A new double-ended algorithm for fault location in an integrated power system (IPS) is presented. This method can be applied to real-time fault location because of its simplicity and its ability to self-synchronize. Experimental tests have been undertaken on both ac and dc power systems and both hard (step) faults and restriking transient faults (bouncing faults) have been investigated. The method is also shown to work in the presence of nonlinear loads. The performance of the proposed algorithm has been compared with a common synchronized double-ended fault-location method.
引用
收藏
页码:594 / 603
页数:10
相关论文
共 50 条
  • [1] A New Single-Ended Fault-Location Scheme for Utilization in an Integrated Power System
    Jia, Ke
    Thomas, David
    Sumner, Mark
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 38 - 46
  • [2] An PMU double ended fault location scheme for aged power cables
    El Din, EST
    Gilany, M
    Abdel Aziz, MM
    Ibrahim, DK
    [J]. 2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 80 - 86
  • [3] Frequency domain double-ended method of fault location for transmission lines
    Faybisovich, V.
    Khoroshev, M. I.
    [J]. 2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 941 - +
  • [4] Fault-Location Scheme for Power Distribution System with Distributed Generation
    Alwash, Shamam Fadhil
    Ramachandaramurthy, Vigna K.
    Mithulananthan, Nadarajah
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1187 - 1195
  • [5] Extended Fault-Location Formulation for Power Distribution Systems
    Salim, Rodrigo Hartstein
    Resener, Mariana
    Filomena, Andre Daros
    Caino de Oliveira, Karen Rezende
    Bretas, Arturo Suman
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (02) : 508 - 516
  • [6] Fault-location Observability Analysis on Power Distribution Systems
    Xiu, Wanjing
    Liao, Yuan
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (16) : 1862 - 1871
  • [7] A double-ended third harmonic method for vegetation high impedance fault location in overhead distribution systems
    Gallas, Mairon
    Farias, Patrick Escalante
    Wontroba, Aldair
    Morais, Adriano Peres
    Vieira, Joa Paulo Abreu
    Rossini, Jean Pereira
    Junior, Ghendy Cardoso
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2024, 231
  • [8] Impact of an inverter-based DG on a double-ended fault location method
    Jahanger, Hayder K.
    Thomas, David W. P.
    Sumner, Mark
    Rose, Christopher
    [J]. JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1078 - 1083
  • [9] Integrated electrics for TESO's new double-ended ferry
    不详
    [J]. NAVAL ARCHITECT, 2005, : 16 - 16
  • [10] Enhanced Fault-Location Scheme for Double Wye Shunt Capacitor Banks
    Jouybari-Moghaddam, H.
    Sidhu, Tarlochan S.
    Zadeh, Mohammad R. Dadash
    Parikh, Palak P.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1872 - 1880