A Potentiometric Sensor for Cd2+ Based on Carbon Nanotube Paste Electrode Constructed from Room Temperature Ionic Liquid, Ionophore and Silica Nanoparticles

被引:51
|
作者
Afkhami, Abbas [1 ]
Bagheri, Hasan [2 ]
Shirzadmehr, Ali [1 ]
Khoshsafar, Hosein [1 ]
Hashemi, Pegah [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan, Iran
[2] Islamic Azad Univ, Dept Chem, Takestan Branch, Takestan, Iran
关键词
Potentiometric sensors; Modified carbon paste electrodes; Cadmium(II) determination; Multiwalled carbon nanotubes; Room temperature ionic liquids; POLYMERIC MEMBRANE ELECTRODES; HEAVY-METAL IONS; ENVIRONMENTAL-SAMPLES; POLY(VINYL CHLORIDE); SELECTIVE ELECTRODES; SCHIFF-BASES; CADMIUM; PRECONCENTRATION; COMPOSITES; LIGAND;
D O I
10.1002/elan.201200246
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and effective potentiometric sensor for the rapid determination of Cd2+ based on carbon paste electrode consisting of the room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate, multiwalled carbon nanotubes, silica nanoparticles and ionophore was constructed. The prepared composite has a low potential drift, high selectivity and fast response time, which leads to a more stable potential signal. A linear dynamic range of 4.50x10(-9)1.00x10(-1) mol L-1 with a detection limit of 2.00x10(-9) mol L-1 was obtained. The modified electrode was successfully applied to the accurate determination of trace amounts of Cd2+ in environmental and biological samples.
引用
收藏
页码:2176 / 2185
页数:10
相关论文
共 50 条
  • [1] An electrochemical biosensor for α-fetoprotein based on carbon paste electrode constructed of room temperature ionic liquid and gold nanoparticles
    Ding, Caifeng
    Zhao, Fei
    Ren, Rui
    Lin, Jin-Ming
    [J]. TALANTA, 2009, 78 (03) : 1148 - 1154
  • [2] Octaethylporphyrin as an ionophore for aluminum potentiometric sensor based on carbon paste electrode
    Soleimani, Majid
    Afshar, Majid Ghahraman
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (06) : 554 - 560
  • [3] Octaethylporphyrin as an ionophore for aluminum potentiometric sensor based on carbon paste electrode
    Majid Soleimani
    Majid Ghahraman Afshar
    [J]. Russian Journal of Electrochemistry, 2014, 50 : 554 - 560
  • [4] Highly sensitive voltammetric sensor based on NiO nanoparticle room temperature ionic liquid modified carbon paste electrode for levodopa analysis
    Fouladgar, Masoud
    Karimi-Maleh, Hassan
    Gupta, Vinod Kumar
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2015, 208 : 78 - 83
  • [5] Evaluation of a carbon paste electrode modified with Ionic liquid and MnO nanoparticles in the Cu(II) determination by Potentiometric Method
    Mosazadeh, Mona
    Ebrahimi, Mahmoud
    Morsali, Ali
    [J]. ENTOMOLOGY AND APPLIED SCIENCE LETTERS, 2016, 3 (04): : 33 - 38
  • [6] Carbon Paste Electrode Modified with Bismuth Oxychloride as a Sensor for the Determination of Pb2+ and Cd2+
    Liu, Lu
    Yu, Chen
    Zhang, Xinxin
    Ma, Hongchao
    Ma, Chun
    Fu, Yinghuan
    Dong, Xiaoli
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4469 - 4482
  • [7] Silica gel/gold nanoparticles/(NS)2 ligand nanoporous platform-modified ionic liquid carbon paste electrode for potentiometric ultratrace assessment of Ag(I)
    Ramezani, S.
    Mashhadizadeh, M. H.
    Ghobadi, M.
    Jalilian, S.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2016, 13 (09) : 2175 - 2188
  • [8] Simultaneous Determination of Amaranth and Nitrite in Foodstuffs via Electrochemical Sensor Based on Carbon Paste Electrode Modified with CuO/SWCNTs and Room Temperature Ionic Liquid
    Majede Bijad
    Hassan Karimi-Maleh
    Mohammad Farsi
    Seyed-Ahmad Shahidi
    [J]. Food Analytical Methods, 2017, 10 : 3773 - 3780
  • [9] Simultaneous Determination of Amaranth and Nitrite in Foodstuffs via Electrochemical Sensor Based on Carbon Paste Electrode Modified with CuO/SWCNTs and Room Temperature Ionic Liquid
    Bijad, Majede
    Karimi-Maleh, Hassan
    Farsi, Mohammad
    Shahidi, Seyed-Ahmad
    [J]. FOOD ANALYTICAL METHODS, 2017, 10 (11) : 3773 - 3780
  • [10] Silica gel/gold nanoparticles/(NS)2 ligand nanoporous platform-modified ionic liquid carbon paste electrode for potentiometric ultratrace assessment of Ag(I)
    S. Ramezani
    M. H. Mashhadizadeh
    M. Ghobadi
    S. Jalilian