PD) distribution around the cook smaller than 20%, and the vertical temperature difference between head and feet -0.9 degrees C.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Air quality and thermal comfort in kitchens
    Kajtár, L
    Bánhidi, L
    Leitner, A
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2371 - 2375
  • [2] Indoor thermal environment and air quality in Chinese-style residential kitchens
    Liu, Sumei
    Dong, Jiankai
    Cao, Qing
    Zhou, Xiaojie
    Li, Jian
    Lin, Xiaorui
    Qing, Ke
    Zhang, Weizhen
    Chen, Qingyan
    INDOOR AIR, 2020, 30 (02) : 198 - 212
  • [3] Study of indoor air quality and thermal comfort in a room with displacement ventilation
    Li, Y
    Wang, X
    Li, J
    Sun, Y
    Jia, H
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1027 - 1032
  • [4] AIR-QUALITY AND THERMAL COMFORT IN PROFESSIONAL KITCHENS
    HALTTUNEN, M
    AALTO, E
    INTERNATIONAL SYMPOSIUM - ENERGY OPTIONS FOR THE YEAR 2000 : CONTEMPORARY CONCEPTS IN TECHNOLOGY AND POLICY, VOLS 1-4: ENERGY SYSTEM ; TECHNOLOGY FUTURES : ENERGY BUILDINGS ; INTERNATIONAL COOPERATION, 1988, : C17 - C21
  • [5] Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads
    Noh, Kwang-Chul
    Jang, Jae-Soo
    Oh, Myung-Do
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (01) : 57 - 66
  • [6] NUMERICAL INVESTIGATIONS OF EFFECT OF INDOOR AIR QUALITY ON THERMAL COMFORT IN RESIDENTIAL BUILDINGS
    Krzaczek, M.
    Tejchman, J.
    ARCHIVES OF CIVIL ENGINEERING, 2014, 60 (01) : 91 - 121
  • [7] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [8] Numerical study of Indoor Air Quality and thermal comfort under stratum ventilation
    Tian, Lin
    Lin, Zhang
    Liu, Jing
    Wang, Qiuwang
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2008, 8 (7-8): : 541 - 548
  • [9] Enhancing indoor air quality and thermal comfort in indoor swimming pool facilities: investigating the impact of ventilation system configurations
    Hanafi A.M.
    Ibrahim M.A.
    Abou-deif T.M.
    Morcos S.M.
    Journal of Engineering and Applied Science, 2023, 70 (01):
  • [10] GAS-FIRED HEATERS AND VENTILATION SYSTEM IMPROVE INDOOR AIR-QUALITY AND THERMAL COMFORT
    LIENHART, TG
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1994, 36 (03): : 47 - 49