Biocomposite Suture Anchors Remain Visible Two Years After Rotator Cuff Repair

被引:7
|
作者
Sgroi, Mirco [1 ]
Friesz, Theresa [1 ]
Schocke, Michael [1 ]
Reichel, Heiko [1 ]
Kappe, Thomas [1 ]
机构
[1] Univ Ulm, Dept Orthopaed Surg, RKU, Ulm, Germany
关键词
L-LACTIC ACID; LONG-TERM ABSORPTION; BIOABSORBABLE ANCHORS; ROW; QUESTIONNAIRE; FIXATION; IMPLANTS; SCREWS;
D O I
10.1097/CORR.0000000000000665
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Biocomposite suture anchors containing osteoconductive materials have gained popularity in rotator cuff repairs. However, little is known about the influence of the addition of osteoconductive materials on implant resorption, bone reaction, tendon healing, and clinical outcomes scores. Questions/purposes (1) What percentage of suture anchors were not completely resorbed 2 years after implantation? (2) What are the diameters of the bone bed in relation to the implant? (3) Is tendon integrity correlated with bone tunnel diameter? (4) Is there an association between tunnel widening, periimplant fluid film grade, biodegradation grade, and retear with clinical outcomes scores, such as the Western Ontario Rotator Cuff Index (WORC) and the Oxford Shoulder Score (OSS)? Methods Thirty-six patients were enrolled from August 2012 to January 2014. The following inclusion criteria were applied: (1) reparable full-thickness supraspinatus tendon tears, (2) double-row suture bridge techniques applied for supraspinatus repair, (3) use of biocomposites suture anchor implants composed of poly L-lactic acid (PLLA) and beta-tricalcium phosphate (TCP) exclusively, and (4) a minimum of 2 years followup. Four patients met the exclusion criteria, and seven of 36 patients (19%) were lost to followup. Thereby, 25 patients (84 implants) were included in this retrospective study. To answer the study's questions, the following methods were applied: (1) The resorption of the implants and periimplant fluid film were assessed on MRI using a four-stage scale system, (2) bone bed diameter was measured on MRI at three different points on the longitudinal central axis of each anchor, (3) tendon integrity was evaluated on MRI according to the Sugaya classification and correlated to bone tunnel diameter, and (4) assessed tunnel diameters, periimplant fluid film grade, biodegradation grade, and tendon condition were related to clinical outcomes scores at the time of followup (2.3 +/- 0.3 years). The intra-observer reliability was 0.981 (p < 0.001) and interobserver reliability was 0.895 (p < 0.001). Results At 2.3 +/- 0.3 years, most analyzed suture anchors (76 of 84 [90%]) were, with varying degrees of degradation, still visible. Bone tunnels showed minor widening (0.4 +/- 1.4 mm) at the base, but osseous ingrowth was detected as narrowing at the middle (0.1 +/- 1.1 mm) and at the apex (1.4 +/- 1.7 mm) of the implants. Patients with retears (Sugaya Grades 4-5) had narrower tunnels (3.6 +/- 1.8 mm) than patients without retears (Sugaya Grades 1-3; 4.4 +/- 1.6 mm; mean difference, 0.782 [95% confidence interval {CI}: 0.009-1.6]; p = 0.050). WORC and Oxford scores were not associated with the tunnel widening amount, fluid film grade, biodegradation grade, or tendon retear. Conclusions In light of the results of the present study, surgeons should consider in their daily practice that the resorption process of these implants may be slower than assumed so far, but no association with severe implant-related complications has been found in the short term. Future studies should focus on the evaluation of the effects of osteoconductive materials on resorption, tendon healing, and clinical outcomes in the long term and on the integration process in different rotator cuff reconstruction techniques.
引用
收藏
页码:1469 / 1478
页数:10
相关论文
共 50 条
  • [1] CORR Insights®: Biocomposite Suture Anchors Remain Visible Two Years After Rotator Cuff Repair
    Duralde, Xavier Ampuero
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (06) : 1479 - 1481
  • [2] Perianchor Cyst Formation Around Biocomposite Biodegradable Suture Anchors After Rotator Cuff Repair
    Kim, Sae Hoon
    Kim, Do Yeon
    Kwon, Ji Eun
    Park, Ji Soon
    Oh, Joo Han
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (12): : 2907 - 2912
  • [3] Suture anchors in arthroscopic rotator cuff repair
    George, MS
    Kuhn, JE
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 210 - 214
  • [4] The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair ALL-SUTURE, POLYETHERETHERKETONE, AND BIOCOMPOSITE ANCHORS
    Kim, S. H.
    Yang, S. H.
    Rhee, S-M
    Lee, K. J.
    Kim, H. S.
    Oh, J. H.
    [J]. BONE & JOINT JOURNAL, 2019, 101B (12): : 1506 - 1511
  • [5] A biomechanical evaluation of suture anchors in repair of the rotator cuff
    Rossouw, DJ
    McElroy, BJ
    Amis, AA
    Emery, RJH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 458 - 461
  • [6] Metal and plastic suture anchors for rotator cuff repair
    Ritchie, PK
    McCarty, EC
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 215 - 220
  • [7] The Evolution of Suture Anchors in Arthroscopic Rotator Cuff Repair
    Denard, Patrick J.
    Burkhart, Stephen S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (09): : 1589 - 1595
  • [8] Arthroscopic revision surgery after arthroscopic rotator cuff repair with suture anchors
    Halbgewachs, J.
    Buess, E.
    [J]. ARTHROSKOPIE, 2008, 21 (03) : 138 - 144
  • [9] Pullout strength of suture anchors used in rotator cuff repair
    Tingart, MJ
    Apreleva, M
    Zurakowski, D
    Warner, JP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11): : 2190 - 2198
  • [10] Design determines functionality of suture anchors used for rotator cuff repair
    Stehle, J.
    Campbell, M.
    McMahon, P. J.
    Debski, R. E.
    [J]. CYTOTHERAPY, 2006, 8 : 65 - 65