Detection of pneumolysin in human urine using an immunosensor on screen-printed carbon electrodes

被引:13
|
作者
Díaz-González, M [1 ]
González-García, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Fac Quim, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
关键词
immunosensor; alkaline phosphatase; 3-indoxyl phosphate; screen-printed carbon electrode; streptavidin-biotin reaction; pneumolysin;
D O I
10.1016/j.snb.2005.04.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A voltammetric immunosensor for pneumolysin (PLY), based on the electrochemical detection of indigo blue, produced by alkaline phosphatase (AP) when 3-indoxyl phosphate (3-IP) is used as enzymatic substrate, is prepared and evaluated for measuring this toxin in human urine samples. The single-use immunosensor is fabricated by deposition of biotinylated anti-PLY monoclonal antibodies onto pre-oxidised streptavidin coated screen-printed carbon electrodes (SPCEs). Rabbit polyclonal IgGs anti-PLY are used in combination with an anti-rabbit IgG alkaline phosphatase conjugate as detection antibodies. The estimated limit of detection of the purified recombinant toxin is 0.05 ng/ml in Tris-buffer and 0.12 ng/ml in undiluted urine samples, but the same linear range, between 0.25 and 5.0 ng/ml, is obtained in both cases. The immunosensor is also applied to detect pneumolysin in urine samples from two pneumococcal pneumonia patients. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [1] Immunosensor for Mycobacterium tuberculosis on screen-printed carbon electrodes
    Díaz-González, M
    González-García, MB
    Costa-García, A
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (10): : 2035 - 2043
  • [2] Electrochemical immunosensor for the detection of staphylococcal enterotoxin B using screen-printed electrodes
    Sharma, Arun
    Rao, Vepa Kameswara
    Kamboj, Dev Vrat
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2020, 59 (02): : 174 - 180
  • [3] Celiac disease detection using a transglutaminase electrochemical immunosensor fabricated on nanohybrid screen-printed carbon electrodes
    Neves, Marta M. P. S.
    Gonzalez-Garcia, Maria Begona
    Nouws, Henri P. A.
    Costa-Garcia, Agustin
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 95 - 100
  • [4] Screen-Printed Carbon Electrodes for the Detection of Boldenone
    Kaur, Rameeta
    Khan, Aamir Amanat Ali
    Dennis, John Ojur
    Abdullah, Mohd Azmuddin
    [J]. PROCESS AND ADVANCED MATERIALS ENGINEERING, 2014, 625 : 809 - +
  • [5] An electrochemical immunosensor for testosterone using functionalized magnetic beads and screen-printed carbon electrodes
    Eguilaz, Marcos
    Moreno-Guzman, Maria
    Campuzano, Susana
    Gonzalez-Cortes, Araceli
    Yanez-Sedeno, Paloma
    Pingarron, Jose M.
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 517 - 522
  • [6] Disposable amperometric immunosensor for the detection of 17-β estradiol using screen-printed electrodes
    Butler, D
    Guilbault, GG
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 692 - 699
  • [7] A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen
    Yan, Mei
    Zang, Dejin
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 355 - 361
  • [8] Indirect Amperometric Detection of Glucose in Simulated Urine Using Screen-Printed Electrodes
    Huseinov, Artur
    Alvarez, Noe T.
    [J]. JOURNAL OF CHEMICAL EDUCATION, 2024, 101 (03) : 1139 - 1145
  • [9] Development of an immunosensor for the determination of rabbit IgG using streptavidin modified screen-printed carbon electrodes
    Díaz-González, M
    Hernández-Santos, D
    González-García, MB
    Costa-García, A
    [J]. TALANTA, 2005, 65 (02) : 565 - 573
  • [10] Disposable amperometric immunosensor for the detection of polycyclic aromatic hydrocarbons (PAHs) using screen-printed electrodes
    Fähnrich, KA
    Pravda, M
    Guilbault, GG
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (01): : 73 - 82