DEVELOPMENT AND CHARACTERIZATION OF A SENSOR BASED ON CARBON NANOFIBERS: APPLICATION TO ACETAZOLAMIDE DETERMINATION IN PHARMACEUTICALS AND BIOLOGICAL FLUIDS

被引:2
|
作者
Mundaca-Uribe, Rodolfo [1 ]
De Diego, Marta [1 ]
Henriquez-Aedo, Karem [2 ]
Aranda, Mario [2 ]
Pena-Farfal, Carlos [3 ]
机构
[1] Univ Concepcion, Fac Farm, Dept Farm, Concepcion 4070043, Chile
[2] Univ Concepcion, Dept Ciencia & Tecnol Alimentos, Fac Farm, Concepcion 4070043, Chile
[3] Univ Concepcion, Fac Ciencias Quim, Dept Quim Analit, Concepcion 4070371, Chile
来源
关键词
ELECTROCHEMICAL SENSOR; SENSITIVE DETERMINATION; HUMAN URINE; HUMAN SERUM; NANOTUBES; ELECTRODE; SURFACE;
D O I
10.4067/s0717-97072019000104382
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acetazolamide (ACZ) is a carbonic anhydrase inhibitor that exhibits diuretic activity. In medicine, it is principally used in open-angle glaucoma. for prevention or amelioration of symptoms associated with acute high-altitude sickness and as an adjunct to other anticonvulsants in centrencephalic epilepsies. Furthermore, ACZ is sometimes used by athletes to mask the presence of doping substances, so its use has been banned in competitions. The aim of this work was the development of a sensor to determine ACZ, in pharmaceuticals. as quality control way, and serum, for clinical and doping analyzes. The sensor has been developed modifying a glassy carbon electrode with carbon nanofibers. The electrochemical characterization of the sensor was performed by cyclic voltammetry using the redox mediator potassium ferrocyanide. ACZ electiuchemical behavior was studied as well. Measurements were performed in a conventional three electrodes cell using differential pulse voltammetry. The influence of some experimental variables involved in the preparation and performance of the sensor -amount of modifier, supporting electrolyte, pH, scan rate and pulse amplitude- were optimized. This methodology provided a linear calibration plot for ACZ in the 1 - 17 AM concentration range. Furthermore, the proposed sensor exhibited suitable analytical properties, with detection and quantification limits of 0.06 mu M and 0.2 mu M respectively; analytical sensitivity of 1.142 mu A mu M, repeatability of 0.72 %, and it was applied to determine ACZ, in pharmaceuticals (tablets) and spiked human serum, being an excellent tool to perform quality control and antidoping control.
引用
收藏
页码:4382 / 4385
页数:4
相关论文
共 50 条
  • [1] Carbon Paste Sensor for the Determination of an Anticancer Drug Paclitaxel in Pharmaceuticals and Biological Fluids
    Gowda, Jayant I.
    Nandibewoor, Sharanappa T.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 539 - 554
  • [2] A selective and sensitive voltammetric sensor based on molecularly imprinted polymer for the determination of dipyridamole in pharmaceuticals and biological fluids
    Javanbakht, Mehran
    Fathollahi, Fatemeh
    Divsar, Faten
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 : 362 - 367
  • [3] Voltammetric determination of cefixime in pharmaceuticals and biological fluids
    Jain, Rajeev
    Gupta, Vinod K.
    Jadon, N.
    Radhapyari, K.
    ANALYTICAL BIOCHEMISTRY, 2010, 407 (01) : 79 - 88
  • [4] Fluorimetric determination of isoxsuprine hydrochloride in pharmaceuticals and biological fluids
    Alarfaj, NAA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (02) : 331 - 335
  • [5] Analytical methods for vancomycin determination in biological fluids and in pharmaceuticals
    Duarte Carvalho Vila, Marta Maria
    de Oliveira, Robson Machado
    Goncalves, Marcos Moises
    Tubino, Matthieu
    QUIMICA NOVA, 2007, 30 (02): : 395 - 399
  • [6] Spectrophotometric and chromatographic determination of sulfanilamides in biological fluids and pharmaceuticals
    M. I. Evgen’ev
    S. Yu. Garmonov
    L. Sh. Shakirova
    F. S. Levinson
    Journal of Analytical Chemistry, 2000, 55 : 799 - 805
  • [7] SPECTROFLUOROMETRIC DETERMINATION OF PARACETAMOL IN PHARMACEUTICALS AND BIOLOGICAL-FLUIDS
    VILCHEZ, JL
    BLANC, R
    AVIDAD, R
    NAVALON, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (09) : 1119 - 1125
  • [8] Spectrophotometric and chromatographic determination of sulfanilamides in biological fluids and pharmaceuticals
    Evgen'ev, MI
    Garmonov, SY
    Shakirova, LS
    Levinson, FS
    JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (08) : 799 - 805
  • [9] Development and validation of a rapid HPLC method for the direct determination of colchicine in pharmaceuticals and biological fluids
    Samanidou, VF
    Sarantis, GA
    Papadoyannis, IN
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (01) : 1 - 13
  • [10] Nanogold based electrochemical sensor for determination of norepinephrine in biological fluids
    Goyal, Rajendra N.
    Aziz, Md Abdul
    Oyama, Munetaka
    Chatterjee, Sanghamitra
    Rana, Anoop Raj Singh
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 232 - 238