Antiarrhythmic effect of cardiac resynchronization therapy with triple-site biventricular stimulation

被引:21
|
作者
Ogano, Michio [1 ]
Iwasaki, Yu-ki [2 ]
Tanabe, Jun [1 ]
Takagi, Hisato [3 ]
Umemoto, Takuya [3 ]
Hayashi, Meiso [2 ]
Miyauchi, Yasushi [2 ]
Mizuno, Kyoichi [2 ]
机构
[1] Shizuoka Med Ctr, Div Cardiol, Shizuoka 4110906, Japan
[2] Nippon Med Sch, Dept Med, Div Cardiol Hepatol Geriatr & Integrated Med, Bunkyo Ku, Tokyo 1138603, Japan
[3] Shizuoka Med Ctr, Div Cardiovasc Surg, Shizuoka 4110906, Japan
来源
EUROPACE | 2013年 / 15卷 / 10期
关键词
Cardiac resynchronization therapy; Multi-site pacing; Ventricular arrhythmia; Antiarrhythmia; Ventricular repolarization; CONGESTIVE-HEART-FAILURE; VENTRICULAR PACING SITE; REPOLARIZATION; TACHYCARDIA; INCREASE; TRIAL; RISK;
D O I
10.1093/europace/eut134
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The antiarrhythmic effect of triple-site biventricular stimulation (Tri-V) is poorly understood. This study aims to evaluate the effect of cardiac resynchronization therapy (CRT) on ventricular arrhythmia (VA) with Tri-V using a single right ventricular (RV) and double left ventricular (LV) lead. Over a period of 3.5 years, 58 consecutive patients with New York Heart Association class IIIV heart failure, an LV ejection fraction of 0.35, and a QRS interval of 120 ms were enrolled. Acute haemodynamic responses to dual-site biventricular stimulation (Bi-V) and Tri-V were evaluated by assigning patients to a Bi-V or Tri-V group. Electrocardiogram parameters [QT interval, JT interval, and transmural dispersion of repolarization (TDR)] were measured over time after CRT. Spontaneous VA detected by telemetry was reviewed and confirmed. During a mean follow-up of 481 days after implantation, VA occurred in 2 of 22 patients in the Tri-V group and 14 of 36 patients in Bi-V group. Triple-site biventricular stimulation was thus associated with a decreased VA risk (P 0.044). Multivariate Cox analysis showed that Tri-V pacing prevented arrhythmic events as compared with Bi-V pacing (hazard ratio, 0.13; 95 confidence interval, 0.0290.610; P 0.009). Ventricular repolarization indices at 6 months were significantly shortened in Tri-V compared with Bi-V (QTc, 23.6 vs. 14.1, P 0.008; JTc, 21.4 vs. 7.7, P 0.005; TDRc, 39.9 vs. 17.0, P 0.001). Compared with Bi-V, Tri-V reduced VA during long-term follow-up. Improvements in repolarization parameters may result in antiarrhythmic effects.
引用
收藏
页码:1491 / 1498
页数:8
相关论文
共 50 条
  • [1] Antiarrhythmic Effect of Cardiac Resynchronization Therapy With Triple-site Biventricular Stimulation
    Ogano, Michio
    Iwasaki, Yu-ki
    Tanabe, Jun
    Takagi, Hisato
    Umemoto, Takuya
    Hayashi, Meiso
    Miyauchi, Yasushi
    Mizuno, Kyoichi
    [J]. CIRCULATION, 2012, 126 (21)
  • [2] Triple-site pacing in patients with biventricular device - Incidence of the phenomenon and cardiac resynchronization benefit
    Bulava, A
    Ansalone, G
    Ricci, R
    Giannantoni, P
    Pignalberi, C
    Heinc, P
    Lukl, J
    Santini, M
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 10 (01) : 37 - 45
  • [3] Triple-Site Pacing in Patients with Biventricular Device—Incidence of the Phenomenon and Cardiac Resynchronization Benefit
    Alan Bulava
    Gerardo Ansalone
    Renato Ricci
    Paride Giannantoni
    Carlo Pignalberi
    Petr Heinc
    Jan Lukl
    Massimo Santini
    [J]. Journal of Interventional Cardiac Electrophysiology, 2004, 10 : 37 - 45
  • [4] Electrical storm after cardiac resynchronization therapy suppressed by triple-site biventricular pacing and atrioventricular nodal ablation
    Itoh, Mitsuaki
    Yoshida, Akihiro
    Takei, Asumi
    Hirata, Ken-ichi
    [J]. HEART RHYTHM, 2012, 9 (12) : 2059 - 2062
  • [5] Better acute and chronic hemodynamic responses of cardiac resynchronization therapy with triple-site ventricular stimulation
    Ogano, M.
    Iwasaki, Y.
    Tanabe, J.
    Takagi, H.
    Umemoto, T.
    Hayashi, M.
    Miyauchi, Y.
    Shimizu, W.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 87 - 88
  • [6] Long-term outcome following cardiac resynchronization therapy with triple-site ventricular stimulation
    Ogano, M.
    Iwasaki, Y.
    Kawanaka, H.
    Tajiri, M.
    Tanabe, J.
    Hayashi, M.
    Shimizu, W.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 1166 - 1166
  • [7] Functional improvement after triple-site and conventional cardiac resynchronization therapy
    Lenarczyk, R.
    Kowalski, O.
    Kukulski, T.
    Pruszkowska-Skrzep, P.
    Sokal, A.
    Szulik, M.
    Zielinska, T.
    Kowalczyk, J.
    Pluta, S.
    Kalarus, Z.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 810 - 810
  • [8] Safety, feasibility, and outcome results of cardiac resynchronization with triple-site ventricular stimulation compared to conventional cardiac resynchronization
    Anselme, Frederic
    Bordachar, Pierre
    Pasquie, Jean Luc
    Klug, Didier
    Leclercq, Christophe
    Milhem, Antoine
    Alonso, Christine
    Deharo, Jean Claude
    Gras, Daniel
    Probst, Vincent
    Piot, Olivier
    Savoure, Arnaud
    [J]. HEART RHYTHM, 2016, 13 (01) : 183 - 189
  • [9] Triple site biventricular pacing in patients undergoing cardiac resynchronization therapy
    Lenarczyk, R.
    Kowalski, O.
    Kukulski, T.
    Szulik, M.
    Pruszkowska-Skrzep, P.
    Zielinska, T.
    Pluta, S.
    Sredniawa, B.
    Musialik-Lydka, A.
    Kalarus, Z.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 294 - 294
  • [10] Triple-site cardiac resynchronization therapy in patients with heart failure - the prospective, randomized trial
    Lenarczyk, R.
    Kowalski, O.
    Sredniawa, B.
    Pruszkowska-Skrzep, P.
    Pluta, S.
    Sokal, A.
    Szulik, M.
    Kukulski, T.
    Zielinska, T.
    Kalarus, Z.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 145 - 145