A novel in chemico method to detect skin sensitizers in highly diluted reaction conditions

被引:43
|
作者
Yamamoto, Yusuke [1 ]
Tahara, Haruna [1 ]
Usami, Ryota [1 ]
Kasahara, Toshihiko [1 ]
Jimbo, Yoshihiro [2 ]
Hioki, Takanori [1 ]
Fujita, Masaharu [1 ]
机构
[1] FUJIFILM Corp, Safety Evaluat Ctr, Minamiashigara, Kanagawa, Japan
[2] FUJIFILM Corp, Synthet Organ Chem Labs, Shizuoka, Japan
关键词
skin sensitization; prediction; direct peptide reactivity assay (DPRA); amino acid derivative reactivity assay (ADRA); NAC; NAL; ADRA-DM (ADRA-dilutional method); PEPTIDE REACTIVITY; VITRO PREDICTION; IDENTIFICATION; ALLERGENS; ADDUCTS; BINDING; LYSINE; ASSAY;
D O I
10.1002/jat.3139
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The direct peptide reactivity assay (DPRA) is a simple and versatile alternative method for the evaluation of skin sensitization that involves the reaction of test chemicals with two peptides. However, this method requires concentrated solutions of test chemicals, and hydrophobic substances may not dissolve at the concentrations required. Furthermore, hydrophobic test chemicals may precipitate when added to the reaction solution. We previously established a high-sensitivity method, the amino acid derivative reactivity assay (ADRA). This method uses novel cysteine (NAC) and novel lysine derivatives (NAL), which were synthesized by introducing a naphthalene ring to the amine group of cysteine and lysine residues. In this study, we modified the ADRA method by reducing the concentration of the test chemicals 100-fold. We investigated the accuracy of skin sensitization predictions made using the modified method, which was designated the ADRA-dilutional method (ADRA-DM). The predictive accuracy of the ADRA-DM for skin sensitization was 90% for 82 test chemicals which were also evaluated via the ADRA, and the predictive accuracy in the ADRA-DM was higher than that in the ADRA and DPRA. Furthermore, no precipitation of test compounds was observed at the initiation of the ADRA-DM reaction. These results show that the ADRA-DM allowed the use of test chemicals at concentrations two orders of magnitude lower than that possible with the ADRA. In addition, ADRA-DM does not have the restrictions on test compound solubility that were a major problem with the DPRA. Therefore, the ADRA-DM is a versatile and useful method. Copyright (c) 2015 John Wiley & Sons, Ltd. We modified the ADRA (amino acid derivative reactivity assay) method by reducing the test chemical concentration in the solution 100-fold. We investigated the accuracy of skin sensitization predictions made using this modified method, which was designated the ADRA-dilutional method (ADRA-DM). The predictive accuracy of the ADRA-DM for skin sensitization was 90% for 82 test chemicals, and no precipitation of test compounds was observed. These results show that the ADRA-DM is a versatile and useful method to predict skin sensitization.
引用
收藏
页码:1348 / 1360
页数:13
相关论文
共 45 条
  • [1] Novel method for polymer thin film preparation: Spray deposition of highly diluted polymer solutions
    Fujita, K
    Ishikawa, T
    Tsutsui, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (1AB): : L70 - L72
  • [2] A Novel Method to Detect Heat Illness Under Severe Conditions by Monitoring Tympanic Temperature
    Yamakoshi, Takehiro
    Matsumura, Kenta
    Rolfe, Peter
    Tanaka, Naoto
    Yamakoshi, Yasuhiro
    Takahashi, Kiichi
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2013, 84 (07): : 692 - 700
  • [3] Development of a novel method to detect clothing level and facial skin temperature for controlling HVAC systems
    Li, Xuan
    Chen, Qingyan
    ENERGY AND BUILDINGS, 2021, 239
  • [4] REACTION OF PHOSPHORAMIDES WITH ISOCYANATES IN PTC CONDITIONS - NOVEL METHOD OF SYNTHESIS OF CARBODIIMIDES
    JASZAY, ZM
    PETNEHAZY, I
    TOKE, L
    PHOSPHORUS SULFUR AND SILICON AND THE RELATED ELEMENTS, 1987, 30 (3-4): : 687 - 687
  • [5] A novel method for evaluating the effect of pollution on the human skin under controlled conditions
    Curpen, Seerooven
    Francois-Newton, Veronique
    Moga, Alain
    Hosenally, Muzzammil
    Petkar, Gitanjali
    Soobramaney, Vitisha
    Ruchaia, Bryna
    Kolanthan, Vimi Lutchmanen
    Roheemun, Naailah
    Sokeechand, Bibi N.
    Aumeeruddy, Zaahira
    Ramracheya, Reshma D.
    SKIN RESEARCH AND TECHNOLOGY, 2020, 26 (01) : 50 - 60
  • [6] Lithium bromide, a novel and highly effective catalyst for monothioacetalization of acetals under mild reaction conditions
    Ono, F
    Negoro, R
    Sato, T
    SYNLETT, 2001, (10) : 1581 - 1583
  • [7] Film quality in relation to deposition conditions of a-Si:H films deposited by the ''hot wire'' method using highly diluted silane
    Molenbroek, EC
    Mahan, AH
    Johnson, EJ
    Gallagher, AC
    JOURNAL OF APPLIED PHYSICS, 1996, 79 (09) : 7278 - 7292
  • [8] A novel adaptive lane change method in transient dynamic traffic conditions for highly automated vehicles
    Rafat, Mohsen
    Azadi, Shahram
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART K-JOURNAL OF MULTI-BODY DYNAMICS, 2021, 235 (03) : 499 - 513
  • [9] N-bromosuccinimide (NBS), a novel and highly effective catalyst for acetylation of alcohols under mild reaction conditions
    Karimi, B
    Seradj, H
    SYNLETT, 2001, (04) : 519 - 520
  • [10] A novel method to detect mutation in DNA by utilizing exponential amplification reaction triggered by the CRISPR-Cas9 system
    Song, Jayeon
    Kim, Soohyun
    Kim, Hyo Yong
    Hur, Kyung Hoon
    Kim, Yoosik
    Park, Hyun Gyu
    NANOSCALE, 2021, 13 (15) : 7193 - 7201