Squareness error calibration of a CMM for quality control of ophthalmic lenses

被引:3
|
作者
Rodriguez-Ibanez, Diego [1 ]
Alonso, Jose [1 ]
Antonio Quiroga, Juan [1 ]
机构
[1] Univ Complutense Madrid, Dept Opt, Madrid, Spain
来源
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY | 2013年 / 68卷 / 1-4期
关键词
CMM; Calibration; Squareness error; Volumetric error; Ophthalmic lenses quality control;
D O I
10.1007/s00170-013-4746-y
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a calibration procedure for the squareness error of small-sized coordinate measuring machines like those used for ophthalmic lenses quality control. The proposed procedure only requires a spherical lens as a reference surface and it only needs to be measured once making this calibration method faster and cheaper than the existing ones.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [1] Squareness error calibration of a CMM for quality control of ophthalmic lenses
    Diego Rodríguez-Ibáñez
    José Alonso
    Juan Antonio Quiroga
    The International Journal of Advanced Manufacturing Technology, 2013, 68 : 487 - 493
  • [2] Error analysis on squareness of multi-sensor integrated CMM for the multistep registration method
    Zhao, Yan
    Wang, Yiwen
    Ye, Xiuling
    Wang, Zhong
    Fu, Luhua
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [3] Evaluation of error in the performance of power corrected ophthalmic lenses
    Trujillo-Schiaffino, Gerardo
    Patricia Salas-Peimbert, Didia
    Anguiano-Morales, Marcelino
    Malacara-Doblado, Daniel
    Vega-Pineda, Javier
    OPTICA APPLICATA, 2013, 43 (02) : 261 - 270
  • [4] Optical Characterisation of Myopia Control Ophthalmic Lenses
    Esfandiarijahromi, Hassan
    Ho, Arthur
    Back, Arthur
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [5] A Hole-Plate Artifact Design for the Volumetric Error Calibration of CMM
    E.S. Lee
    M. Burdekin
    The International Journal of Advanced Manufacturing Technology, 2001, 17 : 508 - 515
  • [6] A hole-plate artifact design for the volumetric error calibration of CMM
    Lee, ES
    Burdekin, M
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2001, 17 (07): : 508 - 515
  • [7] High accurate measurement and calibration of the squareness on ultra-precision machine based on error separation
    Lai, Tao
    Peng, Xiaoqiang
    Liu, Junfeng
    Tie, Guipeng
    Guo, Meng
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2019, 233 (02) : 600 - 609
  • [8] Error of calibration in ophthalmic calipers: a source of significant clinical errors
    Dahrab, Mishari Mohammed
    LaRoche, G. Robert
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2011, 46 (06): : 510 - 512
  • [9] SOURCES OF ERROR IN AND CALIBRATION OF THE F-NUMBER OF PHOTOGRAPHIC LENSES
    WASHER, FE
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1948, 41 (04): : 301 - 313
  • [10] Surface and geometry error modeling in brittle mode grinding of ophthalmic lenses moulds
    Meneghello, R.
    Concheri, G.
    Savio, G.
    Comelli, D.
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2006, 46 (12-13): : 1662 - 1670