Closed Loop Control of Blood Glucose Level with Neural Network Predictor for Diabetic Patients

被引:0
|
作者
Bamgbose, Samuel Oludare [1 ]
Li, Xiangfang [1 ]
Qian, Lijun [1 ]
机构
[1] Texas A&M Univ Syst, Prairie View A&M Univ, Dept Elect & Comp Engn, Prairie View, TX 77446 USA
基金
美国国家科学基金会;
关键词
Diabetes; Blood Glucose Prediction; Insulin Pump; Neural Network; Glycemic Control; INSULIN DELIVERY;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Despite the recent advancements in glycemic control for diabetic patients, the realization of an automated closed-loop artificial pancreas is still a challenge. The purpose of this research is to develop an integrated control system for in silico closed loop administration of insulin for Type 1 diabetic patients based on patients' medical record and real-time control-relevant data. The proposed system consists of a virtual patient model from the online AIDA diabetes simulator, a neural network predictor trained on patients' data for feedback purposes, and a Proportional-Integral Controller and data logging nodes. The virtual patient takes into account the delayed and time-varying insulin and carbohydrate absorption rate associated with the existing subcutaneous insulin delivery and complex glucose metabolism, respectively. The neural network predictor was trained using 23 features including semi-static and dynamic data, with built-in knowledge of all available past blood glucose levels. Then the controller calculates the infusion bolus to be delivered by the insulin pump. Extensive simulations are performed and it is shown that the neural network predictor has less Root-Mean-Square error than the currently used continuous glucose monitors, which takes measurement from the interstitial fluid. Simulation results also demonstrate that our proposed data-driven closed loop system for glycemic control can effectively regulate the blood glucose level of Type 1 diabetic patients without hypoglycemic excursions, and with no preset instruction on meal ingestion.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Closed loop glucose control of diabetic rats
    Taylor, M. J.
    Tanna, S.
    Sahota, T.
    Sawicka, K.
    [J]. JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 : A15 - A15
  • [2] An approach to control the blood glucose level in diabetic patients
    Ionescu, C.
    Zlate, S.
    De Keyser, R.
    [J]. 2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 1, PROCEEDINGS, 2006, : 48 - +
  • [3] Closed loop blood glucose control in diabetics
    Faiz-Ul-Hassan
    Adil, Muhammad
    Khaqan, Ali
    Shuja, Sana
    Tiwana, Moazzam Islam
    Qadeer-ul-Hassan
    Malik, Shahzad
    Riaz, Raja Ali
    [J]. BIOMEDICAL RESEARCH-INDIA, 2017, 28 (16): : 7230 - 7236
  • [4] Knowledge-based Closed-loop Control of Blood Glucose Concentration in Diabetic Patients and Comparison with H∞ Control Technique
    Yasini, Sholeh
    Karimpour, Ali
    Sistani, Mohammad Bagher Naghibi
    [J]. IETE JOURNAL OF RESEARCH, 2012, 58 (04) : 328 - 336
  • [5] CLOSED-LOOP AND OPEN-LOOP DEVICES FOR BLOOD-GLUCOSE CONTROL IN NORMAL AND DIABETIC SUBJECTS
    SANTIAGO, JV
    CLEMENS, AH
    CLARKE, WL
    KIPNIS, DM
    [J]. DIABETES, 1979, 28 (01) : 71 - 81
  • [6] Closed-loop control of blood glucose levels in critically ill patients
    Chee, F
    Fernando, T
    van Heerden, PV
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (03) : 295 - 307
  • [7] Blood Glucose Level Prediction with Minimal Inputs Using Feedforward Neural Network for Diabetic Type 1 Patients
    Asad, Muhammad
    Qamar, Usman
    Zeb, Babar
    Khan, Aimal
    Khan, Younas
    [J]. ICMLC 2019: 2019 11TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND COMPUTING, 2019, : 182 - 185
  • [8] Controlling blood glucose levels in diabetics by neural network predictor
    Baghdadi, Golnaz
    Nasrabadi, Ali Motie
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3216 - 3219
  • [9] NEURAL CONTROL OF BLOOD-GLUCOSE LEVEL
    NIIJIMA, A
    [J]. JAPANESE JOURNAL OF PHYSIOLOGY, 1986, 36 (05): : 827 - 841
  • [10] PORTABLE CLOSED-LOOP FEEDBACK-SYSTEM FOR CONTROL OF THE BLOOD-GLUCOSE LEVEL IN THE PIG
    PIERZYNOWSKI, SG
    HAKANSSON, H
    LJUNGGREN, L
    MARTENSSON, L
    OLSSON, L
    [J]. ARTIFICIAL ORGANS, 1990, 14 (02) : 118 - 121