摘要
A calorimeter for measuring the energy of pulsed microwave radiation with a duration from several ns to 1 s is described. Its operation principle is based on the absorption of radiation by a polar liquid and its expansion into a capillary. The energy Q is measured in the range from 1 mJ to 100 J. The minimum measurable energy density is about 3 mu J/cm(2). The coefficient of energy absorption ranges from 0.9 to 0.99 for radiation wavelengths from 7.5 to 13 and 2.4 to 3.5 cm. For Q in the range from 0.2 to 3 J, the absorbed energy is measured with an accuracy better than 1%.
引用
收藏
页码:70 / 72
页数:3
相关论文
共 50 条
  • [1] A liquid pulsed microwave radiation calorimeter
    A. L. Lisichkin
    E. V. Nesterov
    V. Yu. Petrov
    V. A. Stroganov
    [J]. Instruments and Experimental Techniques, 2007, 50 : 82 - 85
  • [2] A liquid pulsed microwave radiation calorimeter
    Lisichkin, A. L.
    Nesterov, E. V.
    Petrov, V. Yu.
    Stroganov, V. A.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2007, 50 (01) : 82 - 85
  • [3] Waveguide calorimeter for pulsed microwave radiation in the centimeter wavelength range
    Lisichkin, AL
    Nesterov, EV
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 362 - 364
  • [4] A pulsed ionizing radiation calorimeter
    M. D. Tarasov
    O. N. Petrushin
    Ya. A. Savel’ev
    M. Yu. Tarakanov
    Yu. S. Shigaev
    [J]. Instruments and Experimental Techniques, 2008, 51 : 489 - 490
  • [5] A pulsed ionizing radiation calorimeter
    Tarasov, M. D.
    Petrushin, O. N.
    Savel'ev, Ya. A.
    Tarakanov, M. Yu.
    Shigaev, Yu. S.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2008, 51 (03) : 489 - 490
  • [6] Development, optimization, and calibration of an active electromagnetic calorimeter for pulsed radiation spectrometry
    Stransky, V.
    Istokskaia, V.
    Versaci, R.
    Giuffrida, L.
    Cimmino, A.
    Margarone, D.
    Olsovcova, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2021, 16 (08)
  • [7] ABSORBED DOSE MEASUREMENT WITH A CALORIMETER IN A PULSED GAMMA-RADIATION FIELD
    KALLMEYER, DH
    KOHN, O
    ROOSE, UJ
    [J]. ATOMKERNENERGIE, 1974, 24 (03): : 203 - 207
  • [8] Radiation hazard assessment of pulsed microwave radars
    Puranen, L
    Jokela, K
    [J]. JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 1996, 31 (03) : 165 - 177
  • [9] BEHAVIORAL-EFFECTS OF PULSED MICROWAVE RADIATION
    HUNT, EL
    KING, NW
    PHILLIPS, RD
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1975, 247 (FEB28) : 440 - 453
  • [10] A MICROWAVE THERMISTOR CALORIMETER
    SMITH, MJ
    VAUGHAN, JRM
    [J]. JOURNAL OF SCIENTIFIC INSTRUMENTS, 1956, 33 (09): : 353 - 356